Growlink Level Sensor (for Batch TankLINK)
Modelo / SKU: GL-LINK-LEVEL
Reading Tank Level with the Growlink Batch TankLINK Level Sensor
- Sensor Type
- Float / serpentine pontoon
- Output Signal
- 4–20mA analog
- Connector
- Molex (1× 4–20mA input on controller)
- Compatible Controller
- Growlink Batch TankLINK (alongside pH, EC, Temp inputs)
Apenas para fins de comparação. Solicite seu preço de atacado atual, disponibilidade e condições de entrega.
Nenhum pagamento é necessário. Uma conversa sobre o que você precisa.
Um pouco mais sobre este produto
Reading Tank Level with the Growlink Batch TankLINK Level Sensor
Product details
- The Growlink Batch TankLINK Level Sensor floats a serpentine pontoon directly in the nutrient tank.
- The pontoon's shape lets the assembly drop through narrow tank openings without disassembly.
- The transducer translates that movement into a 4–20mA signal.
- A Molex connector carries the signal to the controller's level input.
- That feed drives the TankLINK's refill logic and overfill alarms.
- The controller can call a fill pump on or trip an alert before the tank crosses either threshold.
- Wiring the TankLINK Level Sensor into the Same Tank as pH, EC, and Temp
- Most growers position this TankLINK level sensor in the same tank that already holds the pH, EC, and temperature probes.
- A single Batch TankLINK runs all four inputs from one board.
- The 4–20mA output is the standard analog type the controller's level input expects.
- The nutrient tank level sensor wires in with no protocol conversion.
- Plug-and-play installation keeps a sensor swap to a few minutes during tank teardown.
- Lift the pontoon, unplug the Molex, drop in the new unit, and the controller picks the reading back up at the next sample cycle.
- Tank cleaning between runs is the most common time to inspect the pontoon for scale buildup.
- A wipe with a soft cloth keeps the batch tank level sensor reading honest across the next harvest cycle.
- The continuous 4–20mA reading also pairs with the controller's logged history for season-over-season fill-rate analysis.
- That helps spot a slow leak or a clogged refill solenoid before the next crop suffers a dry-tank hour.
- 4–20mA Analog Output: Standard signal type wired straight into the Batch TankLINK controller's level input.
- Molex Connector Wiring: Plug-and-play swap during teardown — unplug, lift, replace, plug back in.
- Automated Refill + Overfill Logic: Feeds the controller's level thresholds for pump triggers and alert calls before the tank crosses either.
- Continuous Level Tracking: Real-time reading across the full tank stroke, not just point-level high/low switches.
- Technical Specifications
Especificações
- Sensor Type
- Float / serpentine pontoon
- Output Signal
- 4–20mA analog
- Connector
- Molex (1× 4–20mA input on controller)
- Compatible Controller
- Growlink Batch TankLINK (alongside pH, EC, Temp inputs)
- Molex Connector Wiring
- Plug-and-play swap during teardown — unplug, lift, replace, plug back in.
Vamos fazer isso funcionar para o seu projeto.
Inclua a quantidade desejada, o local de entrega, a região de cultivo e quaisquer requisitos de voltagem ou tipo de plugue em sua solicitação. As especificações, a disponibilidade, os termos de envio e a garantia serão confirmados em seu orçamento por escrito.
Conversão de referência usando a taxa de câmbio salva com a data 15 de nov. de 2026. Os valores convertidos não constituem uma cotação.
Mais possibilidades para o seu espaço
Yield Lab Heat Mat Thermostat Temperature Controller
Perguntas e discussão
Tem alguma pergunta ou algo útil para compartilhar? Inicie a conversa.