What a Pulse Reed Switch Adds to a Water Meter

Power Required
None, passive switch
Volume Per Pulse
Determined by the water meter it is fitted to
Volume per pulse is set by the meter
Netafim meters ship in different pulse values, so check the register before you scale readings.
Kaynak referans fiyatıTRY 3,565.48

Sadece karşılaştırma amaçlıdır. Güncel toptan fiyatınızı, stok durumunu ve teslimat koşullarını talep edin.

Ödeme gerekmiyor. İhtiyaçlarınız hakkında bir görüşme.

Fabrikadan doğrudan destek15 yılı aşkın deneyim
DAHA YAKINDAN BAKALIM

Bu ürün hakkında biraz daha bilgi

What a Pulse Reed Switch Adds to a Water Meter

Product details

  • A mechanical meter counts perfectly well and tells nobody.
  • This register sits on the meter and adds an electrical output.
  • No power is needed on the meter side, because the switch is passive.
  • Reading the Water Meter Pulse Output at the Controller
  • Any controller, datalogger or PLC with a digital input can take it, which is what makes a water meter pulse output so portable across equipment.
  • The controller does the arithmetic: count the pulses, multiply by the volume each pulse represents, and you have consumption.
  • That multiplier is set by the meter rather than by the switch, and Netafim meters are supplied in different pulse values.
  • Check the register on the meter you are fitting, because getting that number wrong scales every reading you log.
  • Two practical notes.
  • Reed contacts are mechanical and they do eventually wear, which is the usual reason one gets replaced rather than a fault in the meter itself.
  • And run the signal pair away from pump and light wiring, since a long unshielded run beside a contactor can pick up false counts.
  • Passive, no power needed: The switch takes nothing on the meter side.
  • The controller supplies the sensing circuit.
  • Volume per pulse is set by the meter: Netafim meters ship in different pulse values, so check the register before you scale readings.
  • A common replacement part: Reed contacts are mechanical and wear, which is usually why one is swapped.
  • Keep the run clean: Route the signal pair away from pump and lighting wiring to avoid false counts.
  • Technical Specifications

Teknik Özellikler

Power Required
None, passive switch
Volume Per Pulse
Determined by the water meter it is fitted to
Volume per pulse is set by the meter
Netafim meters ship in different pulse values, so check the register before you scale readings.

Bunu projeniz için işe yarar hale getirelim.

Siparişinizde miktar, teslimat adresi, yetiştirme bölgesi ve varsa voltaj veya fiş gereksinimlerinizi belirtin. Özellikler, stok durumu, nakliye ve garanti koşulları yazılı teklifinizde teyit edilecektir.

Kaydedilen döviz kuru kullanılarak yapılan referans dönüşümü. 15 Kas 2026. Dönüştürülen tutarlar bir fiyat teklifi değildir.

BİRLİKTE BÜYÜYELİM

Sorular ve tartışma

0

Bir sorunuz mu var veya paylaşmak istediğiniz faydalı bir şey mi? Sohbeti başlatın.

KEŞFETMEYE DEVAM EDİN

Mekanınız için daha fazla olanak

Tüm ürünleri görüntüle
İYİ BİR ŞEYİN BAŞLANGICI

Projenizi gün ışığına çıkaralım.

İhtiyaçlarınız hakkında bize biraz bilgi verin. Verdiğiniz bilgiler doğrultusunda size uygun bir toptan satış teklifi hazırlayacağız.

Ürün listeniz

Ödeme yok. Yükümlülük yok. Sadece faydalı bir sohbet.