Growlink Batch TankLINK EC Sensor
Modelo / SKU: GL-LINK-ECSENSOR
Reading Conductivity with the Growlink Batch TankLINK EC Sensor
- EC Range
- 0–7,000 µS
- Temperature Compensation
- Built-in PT1000 element in cable
- Cable Length
- 10 ft (3 m); 30 ft available separately
- Calibration
- Single-point @ 1413 µS via LCD wizard
Apenas para fins de comparação. Solicite seu preço de atacado atual, disponibilidade e condições de entrega.
Nenhum pagamento é necessário. Uma conversa sobre o que você precisa.
Um pouco mais sobre este produto
Reading Conductivity with the Growlink Batch TankLINK EC Sensor
Product details
- The Growlink Batch TankLINK EC Sensor measures nutrient solution conductivity inside a batch tank in real time.
- The probe reads across a 0–7,000 µS range.
- Accuracy is ±20 µS below 2,000 µS and ±50 µS above that.
- Resolution is 2 µS — roughly 0.02 mS/cm in PPM-meter terms.
- A 10-foot cable runs from the probe to the Batch TankLINK controller's labeled screw terminal block.
- The cable also carries a PT1000 element that gives the controller automatic temperature compensation on every reading.
- Calibration is a single-point process at 1413 µS.
- Drop the probe into calibration solution alongside the temperature probe to lock in the cal pass.
- Wiring the TankLINK EC Probe into a Recirculation Loop
- Most batch-tank installs run a separate probe per recirculation loop.
- The 10-foot cable covers tanks within reach of the controller.
- The 30-foot option (available separately) handles longer runs where the controller mounts wall-side and the tank sits across the room.
- Pair the data with the TankLINK's automated dosing and refill triggers and the nutrient solution EC sensor holds the line to setpoint between batches.
- PT1000-compensated readings also mean morning EC checks match afternoon checks even when the room runs 8°F warmer under lights.
- Plug-and-play wiring keeps a single-probe swap during teardown to a few minutes.
- No driver shuffling — just the batch tank conductivity probe back into the terminal block and a fresh 1413 µS recalibrate.
- Most rooms swap the probe at the start of each season or when calibration drift crosses ±50 µS at the cal point.
- 0–7,000 µS Range: Covers the full PPM band growers feed across veg, transition, and bloom in one probe.
- Tiered Accuracy: ±20 µS below 2,000 µS and ±50 µS above — tight enough to catch real EC drift between feeds.
- Built-In PT1000 Compensation: The cable carries a temperature element so readings stay honest across an 8°F lights-on swing.
- 10 ft Cable Standard: Reaches most controller-to-tank layouts; a 30 ft version is available separately for longer runs.
- Single-Point Calibration: One 1413 µS solution and the LCD wizard handle the full cal — no two-point dance required.
- Technical Specifications
Especificações
- EC Range
- 0–7,000 µS
- Temperature Compensation
- Built-in PT1000 element in cable
- Cable Length
- 10 ft (3 m); 30 ft available separately
- Calibration
- Single-point @ 1413 µS via LCD wizard
- Connection
- Screw terminal block on Batch TankLINK transmitter
- Compatible Controller
- Growlink Batch TankLINK
- Single-Point Calibration
- One 1413 µS solution and the LCD wizard handle the full cal — no two-point dance required.
Vamos fazer isso funcionar para o seu projeto.
Inclua a quantidade desejada, o local de entrega, a região de cultivo e quaisquer requisitos de voltagem ou tipo de plugue em sua solicitação. As especificações, a disponibilidade, os termos de envio e a garantia serão confirmados em seu orçamento por escrito.
Conversão de referência usando a taxa de câmbio salva com a data 15 de nov. de 2026. Os valores convertidos não constituem uma cotação.
Mais possibilidades para o seu espaço
Yield Lab Heat Mat Thermostat Temperature Controller
Perguntas e discussão
Tem alguma pergunta ou algo útil para compartilhar? Inicie a conversa.