Controllers & MetersWholesale inquiry
Netafim Backflush Controller, 4 Outputs With DP Sensor, 12VDCL, With Mounting Bracket
Model / SKU: 00105-006260
Netafim 4 Output Backflush Controller on DC Power
- Power Source
- 4 x D alkaline (6V), 12V dry battery, or 12V rechargeable with 2 W solar panel
- Dimensions
- 9-1/2 in H x 5-5/8 in L x 3-1/4 in D
- Model
- 31NBCDCL4
- Outputs
- 4, 12VDC latching (2-wire)
Source reference priceUSD 998.77
For comparison only. Request your current wholesale price, availability and delivery terms.
No payment required. A conversation about what you need.
Factory-direct support15+ years of experience
A CLOSER LOOK
A little more about this product
Netafim 4 Output Backflush Controller on DC Power
Product details
- Four automatic filters on one header need a flush sequence that can run unattended for weeks.
- Netafim model 31NBCDCL4, item 00105-006260, gives that header 4 outputs for 12VDC latching solenoids.
- It runs on DC power, from four D-size alkaline batteries, a 12 volt battery, or a rechargeable battery charged by a small solar panel.
- Each output sits on a plug-in board of two, and the controller counts the boards it finds at configuration.
- Outputs are handed to the backflush valves first, starting at number 1.
- An alarm, a delay valve and a main valve, if chosen, take the next outputs in that order.
- On this four-output unit, adding a main valve leaves three outputs for filters.
- Any unused last station can be cancelled with the M key.
- Netafim lists the controller for automatic disc, sand media and screen filters.
- A mounting bracket is supplied, and the housing measures 9-1/2 x 5-5/8 x 3-1/4 in.
- How the DP Sensor Filter Controller Handles Faults
- The embedded electronic sensor reads inlet and outlet pressure through two command tubes.
- Put a 120 mesh filter, installer-supplied, on the high-pressure tube before the red port.
- When consecutive DP-triggered cycles pass the looping limit, the controller declares an endless loop.
- It shows the fault, energizes the alarm output and stops treating DP as a trigger.
- Flushing then continues on the interval countdown alone until the constant DP signal clears.
- On a blank screen with a silent keypad, check that every battery is installed correctly.
- The Main Card needs 6 volts on this DC model.
- Cycle totals for DP, timed and manual flushes can each be cleared with the plus or minus key.
- Four 12VDC latching outputs: Two plug-in boards of two outputs each.
- DC, battery or solar supply: D alkaline cells, a 12V battery or a solar-charged rechargeable.
- Flexible output allocation: Alarm, delay valve and main valve take the outputs after the filters.
- Looping protection: Switches to time-only flushing and raises the alarm after repeated DP cycles.
- Mounting bracket: Included with the controller.
- Technical Specifications
Specifications
- Model
- 31NBCDCL4
- Outputs
- 4, 12VDC latching (2-wire)
- Power Source
- 4 x D alkaline (6V), 12V dry battery, or 12V rechargeable with 2 W solar panel
- Optional Outputs
- Alarm, delay valve, main / pressure sustaining valve
- Operating Temperature
- 32-140°F (0-60°C)
- Dimensions
- 9-1/2 in H x 5-5/8 in L x 3-1/4 in D
- Weight
- 1.3 lb
- Flexible output allocation
- Alarm, delay valve and main valve take the outputs after the filters.
- Looping protection
- Switches to time-only flushing and raises the alarm after repeated DP cycles.
- Mounting bracket
- Included with the controller.
Let’s make it work for your project
Include your quantity, delivery destination, growing area and any voltage or plug requirements in your inquiry. Specifications, availability, shipping and warranty terms are confirmed in your written quotation.