이 콘텐츠는 현재 원어로 제공됩니다.
환기 및 온도 조절도매 문의
Titan Controls CO2 Regulator
모델/SKU: 702710
Titan Controls CO2 Regulator for Tank-Fed Grow Rooms
- Flow Range
- 0.5-15 SCFH
- Compatible Controls
- Any 120 volt CO2 controller or timer
- Tank Pressure Gauge
- Shows how much CO2 is left in the cylinder.
- Controller Compatible
- Atlas CO2 controllers, Apollo timers and wall timers.
출처 참조 가격KRW 138,816
비교 목적으로만 사용하십시오. 현재 도매 가격, 재고 여부 및 배송 조건을 문의하십시오.
결제는 필요하지 않습니다. 필요한 사항에 대해 이야기 나눠보세요.
공장 직송 지원15년 이상의 경력
자세히 살펴보기
이 제품에 대해 좀 더 자세히 알아보겠습니다.
Titan Controls CO2 Regulator for Tank-Fed Grow Rooms
Product details
- Enriching a sealed room with bottled CO2 starts at the tank, and this regulator is the piece that meters the gas out.
- Titan Controls item 702710 combines a tank pressure gauge, a flowmeter and a heavy-duty 120 volt solenoid in one body.
- The flowmeter reads from 0.5 to 15 standard cubic feet per hour, set with a brass flow adjustment knob.
- A ball rises and falls inside the clear tube, so the flow rate is visible at a glance.
- The solenoid opens only when it receives power, which lets a controller or timer decide when CO2 flows.
- That makes it compatible with any 120 volt CO2 controller or timer, including Titan's Atlas monitor/controllers and Apollo repeat cycle timers.
- With an Atlas controller, gas runs whenever the room drops below the PPM set point.
- With a timer, the regulator opens at set intervals based on room volume and flow rate.
- Titan's instructions include a timing chart for raising a room by about 1,100 to 1,200 PPM, to roughly 1,500 PPM total.
- For rooms over 2,000 cubic feet, the sheet gives a simple formula for working out run time.
- Installing a CO2 Regulator With Solenoid on the Tank
- Before connecting, crack the tank valve open for about 3 seconds to blow out any debris, then close it.
- Seat one of the white plastic washers inside the large brass nut to prevent leaks.
- Tighten the nut with a crescent wrench, not pliers, and do not hold the plastic flowmeter while tightening.
- Skip pipe thread tape and lubricants on the tank connection.
- Run the 1/4 in tubing from the barbed fitting to the back of an oscillating fan, which helps spread CO2 around the room.
- Open the flow knob about half a turn before opening the tank, then open the tank valve 2 or 3 turns.
- Check every connection with soapy water for leaks.
- Set the flow with the brass knob.
- Never open it so far that the ball passes the top of the scale, since that can freeze the regulator.
- Run CO2 only while the lights are on, and keep room levels below 2,500 PPM.
- Titan covers the regulator against material defects for 1 year, and replacement washers are item 702712.
- 0.5-15 SCFH Flowmeter: Visible ball indicator with a brass adjustment knob.
- 120V Solenoid: Opens only when the controller or timer powers it.
- Tank Pressure Gauge: Shows how much CO2 is left in the cylinder.
- Controller Compatible: Atlas CO2 controllers, Apollo timers and wall timers.
- Timing Chart Included: Run times by room volume and flow setting.
- Technical Specifications
명세서
- Flow Range
- 0.5-15 SCFH
- Compatible Controls
- Any 120 volt CO2 controller or timer
- Tank Pressure Gauge
- Shows how much CO2 is left in the cylinder.
- Controller Compatible
- Atlas CO2 controllers, Apollo timers and wall timers.
프로젝트에 도움이 되도록 만들어 봅시다.
문의 시 수량, 배송지, 재배 지역, 전압 또는 플러그 요구 사항을 포함해 주십시오. 사양, 재고 여부, 배송 및 보증 조건은 서면 견적서에서 확인하실 수 있습니다.
저장된 환율을 사용한 참조 변환 (날짜 기준) 2026. 11. 15.. 환산된 금액은 견적이 아닙니다.
계속 탐험하세요
모든 제품 보기당신의 공간을 위한 더 많은 가능성
환기 및 온도 조절
Yield Lab 6 inch 440 CFM Duct Inline Fan with 6" Carbon Filter Ducting and Clamps
출처 참조KRW 186,981
질문 및 토론
궁금한 점이 있거나 유용한 정보를 공유하고 싶으신가요? 대화를 시작해 보세요.