더 밝은 성장 방식. 공장 직송 도매. 15년 이상 축적된 전문성

이 콘텐츠는 현재 원어로 제공됩니다.

Titan Controls CO2 Regulator

모델/SKU: 702710

Titan Controls CO2 Regulator for Tank-Fed Grow Rooms

Flow Range
0.5-15 SCFH
Compatible Controls
Any 120 volt CO2 controller or timer
Tank Pressure Gauge
Shows how much CO2 is left in the cylinder.
Controller Compatible
Atlas CO2 controllers, Apollo timers and wall timers.
출처 참조 가격KRW 138,816

비교 목적으로만 사용하십시오. 현재 도매 가격, 재고 여부 및 배송 조건을 문의하십시오.

결제는 필요하지 않습니다. 필요한 사항에 대해 이야기 나눠보세요.

공장 직송 지원15년 이상의 경력
자세히 살펴보기

이 제품에 대해 좀 더 자세히 알아보겠습니다.

Titan Controls CO2 Regulator for Tank-Fed Grow Rooms

Product details

  • Enriching a sealed room with bottled CO2 starts at the tank, and this regulator is the piece that meters the gas out.
  • Titan Controls item 702710 combines a tank pressure gauge, a flowmeter and a heavy-duty 120 volt solenoid in one body.
  • The flowmeter reads from 0.5 to 15 standard cubic feet per hour, set with a brass flow adjustment knob.
  • A ball rises and falls inside the clear tube, so the flow rate is visible at a glance.
  • The solenoid opens only when it receives power, which lets a controller or timer decide when CO2 flows.
  • That makes it compatible with any 120 volt CO2 controller or timer, including Titan's Atlas monitor/controllers and Apollo repeat cycle timers.
  • With an Atlas controller, gas runs whenever the room drops below the PPM set point.
  • With a timer, the regulator opens at set intervals based on room volume and flow rate.
  • Titan's instructions include a timing chart for raising a room by about 1,100 to 1,200 PPM, to roughly 1,500 PPM total.
  • For rooms over 2,000 cubic feet, the sheet gives a simple formula for working out run time.
  • Installing a CO2 Regulator With Solenoid on the Tank
  • Before connecting, crack the tank valve open for about 3 seconds to blow out any debris, then close it.
  • Seat one of the white plastic washers inside the large brass nut to prevent leaks.
  • Tighten the nut with a crescent wrench, not pliers, and do not hold the plastic flowmeter while tightening.
  • Skip pipe thread tape and lubricants on the tank connection.
  • Run the 1/4 in tubing from the barbed fitting to the back of an oscillating fan, which helps spread CO2 around the room.
  • Open the flow knob about half a turn before opening the tank, then open the tank valve 2 or 3 turns.
  • Check every connection with soapy water for leaks.
  • Set the flow with the brass knob.
  • Never open it so far that the ball passes the top of the scale, since that can freeze the regulator.
  • Run CO2 only while the lights are on, and keep room levels below 2,500 PPM.
  • Titan covers the regulator against material defects for 1 year, and replacement washers are item 702712.
  • 0.5-15 SCFH Flowmeter: Visible ball indicator with a brass adjustment knob.
  • 120V Solenoid: Opens only when the controller or timer powers it.
  • Tank Pressure Gauge: Shows how much CO2 is left in the cylinder.
  • Controller Compatible: Atlas CO2 controllers, Apollo timers and wall timers.
  • Timing Chart Included: Run times by room volume and flow setting.
  • Technical Specifications

명세서

Flow Range
0.5-15 SCFH
Compatible Controls
Any 120 volt CO2 controller or timer
Tank Pressure Gauge
Shows how much CO2 is left in the cylinder.
Controller Compatible
Atlas CO2 controllers, Apollo timers and wall timers.

프로젝트에 도움이 되도록 만들어 봅시다.

문의 시 수량, 배송지, 재배 ​​지역, 전압 또는 플러그 요구 사항을 포함해 주십시오. 사양, 재고 여부, 배송 및 보증 조건은 서면 견적서에서 확인하실 수 있습니다.

저장된 환율을 사용한 참조 변환 (날짜 기준) 2026. 11. 15.. 환산된 금액은 견적이 아닙니다.

함께 성장해요

질문 및 토론

0

궁금한 점이 있거나 유용한 정보를 공유하고 싶으신가요? 대화를 시작해 보세요.

계속 탐험하세요

당신의 공간을 위한 더 많은 가능성

모든 제품 보기
좋은 일의 시작

당신의 프로젝트를 세상에 선보여 봅시다.

필요한 사항에 대해 간략하게 알려주세요. 고객님의 정보를 바탕으로 적절한 도매 견적을 준비해 드리겠습니다.

제품 목록

비용 부담이나 의무는 없습니다. 유익한 대화만 나누겠습니다.