Netafim Backflush Controller, 2 Outputs With DP Sensor, 24VAC, With Mounting Bracket
Модель / Артикул: 00105-006200
Netafim Backflush Controller 24VAC for Mains-Powered Filter Pairs
- Power Source
- 110 or 220 VAC, 50 or 60 Hz, internal transformer to 24VAC
- Dimensions
- 9-1/2 in H x 5-5/8 in L x 3-1/4 in D
- Model
- 31NBCAC2
- Outputs
- 2, 24VAC solenoids
Только для сравнения. Запросите актуальную оптовую цену, наличие товара и условия доставки.
Оплата не требуется. Обсуждение ваших потребностей.
Немного подробнее об этом продукте
Netafim Backflush Controller 24VAC for Mains-Powered Filter Pairs
Product details
- Where a filter pair sits beside the pump house, mains power is the simplest supply for its flushing valves.
- The Netafim 31NBCAC2, item 00105-006200, takes 110 or 220 volts AC through an internal transformer.
- That transformer produces the 24VAC that operates the solenoids on its 2 outputs.
- Its embedded electronic sensor reads the pressure drop across the filters and starts a flush at the chosen set point.
- Netafim allows a set point anywhere from 0.1 to 2.0 bar, with the display in bar or psi.
- A timed interval can run alongside, so whichever comes first starts the sequence.
- The modular board takes plug-in cards of two outputs each, up to 10 in total.
- Automatic disc, sand media and screen filters can all be run from it.
- A mounting bracket comes in the box, and the housing weighs just 1.3 lb.
- The LCD shows flush time, DP set point, actual DP and the flush mode on one screen.
- Programming a Two Filter Flush Controller
- Four keys handle all programming: ENTER, minus, plus and MANUAL.
- Pressing ENTER puts the first field into edit mode, and each further press moves to the next field.
- Flush time per station can be as short as 5 seconds or as long as 6 minutes.
- Hold ENTER for at least 3 seconds to reach the configuration menu.
- There the unit detects how many plug-in boards are fitted and assigns outputs from number 1 upward.
- Answering yes to Main Valve unlocks a pre-dwell between that valve opening and the first filter flushing.
- Pre-dwell steps run from 5 seconds to 6 minutes, so pressure can build before the first station opens.
- A looping limit of 1 to 10 consecutive DP cycles flags a filter that is not coming clean.
- For zero calibration, disconnect both sensor ports so they read atmospheric pressure, then select Yes.
- Pressing MANUAL starts a sequence on demand, and pressing it again ends one in progress.
- 24VAC outputs from mains: Internal transformer accepts 110 or 220 VAC, 50 or 60 Hz.
- Two backflush outputs: Expandable in two-output plug-in cards to a total of 10.
- Embedded DP sensor: Set point 0.1-2.0 bar (1-30 psi), shown in bar or psi.
- Four-key LCD programming: ENTER, minus, plus and MANUAL keys.
- Main valve and pre-dwell: Optional main or pressure sustaining valve with pre-dwell up to 6 minutes.
- Looping alarm: Detects repeated DP cycles past a 1-10 limit.
- Technical Specifications
Технические характеристики
- Model
- 31NBCAC2
- Outputs
- 2, 24VAC solenoids
- Power Source
- 110 or 220 VAC, 50 or 60 Hz, internal transformer to 24VAC
- Operating Temperature
- 32-140°F (0-60°C)
- Dimensions
- 9-1/2 in H x 5-5/8 in L x 3-1/4 in D
- Weight
- 1.3 lb
- Two backflush outputs
- Expandable in two-output plug-in cards to a total of 10.
Давайте это используем в вашем проекте.
В запросе укажите необходимое количество, место доставки, регион выращивания, а также требуемое напряжение и тип вилки. Технические характеристики, наличие, условия доставки и гарантии будут подтверждены в вашем письменном предложении.
Конвертация с использованием сохраненного обменного курса на определенную дату. 15 нояб. 2026 г.. Указанные суммы в пересчете не являются ценовым предложением.
Больше возможностей для вашего пространства
Yield Lab Heat Mat Thermostat Temperature Controller
Вопросы и обсуждение
У вас есть вопрос или что-то полезное, чем вы хотите поделиться? Начните разговор.