Ventilation & ClimateWholesale inquiry
12 inch Backdraft Damper
Model / SKU: VTBDD12
Sizing a 12 inch Backdraft Damper Into a Big Run
- Duct diameter
- 12 in
- Type
- Round backdraft damper, duct insert
- Material
- Galvanized steel
- Mounting
- The whole assembly inserts into the duct
Source reference priceUSD 51.68
For comparison only. Request your current wholesale price, availability and delivery terms.
No payment required. A conversation about what you need.
Factory-direct support15+ years of experience
A CLOSER LOOK
A little more about this product
Sizing a 12 inch Backdraft Damper Into a Big Run
Product details
- At twelve inches everything about a damper is bigger, including the consequences of getting it wrong.
- An open duct this size is a substantial hole in a building.
- With the fan off it moves cold air, odour and dust in the wrong direction continuously.
- On a room built around a pressure relationship, that undoes the whole design.
- The two blades here are correspondingly large plates, which is why the hinge arrangement matters.
- Each blade has its own hinge, so a blade that catches on debris does not hold its partner open with it.
- Galvanized steel keeps plates this size rigid enough to seat properly for years in a humid duct.
- A neoprene perimeter gasket takes the closure.
- On a plate this size that is the difference between a soft thud and a bang carrying through a building.
- Installing a Duct Insert of This Diameter
- The assembly pushes into the duct rather than mounting on a flange, which at this diameter saves genuine work.
- There is no transition piece to fabricate and nothing to line up beyond the duct itself.
- It installs in any orientation.
- Two things deserve attention at this size.
- Support the duct on both sides of the damper properly.
- A twelve inch run carries real weight, and a sagging duct distorts the housing until the blades no longer seat.
- The second is access to it afterwards.
- A damper buried in a ceiling void where nobody can reach it will eventually stop sealing and nobody will know.
- Atmosphere quote an opening requirement of four to eight hundredths of an inch of static pressure.
- A correctly specified twelve inch fan clears that easily at speed.
- Confirm it at low speed too.
- Check the swing and wipe the sealing face at every filter service.
- Why it matters: An open duct this size is a substantial hole in a building
- Blades: Two large plates, each on its own independent hinge
- Hinge design: A blade that catches cannot hold its partner open
- Body: Galvanized steel, stiff enough to keep large plates seating
- Seal: Neoprene perimeter gasket, which softens the closure
- Mounting: Inserts into the duct, with no transition piece to fabricate
Specifications
- Duct diameter
- 12 in
- Type
- Round backdraft damper, duct insert
- Material
- Galvanized steel
- Mounting
- The whole assembly inserts into the duct
- Opening pressure
- 0.04 to 0.08 in of static pressure
- Support
- Hold the duct both sides so the housing cannot distort
Let’s make it work for your project
Include your quantity, delivery destination, growing area and any voltage or plug requirements in your inquiry. Specifications, availability, shipping and warranty terms are confirmed in your written quotation.
KEEP EXPLORING
View all productsMore possibilities for your space
Ventilation & Climate
Yield Lab 6 Inch Purifier Activated Charcoal Filter
Source referenceUSD 149.95
Ventilation & Climate
Yield Lab 6 inch 440 CFM Duct Inline Fan with 6" Carbon Filter Ducting and Clamps
Source referenceUSD 139.95
Ventilation & Climate
Yield Lab 6 Inch 440 CFM Charcoal Filter and Duct Fan Combo Kit
Source referenceUSD 119.95
Questions & discussion
Have a question or something useful to share? Start the conversation.