BLIŻSZE SPOJRZENIE
Trochę więcej o tym produkcie
Reading pH with the Growlink Sensorex pH Sensor
Product details
- The Growlink Sensorex pH Sensor reads 0–14 pH on a 12 mm Ultem-body electrode designed for samples where contamination would foul a single-junction probe.
- The double junction reference design isolates the Ag/AgCl reference cell behind a second junction filled with KCl.
- Heavy metals and organic compounds have to migrate through both junctions before they reach the reference wire.
- That extra barrier extends working life in nutrient solutions and recirculating fertigation lines where dissolved salts climb fast.
- Operating range is 0–80°C with sealed gel reference electrolyte.
- No top-up, no fill cap, low maintenance through the run.
- Cable, BNC, and Calibration for the Double Junction pH Probe
- Terminations are BNC at the meter end and Ultem at the wet end.
- The BNC connector plugs into any meter that accepts the standard fit, including the Growlink Batch TankLINK controller.
- Two cable lengths cover most reservoir layouts.
- The 10 ft cable handles bench-mounted controllers within reach of the tank.
- The 30 ft cable handles wall-mounted setups across the room.
- Both variants use the same Sensorex S200CD pH sensor head.
- The only spec difference is the cable run from probe to controller.
- The pH bulb sits recessed inside the polymer body so the glass doesn't crack against the bottom of a beaker or calibration cup.
- This double junction pH probe also resists silver-ion reference poisoning common in long-running recirculation systems.
- Run two-point calibration with pH 7 and pH 4 buffers at the start of each batch.
- Double Junction Reference: Second KCl-filled junction keeps heavy metals and sample contaminants away from the Ag/AgCl reference cell.
- Ultem® Polymer Body: Holds up to fertigation chemistry and field handling — won't crack like glass-body electrodes.
- Sealed Gel Reference: No top-up, no fill cap, no electrolyte maintenance across the run — pull, calibrate, replace.
- 0–14 pH Range, 0–80°C: Full pH scale across the operating temperature window that covers any indoor or greenhouse reservoir.
- BNC + Recessed pH Bulb: Standard BNC fit on TankLINK or any BNC meter; recessed glass tip resists impact damage at the beaker bottom.
- Technical Specifications
Specyfikacje
- pH Range
- 0–14 pH
- Operating Temperature
- 0–80 °C (32–176 °F)
- Body Material
- Ultem® polymer
- Diameter / Length
- 12 mm × 150 mm
- Connector
- BNC (booted BNC on the 30 ft variant)
- Cable Length Options
- 10 ft (3 m) or 30 ft (9 m)
- Calibration
- Two-point with pH 7.00 and pH 4.01 buffers
- Compatible Controllers
- Growlink Batch TankLINK and any BNC pH meter
- Sealed Gel Reference
- No top-up, no fill cap, no electrolyte maintenance across the run — pull, calibrate, replace.
- SIZE
- 10' Cable, 30' Cable
Pytania i dyskusja
Masz pytanie lub chcesz się czymś podzielić? Rozpocznij rozmowę.