A brighter way to grow. Factory-direct wholesale. 15+ years of growing expertise
Controllers & MetersWholesale inquiry

TrolMaster Replacement Humidity Sensor for Beta-6

Model / SKU: SA-D1

When a Beta-6 Needs a Replacement Humidity Sensor

Beta-6 input
120 volts AC
Current part number
SA-H1 (supersedes SA-D1)
Beta-6 output
Relay
Beta-6 weight
0.56 kg
Source reference priceUSD 73.15

For comparison only. Request your current wholesale price, availability and delivery terms.

No payment required. A conversation about what you need.

Factory-direct support15+ years of experience
A CLOSER LOOK

A little more about this product

When a Beta-6 Needs a Replacement Humidity Sensor

Product details

  • A humidity controller is only as good as the probe hanging off it, and probes age faster than the box they plug into.
  • Grow room air is the hard case, because a sensor sitting in condensing humidity for years will read low and keep reading low.
  • The usual symptom is a dehumidifier that runs longer than it used to for the same room feel.
  • Swapping the probe is the low cost test to run before anyone suspects the controller.
  • The Beta-6 itself is a legacy unit in the TrolMaster range, so a spare probe keeps a working controller in service.
  • The controller uses a precision sensor in a 16 ft remote probe, switching connected equipment through an outlet.
  • This spare now carries the part number SA-H1 rather than SA-D1, which is worth knowing when cross referencing an older unit.
  • What the Beta-6 Does With It, Day and Night
  • The controller holds two humidity targets and a built in photocell decides which one applies.
  • Day and night set points run from 20 to 90 percent relative humidity, with a five point deadband between switching on and off.
  • That deadband is what stops a humidifier short cycling around a single number.
  • A photocell means the changeover follows room light rather than a clock, so it tracks a lighting schedule automatically.
  • It drives either a humidifier or a dehumidifier, not both at once.
  • The probe feeds all of that, which is why a drifted sensor shows up as a room that never settles.
  • Hang the probe at canopy height and clear of direct airflow from the unit it controls.
  • A probe in the dehumidifier's own discharge reads the machine rather than the room.
  • Keep the lead out of standing water even though the unit is rated for a normal room.
  • The controller weighs about 0.56 kg and measures 275 mm by 87 mm, for anyone planning a wall position.
  • What this is: The spare humidity probe alone, not a controller
  • For: The TrolMaster Beta-6 day and night humidity controller
  • Part code: SA-H1, superseding SA-D1
  • Probe lead: The Beta-6 probe is a 16 ft remote lead
  • Why replace: An aged probe reads low and overruns equipment
  • Controller set points: 20 to 90 percent, separate day and night values
  • Deadband: Five points, which prevents short cycling
  • Day or night sensing: A built in photocell, not a clock
  • Controller electrical: 120 volts in, relay output, 10 A fuse at 250 volts
  • Technical Specifications

Specifications

Current part number
SA-H1 (supersedes SA-D1)
Beta-6 input
120 volts AC
Beta-6 output
Relay
Beta-6 weight
0.56 kg

Let’s make it work for your project

Include your quantity, delivery destination, growing area and any voltage or plug requirements in your inquiry. Specifications, availability, shipping and warranty terms are confirmed in your written quotation.

LET’S GROW TOGETHER

Questions & discussion

0

Have a question or something useful to share? Start the conversation.

KEEP EXPLORING

More possibilities for your space

View all products
THE START OF SOMETHING GOOD

Let’s bring your project to light.

Tell us a little about what you need. We’ll use your details to prepare a relevant wholesale response.

Your product list

No payment. No obligation. Just a helpful conversation.