Growlink SDI-12 Climate Sensor
모델/SKU: ESM3
Growlink SDI-12 Climate Sensor Built for PIC and Connect Controllers
- Power
- +12VDC (supplied through SDI-12 input)
- Temperature Range
- -40 to 60°C (-40 to 140°F)
- Temperature Accuracy
- ±0.5°C (±0.9°F at 5-60°C)
- Humidity Range
- 0 - 100% RH (non-condensing)
출처 참조 가격KRW 533,086
비교 목적으로만 사용하십시오. 현재 도매 가격, 재고 여부 및 배송 조건을 문의하십시오.
결제는 필요하지 않습니다. 필요한 사항에 대해 이야기 나눠보세요.
공장 직송 지원15년 이상의 경력
자세히 살펴보기
이 제품에 대해 좀 더 자세히 알아보겠습니다.
Growlink SDI-12 Climate Sensor Built for PIC and Connect Controllers
Product details
- The ESM-3 reports air temperature, humidity, VPD, photocell, and optional CO2 through one SDI-12 digital interface.
- Each SDI-12 input on a Precision Irrigation Controller supports one ESM-3 plus one substrate probe.
- A standalone PIC handles four climate sensors and four substrate probes at once.
- Temperature reads -40 to 60°C with ±0.5°C accuracy.
- Humidity tracks 0-100% RH non-condensing with ±3% accuracy between 20-80% RH at 25°C.
- Eco Climate Sensor With Onboard Compensation and Low Power Draw
- Optional CO2 measurement runs 0-5000 ppm with ±50 ppm + 2-3% accuracy.
- Onboard temperature and pressure compensation keeps the readings honest as the room swings through veg, bloom, and lights-out cycles.
- The sensor draws low current on +12VDC, so a single SDI-12 input on a PIC supplies both power and data with three conductors.
- Multiple ESM-3 readings can be averaged in the controller or kept separate for zone-by-zone canopy climate mapping.
- SDI-12 Digital Output: One three-conductor cable carries +12VDC, signal, and ground from the controller to the sensor body.
- Air T, RH, VPD, Photocell: Standard climate readings derived from the sensor's onboard array, with VPD computed on the controller side.
- Optional CO2 Channel: Adds 0-5000 ppm CO2 measurement with ±50 ppm + 2-3% of measured value accuracy.
- PIC and Connect Compatible: Wires to any Growlink SDI-12 input or any third-party SDI-12 data logger that follows the spec.
- Onboard Compensation: Temperature and pressure compensation keeps the CO2 and humidity readings stable across day and night swings.
- Technical Specifications
명세서
- Power
- +12VDC (supplied through SDI-12 input)
- Temperature Range
- -40 to 60°C (-40 to 140°F)
- Temperature Accuracy
- ±0.5°C (±0.9°F at 5-60°C)
- Humidity Range
- 0 - 100% RH (non-condensing)
- Humidity Accuracy
- ±3% RH at 25°C, 20-80% RH
- CO2 Range (Optional)
- 0 - 5000 ppm
- Wire Configuration
- Brown +12VDC / White signal / Blue ground (or equivalent color code)
- Compatible Controllers
- Precision Irrigation Controller (PIC), Connect Controller, any SDI-12 data logger
- PIC and Connect Compatible
- Wires to any Growlink SDI-12 input or any third-party SDI-12 data logger that follows the spec.