더 밝은 성장 방식. 공장 직송 도매. 15년 이상 축적된 전문성

이 콘텐츠는 현재 원어로 제공됩니다.

TrolMaster Replacement Temp Sensor for Beta-2 and Beta-4

모델/SKU: SA-NTC

What the TrolMaster SA-NTC Is and How It Reads

Type
Replacement temperature sensor
Compatible controllers
Beta-2 and Beta-4
Light
Keep it shaded, since radiant heat makes a probe read high
Fan controller trap
Never hang it in the airstream of the fan it is controlling
출처 참조 가격KRW 41,979

비교 목적으로만 사용하십시오. 현재 도매 가격, 재고 여부 및 배송 조건을 문의하십시오.

결제는 필요하지 않습니다. 필요한 사항에 대해 이야기 나눠보세요.

공장 직송 지원15년 이상의 경력
자세히 살펴보기

이 제품에 대해 좀 더 자세히 알아보겠습니다.

What the TrolMaster SA-NTC Is and How It Reads

Product details

  • The letters describe the technology.
  • NTC stands for negative temperature coefficient, which means the resistance of the element drops as the temperature climbs.
  • There is no electronics in the probe at all.
  • The controller applies a small voltage, measures what comes back, and converts that resistance into a figure on the display.
  • That simplicity is why these probes last, and it is also why their failures look the way they do.
  • A cut or crushed lead reads as an open circuit.
  • A controller seeing an open circuit displays an extreme value or an error rather than a plausible wrong number.
  • A partly damaged cable is harder, because it can read plausibly and still be wrong by several degrees.
  • If a room is holding a temperature that does not match a separate thermometer, suspect the probe before suspecting the controller.
  • This part fits the Beta-2 and the Beta-4, both of which ship with one in the box.
  • Probe Placement, and the Feedback Trap on a Fan Controller
  • Where the probe hangs decides what the controller actually controls.
  • Put it at canopy height, since that is the air the crop is living in rather than the warmer layer at ceiling level.
  • Keep it out of direct lamp light.
  • A sensor absorbing radiant heat reads higher than the air around it, and the room then runs colder than intended.
  • Shade it or tuck it behind something opaque.
  • Now the trap specific to a fan controller.
  • Never hang the probe in the airstream of the fan the controller is driving.
  • Doing that creates a loop.
  • The fan blows cool air across its own sensor, the sensor reports that the room is fine, and the fan slows down.
  • The reading then climbs again and the fan surges.
  • The result is a fan that hunts constantly and a room that never settles.
  • Place it away from the fan and away from any duct discharge.
  • Secure the lead so it cannot be pulled, since a tug at the connector is how most of these fail.
  • Function: Replacement temperature probe for the Beta-2 and the Beta-4
  • Technology: A negative temperature coefficient thermistor
  • How it works: Resistance falls as temperature rises and the controller converts it
  • No electronics: Nothing active inside the probe, which is why they last

명세서

Type
Replacement temperature sensor
Compatible controllers
Beta-2 and Beta-4
Light
Keep it shaded, since radiant heat makes a probe read high
Fan controller trap
Never hang it in the airstream of the fan it is controlling

프로젝트에 도움이 되도록 만들어 봅시다.

문의 시 수량, 배송지, 재배 ​​지역, 전압 또는 플러그 요구 사항을 포함해 주십시오. 사양, 재고 여부, 배송 및 보증 조건은 서면 견적서에서 확인하실 수 있습니다.

저장된 환율을 사용한 참조 변환 (날짜 기준) 2026. 11. 15.. 환산된 금액은 견적이 아닙니다.

함께 성장해요

질문 및 토론

0

궁금한 점이 있거나 유용한 정보를 공유하고 싶으신가요? 대화를 시작해 보세요.

계속 탐험하세요

당신의 공간을 위한 더 많은 가능성

모든 제품 보기
좋은 일의 시작

당신의 프로젝트를 세상에 선보여 봅시다.

필요한 사항에 대해 간략하게 알려주세요. 고객님의 정보를 바탕으로 적절한 도매 견적을 준비해 드리겠습니다.

제품 목록

비용 부담이나 의무는 없습니다. 유익한 대화만 나누겠습니다.