Данный контент в настоящее время доступен на языке оригинала.
Growlink SI Pulse Module
Модель / Артикул: BMT-F-SI4 BACnet MS/TP
4-Channel BACnet MS/TP Pulse Counter Module for Flow Meters
- Inputs
- 4 × S0 pulse, DIN EN 62053-31 Class A
- Supply voltage
- 24 V AC/DC
- Mounting
- TH35 DIN rail (IEC 60715)
- Configuration
- 2 front rotary switches (address + bit rate)
Только для сравнения. Запросите актуальную оптовую цену, наличие товара и условия доставки.
Оплата не требуется. Обсуждение ваших потребностей.
Немного подробнее об этом продукте
4-Channel BACnet MS/TP Pulse Counter Module for Flow Meters
Product details
- The BMT-F-SI4 carries four S0 inputs that meet DIN EN 62053-31 Class A.
- BACnet MS/TP reports the rolling count back to the Growlink controller.
- The software converts pulses to gallons per minute, then trims pump runtime to land the exact injection volume each dose calls for.
- BACnet MS/TP S0 Input with Retentive Counters and 500 Hz Capture
- Pulse capture runs at 50 Hz through the Accumulator object and 500 Hz through the PulseConverter object.
- A high-pulse flow meter on a fast-cycling pump stays accurate.
- Retentive memory holds the last counter reading through a power blip.
- That matters when a recipe spans a UPS swap or breaker trip.
- Address and bit rate set with two rotary switches on the front.
- A new module drops onto an existing trunk without bringing the BACnet line up on a laptop.
- 4 × S0 pulse inputs (DIN EN 62053-31 Class A): Plug any S0-output flow or energy meter into the module.
- BACnet MS/TP over a single trunk: Reports counter values back to the Growlink controller and any other BACnet client without protocol gateways.
- 50 Hz Accumulator / 500 Hz PulseConverter: Two BACnet objects cover slow utility meters and fast injection-pump feedback on the same module.
- Retentive counter memory: Saves the last reading on power loss, so the recipe picks up the correct gallons after a panel cycle.
- 2 front-panel rotary switches: Set BACnet address and bit rate without a laptop or DIP-switch acrobatics.
- 24 V AC/DC supply with spring-clamp terminals: Pairs with the same low-voltage bus that runs the rest of the BMT-F I/O lineup.
- TH35 DIN rail mount: IEC 60715 rail snap-in keeps panels tidy alongside BMT-F-TO4, BMT-F-AOP4, or BMT-F-RTR.
- Technical Specifications
Технические характеристики
- Inputs
- 4 × S0 pulse, DIN EN 62053-31 Class A
- Supply voltage
- 24 V AC/DC
- Mounting
- TH35 DIN rail (IEC 60715)
- Configuration
- 2 front rotary switches (address + bit rate)
- Retentive counter memory
- Saves the last reading on power loss, so the recipe picks up the correct gallons after a panel cycle.
Давайте это используем в вашем проекте.
В запросе укажите необходимое количество, место доставки, регион выращивания, а также требуемое напряжение и тип вилки. Технические характеристики, наличие, условия доставки и гарантии будут подтверждены в вашем письменном предложении.
Конвертация с использованием сохраненного обменного курса на определенную дату. 15 нояб. 2026 г.. Указанные суммы в пересчете не являются ценовым предложением.
Больше возможностей для вашего пространства
‘Wood Lovr’ Organic Hardwood-Based Sterile Mushroom Substrate
‘Boomr Bag’ Manure-Based Sterile Mushroom Bulk Substrate
Вопросы и обсуждение
У вас есть вопрос или что-то полезное, чем вы хотите поделиться? Начните разговор.