How a Two Outlet Temperature and Humidity Controller Divides the Work
Product details
- One outlet for the condition you are heating or cooling, one for the condition you are wetting or drying.
- That split is the whole design, and it is why this unit replaces two separate single task controllers.
- Each outlet has its own target, so a heater and a dehumidifier stop fighting each other for the same reading.
- It runs cooling, heating, humidifying, dehumidifying, or cooling and dehumidifying together.
- Electrically it is 120 volts at 15 A, with a total load ceiling of 2 HP across both outlets.
- That ceiling is the number to check first, because two large machines will exceed it long before the outlets do.
- Day and night detection is built in, and each period carries its own pair of set points.
- Operation priority is adjustable, which decides what happens when both conditions call at once.
- So is the shutdown delay, which is what keeps a compressor from restarting into its own back pressure.
- Why the External Probe Placement Decides Your Readings
- An external probe on a lead is the reason this unit reads the room instead of reading itself.
- A controller with the sensor inside its own case sits on a wall warmed by whatever is behind it.
- Accuracy is plus or minus one degree Celsius on temperature and plus or minus 3.5 percent on relative humidity.
- Those tolerances only hold where the probe hangs in moving air at canopy height.
- Put it in the middle of the space, out of the discharge of anything it switches, and clear of the lights.
- A probe in a dehumidifier's exhaust will hold the room far wetter than the display claims.
- The four equipment version of this controller is a separate unit.
- Anyone who needs to add carbon dioxide control needs a different model again.
- This one does two jobs properly rather than four approximately.
- Outlets: Two, one for temperature equipment and one for humidity
- Modes: Cooling, heating, humidifying, drying, or cooling with drying
- Probes: Both readings from external sensors on a lead
- Temperature accuracy: Plus or minus one degree Celsius
- Humidity accuracy: Plus or minus 3.5 percent relative humidity
- Electrical: 120 volts, 15 A, 2 HP total load
- Day and night: Detected automatically, with its own set points each
- Adjustable: Operation priority and shutdown delay
- Bigger version: A four equipment model exists as a separate unit
ข้อกำหนด
- Model
- iGS-110
- Type
- Combined temperature and relative humidity controller
- Equipment controlled
- Two, on separate outlets
- Temperature sensor
- External probe, accuracy plus or minus 1 degree Celsius
- Humidity sensor
- External probe, accuracy plus or minus 3.5 percent
- Voltage
- 120 V
- Current
- 15 A
- Larger model
- The four equipment version is a separate product
- Temperature accuracy
- Plus or minus one degree Celsius
- Humidity accuracy
- Plus or minus 3.5 percent relative humidity