Deze inhoud is momenteel beschikbaar in de oorspronkelijke taal.
Ventilatie en klimaatGroothandelsaanvraag
8 inch Backdraft Damper
Model / SKU: VTBDD8
Where an 8 inch Backdraft Damper Earns Its Place
- Duct size
- Eight inches, which covers most single room extraction runs
- Duct diameter
- 8 in
- Type
- Round backdraft damper, duct insert
- Material
- Galvanized steel
ReferentieprijsEUR 23.69
Ter vergelijking. Vraag naar de actuele groothandelsprijs, beschikbaarheid en leveringsvoorwaarden.
Geen betaling vereist. Een gesprek over uw behoeften.
Fabrieksdirecte ondersteuningMeer dan 15 jaar ervaring
EEN NADERE KIJK
Nog wat meer informatie over dit product.
Where an 8 inch Backdraft Damper Earns Its Place
Product details
- Eight inches is where a lot of single room extraction ends up.
- It is also the size where backflow starts costing money rather than merely being a nuisance.
- A duct this diameter moves a serious volume in either direction.
- With the fan off, an eight inch open run will let cold air, smell and roof dust travel back into a room all night.
- Sealed rooms lose their pressure relationship the same way.
- This damper stops that with two galvanized blades hung on independent hinges.
- Independence is the part to look for in any damper, because a shared shaft turns one stuck blade into two.
- The whole assembly inserts into the duct, so there is no flange, no adaptor and no transition piece.
- It installs in any orientation, which matters on a vertical riser as much as on a horizontal run.
- The Neoprene Gasket and What a Bad Seal Costs
- The blades close onto a neoprene perimeter gasket rather than onto bare steel.
- That choice does two jobs at once.
- It takes the clang out of a closure, which is a real consideration in a building where people sleep or work nearby.
- It also fills the gap that a metal edge always leaves.
- On a duct this size a thin gap around the circumference adds up to a meaningful leak.
- Keep the gasket in mind through the life of the installation.
- Dust builds on the sealing face, resin from a room carries into the duct, and a face that cannot seat cleanly leaks quietly for months.
- Wipe it when the filter is serviced.
- Atmosphere quote an opening requirement of four to eight hundredths of an inch of static pressure.
- Any reasonably specified eight inch fan exceeds that at full speed.
- Check it at the lowest speed the fan will actually be run, not at full.
- Duct size: Eight inches, which covers most single room extraction runs
- Function: Prevents backflow of cold air, odour and dust when the fan stops
- Blades: Two galvanized blades, each on an independent hinge
- Seal: Neoprene perimeter gasket, not a bare metal edge
- Noise: The gasket takes the clang out of every closure
- Leakage: A gasketed face closes the gap a metal edge always leaves
- Mounting: The assembly inserts into the duct with no flange needed
Specificaties
- Duct diameter
- 8 in
- Type
- Round backdraft damper, duct insert
- Material
- Galvanized steel
- Mounting
- The whole assembly inserts into the duct
- Opening pressure
- 0.04 to 0.08 in of static pressure
- Duct size
- Eight inches, which covers most single room extraction runs
- Noise
- The gasket takes the clang out of every closure
Laten we ervoor zorgen dat het lukt voor jouw project.
Vermeld in uw aanvraag de gewenste hoeveelheid, de bezorgbestemming, het teeltgebied en eventuele spannings- of stekkervereisten. Specificaties, beschikbaarheid, verzending en garantievoorwaarden worden bevestigd in uw schriftelijke offerte.
Referentieconversie met behulp van de opgeslagen wisselkoers van datum 15 nov. 2026. De omgerekende bedragen zijn geen offerte.
BLIJF ONTDEKKEN
Bekijk alle productenMeer mogelijkheden voor uw ruimte
Ventilatie en klimaat
Yield Lab 6 inch 440 CFM Duct Inline Fan with 6" Carbon Filter Ducting and Clamps
BronvermeldingEUR 126.79
Ventilatie en klimaat
Yield Lab 6 Inch 440 CFM Charcoal Filter and Duct Fan Combo Kit
BronvermeldingEUR 108.67
Vragen en discussie
Heb je een vraag of iets nuttigs te delen? Start het gesprek.