Controllers & MetersWholesale inquiry
Growlink Batch TankLINK Temperature Sensor
Model / SKU: GL-LINK-TEMPSENSOR
Real-Time Nutrient Reads with the Growlink Batch TankLINK Temperature Sensor
- Power
- 24VDC via TankLINK controller
- Connection
- Screw terminal block (labeled on transmitter)
- Compatible Controller
- Growlink Batch TankLINK (pH, EC, Temp, Level inputs)
- Calibration
- LCD wizard, paired with pH & EC probes
Source reference priceUSD 44.99
For comparison only. Request your current wholesale price, availability and delivery terms.
No payment required. A conversation about what you need.
Factory-direct support15+ years of experience
A CLOSER LOOK
A little more about this product
Real-Time Nutrient Reads with the Growlink Batch TankLINK Temperature Sensor
Product details
- The Growlink Batch TankLINK Temperature Sensor reads nutrient solution temperature directly inside a batch tank or reservoir.
- The probe ties into the Batch TankLINK controller's screw terminal block.
- It reports continuously at 0.02°F resolution with ±3.6°F (±2°C) accuracy.
- The controller itself operates from 50 to 122°F.
- That range covers the 68–72°F target band most hydroponic crops respond to inside the root zone.
- Drop the probe into calibration solution alongside the pH and EC probes during the LCD wizard.
- It locks in for the run.
- Wiring the TankLINK Temperature Probe into a Live Recirculation Loop
- The sensor handles the temperature input on a controller that already measures pH, EC, and tank level on the same board.
- Pair it with a chiller or in-line heater triggered by the TankLINK.
- The nutrient solution temperature probe data then holds tighter to setpoint through lights-on heat spikes.
- On drain-to-waste schedules, the temperature read alongside EC tells you whether morning-shot solubility issues are temperature-driven.
- That separates a chiller problem from a recipe problem before you adjust the feed.
- Plug-and-play wiring keeps a single-probe swap during teardown to a few minutes.
- No driver shuffling — just the batch tank temperature probe back into the terminal block and a quick recalibrate.
- Most rooms keep one spare on hand for summer runs when reservoir temps climb hardest, particularly in greenhouses without dedicated cooling.
- ±3.6°F (±2°C) Accuracy: Tight enough to confirm the nutrient line stays inside the 68–72°F sweet spot.
- 0.02°F Resolution: Picks up small drifts during lights-on spikes before they widen into a real swing.
- Direct TankLINK Integration: Wires straight into the Batch TankLINK controller's labeled screw terminal block.
- Calibration Wizard Compatible: Drops into the LCD wizard alongside pH and EC for a single calibration pass.
- Plug-and-Play Replacement: Probe swap during teardown takes minutes — terminal block in, recalibrate, run.
- Technical Specifications
Specifications
- Connection
- Screw terminal block (labeled on transmitter)
- Compatible Controller
- Growlink Batch TankLINK (pH, EC, Temp, Level inputs)
- Calibration
- LCD wizard, paired with pH & EC probes
- Power
- 24VDC via TankLINK controller
- Direct TankLINK Integration
- Wires straight into the Batch TankLINK controller's labeled screw terminal block.
- Calibration Wizard Compatible
- Drops into the LCD wizard alongside pH and EC for a single calibration pass.
Let’s make it work for your project
Include your quantity, delivery destination, growing area and any voltage or plug requirements in your inquiry. Specifications, availability, shipping and warranty terms are confirmed in your written quotation.
KEEP EXPLORING
View all productsMore possibilities for your space
Controllers & Meters
Yield Lab 8 Outlet 120v/240v Grow Light Relay Controller
Source referenceUSD 89.95
Questions & discussion
Have a question or something useful to share? Start the conversation.