Product details

  • A pH probe is a consumable rather than a thing that breaks.
  • The glass and the reference junction change chemically as they work, and past a certain point no amount of cleaning brings the reading back.
  • The symptoms are consistent enough to name.
  • A number that takes longer and longer to settle.
  • A slow drift away from a known buffer.
  • A probe that will not hold a two point calibration after a proper clean.
  • Bluelab asks for calibration once a month, and more often under heavy use, continuous monitoring, or organic nutrients.
  • Between readings the tip lives in KCl storage solution, refreshed weekly.
  • A probe that has dried out is not automatically finished.
  • It needs rehydrating and a fresh two point calibration before the numbers mean anything again.
  • Fitting a Bluelab Guardian pH Probe or a Meter Probe
  • This is the same electrode across the range, so it goes into any Bluelab instrument with a BNC connection.
  • That covers the Combo meter, the handheld pH meters and the Guardian monitors.
  • The cable is 2 metres, or 6.6 feet, in a polycarbonate body with a waterproof joint.
  • The reference is double junction, which is what buys it a longer working life than a single junction electrode in a nutrient tank.
  • It is gel filled and non-refillable, so there is nothing to top up and nothing to service beyond cleaning.
  • Two limits are worth knowing in advance.
  • It works between 0 and 60°C.
  • It also wants a solution of 0.2 EC or above, so pure water and fresh reverse osmosis give it too little to read.
  • A probe holder with a suction cup and a KCl filled storage cap come in the box.
  • Fits the whole BNC range: Combo meters, handheld pH meters and Guardian monitors all take this probe.
  • Replace the probe, not the meter: A worn electrode is a consumable.
  • The instrument behind it is not.
  • Double junction reference: Longer working life in a nutrient tank than a single junction electrode.
  • Gel filled, non-refillable: Nothing to top up.
  • Cleaning is the whole of the maintenance.
  • 2 metre cable: Or 6.6 feet, in a polycarbonate body with a waterproof cable joint.
  • Needs 0.2 EC or above: Pure water and fresh reverse osmosis give the probe too little to read.

명세서

Connector
Standard BNC
Compatible With
Bluelab meters, monitors and controllers with a BNC connection
Cable Length
2 m / 6.6 ft
pH Range
0.0 to 14.0
Operating Temperature
0 to 60°C / 32 to 140°F
Calibration
Two point, once a month or more under heavy use

프로젝트에 도움이 되도록 만들어 봅시다.

문의 시 수량, 배송지, 재배 ​​지역, 전압 또는 플러그 요구 사항을 포함해 주십시오. 사양, 재고 여부, 배송 및 보증 조건은 서면 견적서에서 확인하실 수 있습니다.

저장된 환율을 사용한 참조 변환 (날짜 기준) 2026. 11. 15.. 환산된 금액은 견적이 아닙니다.

함께 성장해요

질문 및 토론

0

궁금한 점이 있거나 유용한 정보를 공유하고 싶으신가요? 대화를 시작해 보세요.

계속 탐험하세요

당신의 공간을 위한 더 많은 가능성

모든 제품 보기
좋은 일의 시작

당신의 프로젝트를 세상에 선보여 봅시다.

필요한 사항에 대해 간략하게 알려주세요. 고객님의 정보를 바탕으로 적절한 도매 견적을 준비해 드리겠습니다.

제품 목록

비용 부담이나 의무는 없습니다. 유익한 대화만 나누겠습니다.