A brighter way to grow. Factory-direct wholesale. 15+ years of growing expertise
Controllers & MetersWholesale inquiry

Autopilot CO2 Controller APC8200 · 15 ft Remote NDIR Sensor

Model / SKU: APC8200

What the Autopilot CO2 Controller Reads and Switches

Unit dimensions
9.7 x 7.5 x 3.9 in
Sensor cable length
15 ft
Source reference priceUSD 298.65

For comparison only. Request your current wholesale price, availability and delivery terms.

No payment required. A conversation about what you need.

Factory-direct support15+ years of experience
A CLOSER LOOK

A little more about this product

What the Autopilot CO2 Controller Reads and Switches

Product details

  • The sensing element is a two-channel low-drift NDIR type, carried in a remote probe that also holds a photocell.
  • That probe rides on a 15 ft data cable, so it can hang in the canopy while the box stays on a wall.
  • Range on the CO2 function runs from 0 to 5000 ppm.
  • That covers ambient outdoor air at one end and a heavily enriched sealed room at the other.
  • Both the setpoint and the ppm deadband are adjustable.
  • The deadband is what stops a generator short-cycling around the target, and it is the first setting worth thinking about.
  • Readings land on a trend chart that records per minute, per hour, per day and per week.
  • Memory holds up to seven days, and an adjustable zoom steps through those intervals.
  • Green LED lights report the unit status at a glance.
  • The unit measures 9.7 x 7.5 x 3.9 in and ships at 2.3 lb.
  • Part number is APC8200, with UPC 638104020701 and GTIN-14 10638104020708.
  • Setting Up a CO2 Controller for Grow Room Enrichment
  • A co2 controller for grow room work only pays off once the room is genuinely sealed.
  • Enrichment bleeds out of a leaky tent faster than any source can replace it, so weatherstripping comes before programming.
  • Set the target for lights-on only, because plants stop fixing carbon in the dark and the gas just accumulates.
  • The photocell in the probe handles that switch without a separate timer on the circuit.
  • A wide deadband means fewer source starts and a slower swing, while a narrow one holds tighter and cycles more often.
  • Most sealed rooms settle somewhere in between once the chart shows how fast they bleed down.
  • That chart is the real diagnostic tool on this unit.
  • A sawtooth that falls away quickly between fills points at a leak, or at an exhaust fan still running on its own timer.
  • A flat line that never reaches target points at an undersized source or an empty tank.
  • The fault codes are worth knowing before anything goes wrong.
  • Err4 flags the infrared lamp and Err6 flags the sensor connection.
  • Err7 is a temperature or humidity fault, while Err5 and Err8 are internal to the unit.
  • Mount it where the display can be read and the outlet is easy to reach.
  • Keep the probe clear of a burner discharge and out of the direct path of an intake fan.
  • Two-channel NDIR sensor: A low-drift infrared reading rather than a chemical cell.
  • 0 to 5000 ppm range: Covers ambient air through a heavily enriched sealed room.

Specifications

Sensor cable length
15 ft
Unit dimensions
9.7 x 7.5 x 3.9 in

Let’s make it work for your project

Include your quantity, delivery destination, growing area and any voltage or plug requirements in your inquiry. Specifications, availability, shipping and warranty terms are confirmed in your written quotation.

LET’S GROW TOGETHER

Questions & discussion

0

Have a question or something useful to share? Start the conversation.