Данный контент в настоящее время доступен на языке оригинала.
GF EC Probe (For NDS, NDK)
Модель / Артикул: 3-2850-52-41V
PVDF Conductivity Electrode for the Growlink Nutrient Doser System
- Output
- 4-20 mA, two-wire (eight pre-set ranges per cell)
- Process connection
- 3/4 in NPT
- Calibration
- EasyCal auto-recognition (±10% of standard solution)
- Compatibility
- Growlink Nutrient Doser System (NDS), Nutrient Doser Kit (NDK), Connect Controller, generic 4-20 mA PLC
Только для сравнения. Запросите актуальную оптовую цену, наличие товара и условия доставки.
Оплата не требуется. Обсуждение ваших потребностей.
Немного подробнее об этом продукте
PVDF Conductivity Electrode for the Growlink Nutrient Doser System
Product details
- The 2841 electrode pairs a PVDF insulator with 316 SS contacts and FKM internal O-rings.
- The wetted side handles standard hydroponic feeds without crazing.
- The 1.0 cell constant covers 10 to 10,000 µS — the band where fertigation EC actually sits.
- The 3/4 in NPT thread drops into any inline tee or submersion saddle.
- A 15-foot factory cable connects the electrode to the 2850 electronics.
- Up to 1,000 feet of cable runs between the electronics and the receiving controller.
- GF Signet 2850 Conductivity Sensor Electronics with EasyCal
- The 2850 is a two-wire transmitter that reports EC on a 4-20 mA loop.
- Eight pre-set ranges key to each cell constant — pick the band that matches your recipe and the loop scales automatically.
- EasyCal auto-recognizes a standard calibration solution within ±10% of its known value.
- A routine calibration takes a beaker of solution and a button press.
- The NEMA 4X / IP65 enclosure ignores wash-down and humidity.
- The 4-20 mA output lands on a Growlink Nutrient Doser, Connect Controller, or any PLC that reads a standard loop.
- 2841 PVDF electrode, 1.0 cell constant: 316 SS contacts and FKM O-rings handle 10 to 10,000 µS — the band fertigation actually lives in.
- 3/4 in NPT process connection: Threads into any standard inline tee or submersion saddle without an adapter.
- 4-20 mA two-wire output: Eight pre-set ranges per cell constant scale the loop to the recipe band.
- EasyCal auto-recognition: Beaker calibration with any standard solution within ±10% of the known value, no menu diving.
- NEMA 4X / IP65 enclosure: Sealed against wash-down and humid grow-room air on a wall or a mechanical-room shelf.
- Up to 1,000 ft electronics-to-controller cable run: Place the head where the line lives and the loop where the PLC can see it.
- Specified for Growlink NDS and NDK dosing systems: Drop-in EC sensor for the Nutrient Doser System and Nutrient Doser Kit.
- Technical Specifications
Технические характеристики
- Output
- 4-20 mA, two-wire (eight pre-set ranges per cell)
- Process connection
- 3/4 in NPT
- Calibration
- EasyCal auto-recognition (±10% of standard solution)
- Compatibility
- Growlink Nutrient Doser System (NDS), Nutrient Doser Kit (NDK), Connect Controller, generic 4-20 mA PLC
Давайте это используем в вашем проекте.
В запросе укажите необходимое количество, место доставки, регион выращивания, а также требуемое напряжение и тип вилки. Технические характеристики, наличие, условия доставки и гарантии будут подтверждены в вашем письменном предложении.
Конвертация с использованием сохраненного обменного курса на определенную дату. 15 нояб. 2026 г.. Указанные суммы в пересчете не являются ценовым предложением.
Больше возможностей для вашего пространства
‘Wood Lovr’ Organic Hardwood-Based Sterile Mushroom Substrate
‘Boomr Bag’ Manure-Based Sterile Mushroom Bulk Substrate
Вопросы и обсуждение
У вас есть вопрос или что-то полезное, чем вы хотите поделиться? Начните разговор.