Sizing a 12 inch Backdraft Damper Into a Big Run
- Duct diameter
- 12 in
- Type
- Round backdraft damper, duct insert
- Material
- Galvanized steel
- Mounting
- The whole assembly inserts into the duct
Apenas para fins de comparação. Solicite seu preço de atacado atual, disponibilidade e condições de entrega.
Nenhum pagamento é necessário. Uma conversa sobre o que você precisa.
Um pouco mais sobre este produto
Sizing a 12 inch Backdraft Damper Into a Big Run
Product details
- At twelve inches everything about a damper is bigger, including the consequences of getting it wrong.
- An open duct this size is a substantial hole in a building.
- With the fan off it moves cold air, odour and dust in the wrong direction continuously.
- On a room built around a pressure relationship, that undoes the whole design.
- The two blades here are correspondingly large plates, which is why the hinge arrangement matters.
- Each blade has its own hinge, so a blade that catches on debris does not hold its partner open with it.
- Galvanized steel keeps plates this size rigid enough to seat properly for years in a humid duct.
- A neoprene perimeter gasket takes the closure.
- On a plate this size that is the difference between a soft thud and a bang carrying through a building.
- Installing a Duct Insert of This Diameter
- The assembly pushes into the duct rather than mounting on a flange, which at this diameter saves genuine work.
- There is no transition piece to fabricate and nothing to line up beyond the duct itself.
- It installs in any orientation.
- Two things deserve attention at this size.
- Support the duct on both sides of the damper properly.
- A twelve inch run carries real weight, and a sagging duct distorts the housing until the blades no longer seat.
- The second is access to it afterwards.
- A damper buried in a ceiling void where nobody can reach it will eventually stop sealing and nobody will know.
- Atmosphere quote an opening requirement of four to eight hundredths of an inch of static pressure.
- A correctly specified twelve inch fan clears that easily at speed.
- Confirm it at low speed too.
- Check the swing and wipe the sealing face at every filter service.
- Why it matters: An open duct this size is a substantial hole in a building
- Blades: Two large plates, each on its own independent hinge
- Hinge design: A blade that catches cannot hold its partner open
- Body: Galvanized steel, stiff enough to keep large plates seating
- Seal: Neoprene perimeter gasket, which softens the closure
- Mounting: Inserts into the duct, with no transition piece to fabricate
Especificações
- Duct diameter
- 12 in
- Type
- Round backdraft damper, duct insert
- Material
- Galvanized steel
- Mounting
- The whole assembly inserts into the duct
- Opening pressure
- 0.04 to 0.08 in of static pressure
- Support
- Hold the duct both sides so the housing cannot distort
Vamos fazer isso funcionar para o seu projeto.
Inclua a quantidade desejada, o local de entrega, a região de cultivo e quaisquer requisitos de voltagem ou tipo de plugue em sua solicitação. As especificações, a disponibilidade, os termos de envio e a garantia serão confirmados em seu orçamento por escrito.
Conversão de referência usando a taxa de câmbio salva com a data 15 de nov. de 2026. Os valores convertidos não constituem uma cotação.
Mais possibilidades para o seu espaço
Yield Lab 6 Inch Purifier Activated Charcoal Filter
Yield Lab 6 inch 440 CFM Duct Inline Fan with 6" Carbon Filter Ducting and Clamps
Yield Lab 6 Inch 440 CFM Charcoal Filter and Duct Fan Combo Kit
Perguntas e discussão
Tem alguma pergunta ou algo útil para compartilhar? Inicie a conversa.