Reading Acidity with the Growlink Batch TankLINK pH Sensor
- pH Range
- 0–14
- Connector
- BNC (push + 1/4-turn CW lock)
- Cable Length
- 10 ft (3 m)
- Calibration
- Two-point @ pH 7.00 and pH 4.01 via LCD wizard
Source reference priceUSD 79.99
For comparison only. Request your current wholesale price, availability and delivery terms.
No payment required. A conversation about what you need.
Factory-direct support15+ years of experience
A CLOSER LOOK
A little more about this product
Reading Acidity with the Growlink Batch TankLINK pH Sensor
Product details
- The Growlink Batch TankLINK pH Sensor reads nutrient solution acidity inside a batch tank or reservoir in real time.
- The probe covers the full 0–14 pH range at ±0.02 pH accuracy with 0.01 pH resolution.
- A 10-foot cable runs from the sensor to the Batch TankLINK controller.
- The cable terminates on a BNC connector that pushes onto the controller port.
- A quarter-turn clockwise locks it in place.
- Inside the typical hydroponic feed window of 5.5–6.5 pH, that accuracy is tight enough to confirm a fresh batch lands inside spec on the first mix.
- Calibrating and Maintaining the TankLINK pH Probe
- Calibration is a two-point process with pH 7.00 and pH 4.01 buffer solutions.
- The TankLINK LCD wizard walks the probe through each buffer in turn and locks the cal at a stable voltage.
- Run cal at the start of each batch or whenever the reading drifts past ±0.05 pH between known mixes.
- The pH probe ships in a storage cap of pH 4 buffer and potassium chloride.
- The membrane needs to stay wet between runs.
- A dry membrane is the fastest way to kill a pH probe early.
- Keep the storage cap on whenever the sensor sits out of solution.
- Plug-and-play wiring keeps a single-probe swap during teardown under a minute.
- The nutrient tank pH probe twists out of the BNC port and a fresh one twists in.
- 0–14 pH Range: Full-scale read covers anything a hydro feed will ever hit, including post-dosing spikes.
- ±0.02 pH Accuracy: Tight enough to confirm fresh mixes land in the 5.5–6.5 feed window on the first measurement.
- 0.01 pH Resolution: Catches small drifts between feeds before they show up as canopy stress symptoms.
- BNC Connector with 1/4-Turn Lock: Push-on, twist-lock fit on the TankLINK controller's labeled port — no rewiring at swap.
- Two-Point Calibration: pH 7.00 and pH 4.01 buffers through the LCD wizard handle the full cal in one pass.
- Technical Specifications
Specifications
- pH Range
- 0–14
- Connector
- BNC (push + 1/4-turn CW lock)
- Cable Length
- 10 ft (3 m)
- Calibration
- Two-point @ pH 7.00 and pH 4.01 via LCD wizard
- Compatible Controller
- Growlink Batch TankLINK
- Two-Point Calibration
- pH 7.00 and pH 4.01 buffers through the LCD wizard handle the full cal in one pass.
Let’s make it work for your project
Include your quantity, delivery destination, growing area and any voltage or plug requirements in your inquiry. Specifications, availability, shipping and warranty terms are confirmed in your written quotation.
KEEP EXPLORING
View all productsMore possibilities for your space
Controllers & Meters
Yield Lab 8 Outlet 120v/240v Grow Light Relay Controller
Source referenceUSD 89.95
Questions & discussion
Have a question or something useful to share? Start the conversation.