Product details
- The range runs -2.0 to 16.0 pH at 0.1 resolution and ±0.1 accuracy, with temperature from -5 to 60 °C.
- Readings are temperature compensated automatically.
- The sensor is an HI73127 cartridge that unscrews and replaces, which is the difference between a five year tool and a disposable one.
- Four cells run it for roughly 300 hours and it shuts off after eight idle minutes.
- The casing is waterproof and it floats.
- Living With a pH and Temperature Tester That Reads in Tenths
- Calibration is automatic, one point or two, against the 4.01 and 7.01 buffers that come in the box.
- Storage solution comes with it as well, and that is where the tip belongs between readings.
- Never dry, and never parked in plain water, which strips the junction.
- The resolution is the trade-off.
- Steps this size are coarse for reservoir work, where the gap between 5.8 and 6.0 changes what a root can actually take up.
- Use it for spot checks, runoff and source water.
- When you are dialling a tank, the HI98129 combo reads to 0.01 and adds EC on the same pen.
- 0.1 pH resolution: Tenths, which suits spot checks and source water rather than fine reservoir work.
- 2.0 to 16.0 pH range: Wide enough for cleaning solutions and nutrient stock as well as feed water.
- Replaceable HI73127 cartridge: A spent electrode costs a cartridge, not a meter.
- Automatic temperature compensation: Temperature reads alongside pH and corrects it, so a cold tank does not mislead.
- Automatic calibration: One or two point against the 4.01 and 7.01 buffers supplied.
- About 300 hours on four cells: With a battery level indicator and shutdown after eight idle minutes.
- Waterproof, and it floats: Dropping it in the reservoir is an inconvenience, not a replacement.
- Step up if you need finer: The HI98129 combo reads 0.01 pH and adds EC and TDS on one pen.
- Technical Specifications
ข้อกำหนด
- Type
- pH and temperature tester
- pH Range
- -2.0 to 16.0 pH
- pH Resolution
- 0.1 pH
- pH Accuracy
- ±0.1 pH at 25 °C
- pH Calibration
- Automatic, one or two point, two sets of standard buffers
- Temperature Range
- -5.0 to 60.0 °C, 23.0 to 140.0 °F
- Temperature Resolution
- 0.1 °C
- Temperature Accuracy
- ±0.5 °C
- Temperature Compensation
- Automatic
- Dimensions
- 163 x 40 x 26 mm
- Weight
- 100 g, 3.5 oz
- Finer Resolution Option
- HI98129 combo, 0.01 pH, plus EC and TDS
- Automatic temperature compensation
- Temperature reads alongside pH and corrects it, so a cold tank does not mislead.
- Automatic calibration
- One or two point against the 4.01 and 7.01 buffers supplied.