Este conteúdo está disponível atualmente em seu idioma original.
Netafim Backflush Controller, 4 Outputs With DP Sensor, 12VDCL, With Mounting Bracket
Modelo / SKU: 00105-006260
Netafim 4 Output Backflush Controller on DC Power
- Power Source
- 4 x D alkaline (6V), 12V dry battery, or 12V rechargeable with 2 W solar panel
- Dimensions
- 9-1/2 in H x 5-5/8 in L x 3-1/4 in D
- Model
- 31NBCDCL4
- Outputs
- 4, 12VDC latching (2-wire)
Apenas para fins de comparação. Solicite seu preço de atacado atual, disponibilidade e condições de entrega.
Nenhum pagamento é necessário. Uma conversa sobre o que você precisa.
Um pouco mais sobre este produto
Netafim 4 Output Backflush Controller on DC Power
Product details
- Four automatic filters on one header need a flush sequence that can run unattended for weeks.
- Netafim model 31NBCDCL4, item 00105-006260, gives that header 4 outputs for 12VDC latching solenoids.
- It runs on DC power, from four D-size alkaline batteries, a 12 volt battery, or a rechargeable battery charged by a small solar panel.
- Each output sits on a plug-in board of two, and the controller counts the boards it finds at configuration.
- Outputs are handed to the backflush valves first, starting at number 1.
- An alarm, a delay valve and a main valve, if chosen, take the next outputs in that order.
- On this four-output unit, adding a main valve leaves three outputs for filters.
- Any unused last station can be cancelled with the M key.
- Netafim lists the controller for automatic disc, sand media and screen filters.
- A mounting bracket is supplied, and the housing measures 9-1/2 x 5-5/8 x 3-1/4 in.
- How the DP Sensor Filter Controller Handles Faults
- The embedded electronic sensor reads inlet and outlet pressure through two command tubes.
- Put a 120 mesh filter, installer-supplied, on the high-pressure tube before the red port.
- When consecutive DP-triggered cycles pass the looping limit, the controller declares an endless loop.
- It shows the fault, energizes the alarm output and stops treating DP as a trigger.
- Flushing then continues on the interval countdown alone until the constant DP signal clears.
- On a blank screen with a silent keypad, check that every battery is installed correctly.
- The Main Card needs 6 volts on this DC model.
- Cycle totals for DP, timed and manual flushes can each be cleared with the plus or minus key.
- Four 12VDC latching outputs: Two plug-in boards of two outputs each.
- DC, battery or solar supply: D alkaline cells, a 12V battery or a solar-charged rechargeable.
- Flexible output allocation: Alarm, delay valve and main valve take the outputs after the filters.
- Looping protection: Switches to time-only flushing and raises the alarm after repeated DP cycles.
- Mounting bracket: Included with the controller.
- Technical Specifications
Especificações
- Model
- 31NBCDCL4
- Outputs
- 4, 12VDC latching (2-wire)
- Power Source
- 4 x D alkaline (6V), 12V dry battery, or 12V rechargeable with 2 W solar panel
- Optional Outputs
- Alarm, delay valve, main / pressure sustaining valve
- Operating Temperature
- 32-140°F (0-60°C)
- Dimensions
- 9-1/2 in H x 5-5/8 in L x 3-1/4 in D
- Weight
- 1.3 lb
- Flexible output allocation
- Alarm, delay valve and main valve take the outputs after the filters.
- Looping protection
- Switches to time-only flushing and raises the alarm after repeated DP cycles.
- Mounting bracket
- Included with the controller.
Vamos fazer isso funcionar para o seu projeto.
Inclua a quantidade desejada, o local de entrega, a região de cultivo e quaisquer requisitos de voltagem ou tipo de plugue em sua solicitação. As especificações, a disponibilidade, os termos de envio e a garantia serão confirmados em seu orçamento por escrito.
Conversão de referência usando a taxa de câmbio salva com a data 15 de nov. de 2026. Os valores convertidos não constituem uma cotação.
Mais possibilidades para o seu espaço
Yield Lab Heat Mat Thermostat Temperature Controller
Perguntas e discussão
Tem alguma pergunta ou algo útil para compartilhar? Inicie a conversa.