더 밝은 성장 방식. 공장 직송 도매. 15년 이상 축적된 전문성

이 콘텐츠는 현재 원어로 제공됩니다.

TrolMaster Replacement CO2 Sensor for Beta-8

모델/SKU: SA-S8

What the TrolMaster SA-S8 Replaces in a BETA-8

Type
Replacement CO2 sensor head
Compatible controller
BETA-8 Digital CO2 PPM Controller
출처 참조 가격KRW 256,082

비교 목적으로만 사용하십시오. 현재 도매 가격, 재고 여부 및 배송 조건을 문의하십시오.

결제는 필요하지 않습니다. 필요한 사항에 대해 이야기 나눠보세요.

공장 직송 지원15년 이상의 경력
자세히 살펴보기

이 제품에 대해 좀 더 자세히 알아보겠습니다.

What the TrolMaster SA-S8 Replaces in a BETA-8

Product details

  • On a BETA-8 the controller is a box on a wall and the sensor is a head on a lead hanging near the canopy.
  • Everything that actually measures sits in that head.
  • The sensing element is NDIR, accurate to plus or minus fifty parts per million.
  • It sits on a sixteen foot cable, with a photocell built into the same head.
  • That photocell is what stops carbon dioxide injection during the dark period.
  • So this part carries two functions rather than one, and losing it costs both the reading and the night behaviour.
  • The head is the component that lives in the room rather than on the wall, which is why it is the part that wears.
  • It sits in warm humid air, it collects dust, and it is the thing that gets knocked when a canopy is moved.
  • Making it a service part is the right design, and it means a controller with a drifting reading does not become scrap.
  • When an NDIR Head Needs Replacing Rather Than Cleaning
  • Infrared measurement drifts slowly over years rather than failing outright, and that is what makes a bad sensor hard to spot.
  • Watch for three particular patterns.
  • A reading that never moves regardless of injection or ventilation is the clearest, because room levels always move.
  • A figure that sits implausibly low while a regulator runs continuously points the same way.
  • So does one that sits high while a room is being flushed.
  • Cross-check with a separate meter before spending anything, since a controller arguing with itself costs less to diagnose than to replace.
  • Dust on the head is worth clearing first, gently and dry.
  • Where the photocell is the failing half, the symptom is different again and easy to misread as a control fault.
  • Injection that never begins under lamps, or never stops in darkness, points at the light sensing side rather than the gas side.
  • Function: The replacement remote sensor head for a BETA-8 controller
  • Two jobs: It carries both the gas measurement and the photocell
  • Accuracy: An NDIR element, accurate to plus or minus fifty parts per million
  • Cable: A sixteen foot lead
  • Why it wears: The head lives in warm humid air and collects dust
  • Drift symptom: A reading that never moves whatever the room is doing
  • Photocell symptom: Injection that never starts under lamps or never stops at night
  • Before replacing: Cross-check against a separate meter and clear dust gently
  • Service part: A drifting sensor does not force a whole controller replacement

명세서

Type
Replacement CO2 sensor head
Compatible controller
BETA-8 Digital CO2 PPM Controller

프로젝트에 도움이 되도록 만들어 봅시다.

문의 시 수량, 배송지, 재배 ​​지역, 전압 또는 플러그 요구 사항을 포함해 주십시오. 사양, 재고 여부, 배송 및 보증 조건은 서면 견적서에서 확인하실 수 있습니다.

저장된 환율을 사용한 참조 변환 (날짜 기준) 2026. 11. 15.. 환산된 금액은 견적이 아닙니다.

함께 성장해요

질문 및 토론

0

궁금한 점이 있거나 유용한 정보를 공유하고 싶으신가요? 대화를 시작해 보세요.

계속 탐험하세요

당신의 공간을 위한 더 많은 가능성

모든 제품 보기
좋은 일의 시작

당신의 프로젝트를 세상에 선보여 봅시다.

필요한 사항에 대해 간략하게 알려주세요. 고객님의 정보를 바탕으로 적절한 도매 견적을 준비해 드리겠습니다.

제품 목록

비용 부담이나 의무는 없습니다. 유익한 대화만 나누겠습니다.