When a Beta-6 Needs a Replacement Humidity Sensor
- Beta-6 input
- 120 volts AC
- Current part number
- SA-H1 (supersedes SA-D1)
- Beta-6 output
- Relay
- Beta-6 weight
- 0.56 kg
출처 참조 가격KRW 97,732
비교 목적으로만 사용하십시오. 현재 도매 가격, 재고 여부 및 배송 조건을 문의하십시오.
결제는 필요하지 않습니다. 필요한 사항에 대해 이야기 나눠보세요.
공장 직송 지원15년 이상의 경력
자세히 살펴보기
이 제품에 대해 좀 더 자세히 알아보겠습니다.
When a Beta-6 Needs a Replacement Humidity Sensor
Product details
- A humidity controller is only as good as the probe hanging off it, and probes age faster than the box they plug into.
- Grow room air is the hard case, because a sensor sitting in condensing humidity for years will read low and keep reading low.
- The usual symptom is a dehumidifier that runs longer than it used to for the same room feel.
- Swapping the probe is the low cost test to run before anyone suspects the controller.
- The Beta-6 itself is a legacy unit in the TrolMaster range, so a spare probe keeps a working controller in service.
- The controller uses a precision sensor in a 16 ft remote probe, switching connected equipment through an outlet.
- This spare now carries the part number SA-H1 rather than SA-D1, which is worth knowing when cross referencing an older unit.
- What the Beta-6 Does With It, Day and Night
- The controller holds two humidity targets and a built in photocell decides which one applies.
- Day and night set points run from 20 to 90 percent relative humidity, with a five point deadband between switching on and off.
- That deadband is what stops a humidifier short cycling around a single number.
- A photocell means the changeover follows room light rather than a clock, so it tracks a lighting schedule automatically.
- It drives either a humidifier or a dehumidifier, not both at once.
- The probe feeds all of that, which is why a drifted sensor shows up as a room that never settles.
- Hang the probe at canopy height and clear of direct airflow from the unit it controls.
- A probe in the dehumidifier's own discharge reads the machine rather than the room.
- Keep the lead out of standing water even though the unit is rated for a normal room.
- The controller weighs about 0.56 kg and measures 275 mm by 87 mm, for anyone planning a wall position.
- What this is: The spare humidity probe alone, not a controller
- For: The TrolMaster Beta-6 day and night humidity controller
- Part code: SA-H1, superseding SA-D1
- Probe lead: The Beta-6 probe is a 16 ft remote lead
- Why replace: An aged probe reads low and overruns equipment
- Controller set points: 20 to 90 percent, separate day and night values
- Deadband: Five points, which prevents short cycling
- Day or night sensing: A built in photocell, not a clock
- Controller electrical: 120 volts in, relay output, 10 A fuse at 250 volts
- Technical Specifications
명세서
- Current part number
- SA-H1 (supersedes SA-D1)
- Beta-6 input
- 120 volts AC
- Beta-6 output
- Relay
- Beta-6 weight
- 0.56 kg