더 밝은 성장 방식. 공장 직송 도매. 15년 이상 축적된 전문성

이 콘텐츠는 현재 원어로 제공됩니다.

RH/Temp Smart Control, External probe: 2 Equipments

모델/SKU: NBIGS110S

How a Two Outlet Temperature and Humidity Controller Divides the Work

Voltage
120 V
Model
iGS-110
Type
Combined temperature and relative humidity controller
Equipment controlled
Two, on separate outlets
출처 참조 가격KRW 548,117

비교 목적으로만 사용하십시오. 현재 도매 가격, 재고 여부 및 배송 조건을 문의하십시오.

결제는 필요하지 않습니다. 필요한 사항에 대해 이야기 나눠보세요.

공장 직송 지원15년 이상의 경력
자세히 살펴보기

이 제품에 대해 좀 더 자세히 알아보겠습니다.

How a Two Outlet Temperature and Humidity Controller Divides the Work

Product details

  • One outlet for the condition you are heating or cooling, one for the condition you are wetting or drying.
  • That split is the whole design, and it is why this unit replaces two separate single task controllers.
  • Each outlet has its own target, so a heater and a dehumidifier stop fighting each other for the same reading.
  • It runs cooling, heating, humidifying, dehumidifying, or cooling and dehumidifying together.
  • Electrically it is 120 volts at 15 A, with a total load ceiling of 2 HP across both outlets.
  • That ceiling is the number to check first, because two large machines will exceed it long before the outlets do.
  • Day and night detection is built in, and each period carries its own pair of set points.
  • Operation priority is adjustable, which decides what happens when both conditions call at once.
  • So is the shutdown delay, which is what keeps a compressor from restarting into its own back pressure.
  • Why the External Probe Placement Decides Your Readings
  • An external probe on a lead is the reason this unit reads the room instead of reading itself.
  • A controller with the sensor inside its own case sits on a wall warmed by whatever is behind it.
  • Accuracy is plus or minus one degree Celsius on temperature and plus or minus 3.5 percent on relative humidity.
  • Those tolerances only hold where the probe hangs in moving air at canopy height.
  • Put it in the middle of the space, out of the discharge of anything it switches, and clear of the lights.
  • A probe in a dehumidifier's exhaust will hold the room far wetter than the display claims.
  • The four equipment version of this controller is a separate unit.
  • Anyone who needs to add carbon dioxide control needs a different model again.
  • This one does two jobs properly rather than four approximately.
  • Outlets: Two, one for temperature equipment and one for humidity
  • Modes: Cooling, heating, humidifying, drying, or cooling with drying
  • Probes: Both readings from external sensors on a lead
  • Temperature accuracy: Plus or minus one degree Celsius
  • Humidity accuracy: Plus or minus 3.5 percent relative humidity
  • Electrical: 120 volts, 15 A, 2 HP total load
  • Day and night: Detected automatically, with its own set points each
  • Adjustable: Operation priority and shutdown delay
  • Bigger version: A four equipment model exists as a separate unit

명세서

Model
iGS-110
Type
Combined temperature and relative humidity controller
Equipment controlled
Two, on separate outlets
Temperature sensor
External probe, accuracy plus or minus 1 degree Celsius
Humidity sensor
External probe, accuracy plus or minus 3.5 percent
Voltage
120 V
Current
15 A
Larger model
The four equipment version is a separate product
Temperature accuracy
Plus or minus one degree Celsius
Humidity accuracy
Plus or minus 3.5 percent relative humidity

프로젝트에 도움이 되도록 만들어 봅시다.

문의 시 수량, 배송지, 재배 ​​지역, 전압 또는 플러그 요구 사항을 포함해 주십시오. 사양, 재고 여부, 배송 및 보증 조건은 서면 견적서에서 확인하실 수 있습니다.

저장된 환율을 사용한 참조 변환 (날짜 기준) 2026. 11. 15.. 환산된 금액은 견적이 아닙니다.

함께 성장해요

질문 및 토론

0

궁금한 점이 있거나 유용한 정보를 공유하고 싶으신가요? 대화를 시작해 보세요.

계속 탐험하세요

당신의 공간을 위한 더 많은 가능성

모든 제품 보기
좋은 일의 시작

당신의 프로젝트를 세상에 선보여 봅시다.

필요한 사항에 대해 간략하게 알려주세요. 고객님의 정보를 바탕으로 적절한 도매 견적을 준비해 드리겠습니다.

제품 목록

비용 부담이나 의무는 없습니다. 유익한 대화만 나누겠습니다.