더 밝은 성장 방식. 공장 직송 도매. 15년 이상 축적된 전문성

이 콘텐츠는 현재 원어로 제공됩니다.

TrolMaster Replacement Humidity Sensor for Beta-6

모델/SKU: SA-D1

When a Beta-6 Needs a Replacement Humidity Sensor

Beta-6 input
120 volts AC
Current part number
SA-H1 (supersedes SA-D1)
Beta-6 output
Relay
Beta-6 weight
0.56 kg
출처 참조 가격KRW 97,732

비교 목적으로만 사용하십시오. 현재 도매 가격, 재고 여부 및 배송 조건을 문의하십시오.

결제는 필요하지 않습니다. 필요한 사항에 대해 이야기 나눠보세요.

공장 직송 지원15년 이상의 경력
자세히 살펴보기

이 제품에 대해 좀 더 자세히 알아보겠습니다.

When a Beta-6 Needs a Replacement Humidity Sensor

Product details

  • A humidity controller is only as good as the probe hanging off it, and probes age faster than the box they plug into.
  • Grow room air is the hard case, because a sensor sitting in condensing humidity for years will read low and keep reading low.
  • The usual symptom is a dehumidifier that runs longer than it used to for the same room feel.
  • Swapping the probe is the low cost test to run before anyone suspects the controller.
  • The Beta-6 itself is a legacy unit in the TrolMaster range, so a spare probe keeps a working controller in service.
  • The controller uses a precision sensor in a 16 ft remote probe, switching connected equipment through an outlet.
  • This spare now carries the part number SA-H1 rather than SA-D1, which is worth knowing when cross referencing an older unit.
  • What the Beta-6 Does With It, Day and Night
  • The controller holds two humidity targets and a built in photocell decides which one applies.
  • Day and night set points run from 20 to 90 percent relative humidity, with a five point deadband between switching on and off.
  • That deadband is what stops a humidifier short cycling around a single number.
  • A photocell means the changeover follows room light rather than a clock, so it tracks a lighting schedule automatically.
  • It drives either a humidifier or a dehumidifier, not both at once.
  • The probe feeds all of that, which is why a drifted sensor shows up as a room that never settles.
  • Hang the probe at canopy height and clear of direct airflow from the unit it controls.
  • A probe in the dehumidifier's own discharge reads the machine rather than the room.
  • Keep the lead out of standing water even though the unit is rated for a normal room.
  • The controller weighs about 0.56 kg and measures 275 mm by 87 mm, for anyone planning a wall position.
  • What this is: The spare humidity probe alone, not a controller
  • For: The TrolMaster Beta-6 day and night humidity controller
  • Part code: SA-H1, superseding SA-D1
  • Probe lead: The Beta-6 probe is a 16 ft remote lead
  • Why replace: An aged probe reads low and overruns equipment
  • Controller set points: 20 to 90 percent, separate day and night values
  • Deadband: Five points, which prevents short cycling
  • Day or night sensing: A built in photocell, not a clock
  • Controller electrical: 120 volts in, relay output, 10 A fuse at 250 volts
  • Technical Specifications

명세서

Current part number
SA-H1 (supersedes SA-D1)
Beta-6 input
120 volts AC
Beta-6 output
Relay
Beta-6 weight
0.56 kg

프로젝트에 도움이 되도록 만들어 봅시다.

문의 시 수량, 배송지, 재배 ​​지역, 전압 또는 플러그 요구 사항을 포함해 주십시오. 사양, 재고 여부, 배송 및 보증 조건은 서면 견적서에서 확인하실 수 있습니다.