이 콘텐츠는 현재 원어로 제공됩니다.
컨트롤러 및 계량기도매 문의
Autopilot CO2 Controller APC8200 · 15 ft Remote NDIR Sensor
모델/SKU: APC8200
What the Autopilot CO2 Controller Reads and Switches
- Unit dimensions
- 9.7 x 7.5 x 3.9 in
- Sensor cable length
- 15 ft
출처 참조 가격KRW 399,013
비교 목적으로만 사용하십시오. 현재 도매 가격, 재고 여부 및 배송 조건을 문의하십시오.
결제는 필요하지 않습니다. 필요한 사항에 대해 이야기 나눠보세요.
공장 직송 지원15년 이상의 경력
자세히 살펴보기
이 제품에 대해 좀 더 자세히 알아보겠습니다.
What the Autopilot CO2 Controller Reads and Switches
Product details
- The sensing element is a two-channel low-drift NDIR type, carried in a remote probe that also holds a photocell.
- That probe rides on a 15 ft data cable, so it can hang in the canopy while the box stays on a wall.
- Range on the CO2 function runs from 0 to 5000 ppm.
- That covers ambient outdoor air at one end and a heavily enriched sealed room at the other.
- Both the setpoint and the ppm deadband are adjustable.
- The deadband is what stops a generator short-cycling around the target, and it is the first setting worth thinking about.
- Readings land on a trend chart that records per minute, per hour, per day and per week.
- Memory holds up to seven days, and an adjustable zoom steps through those intervals.
- Green LED lights report the unit status at a glance.
- The unit measures 9.7 x 7.5 x 3.9 in and ships at 2.3 lb.
- Part number is APC8200, with UPC 638104020701 and GTIN-14 10638104020708.
- Setting Up a CO2 Controller for Grow Room Enrichment
- A co2 controller for grow room work only pays off once the room is genuinely sealed.
- Enrichment bleeds out of a leaky tent faster than any source can replace it, so weatherstripping comes before programming.
- Set the target for lights-on only, because plants stop fixing carbon in the dark and the gas just accumulates.
- The photocell in the probe handles that switch without a separate timer on the circuit.
- A wide deadband means fewer source starts and a slower swing, while a narrow one holds tighter and cycles more often.
- Most sealed rooms settle somewhere in between once the chart shows how fast they bleed down.
- That chart is the real diagnostic tool on this unit.
- A sawtooth that falls away quickly between fills points at a leak, or at an exhaust fan still running on its own timer.
- A flat line that never reaches target points at an undersized source or an empty tank.
- The fault codes are worth knowing before anything goes wrong.
- Err4 flags the infrared lamp and Err6 flags the sensor connection.
- Err7 is a temperature or humidity fault, while Err5 and Err8 are internal to the unit.
- Mount it where the display can be read and the outlet is easy to reach.
- Keep the probe clear of a burner discharge and out of the direct path of an intake fan.
- Two-channel NDIR sensor: A low-drift infrared reading rather than a chemical cell.
- 0 to 5000 ppm range: Covers ambient air through a heavily enriched sealed room.
명세서
- Sensor cable length
- 15 ft
- Unit dimensions
- 9.7 x 7.5 x 3.9 in
프로젝트에 도움이 되도록 만들어 봅시다.
문의 시 수량, 배송지, 재배 지역, 전압 또는 플러그 요구 사항을 포함해 주십시오. 사양, 재고 여부, 배송 및 보증 조건은 서면 견적서에서 확인하실 수 있습니다.
저장된 환율을 사용한 참조 변환 (날짜 기준) 2026. 11. 15.. 환산된 금액은 견적이 아닙니다.
계속 탐험하세요
모든 제품 보기
질문 및 토론
궁금한 점이 있거나 유용한 정보를 공유하고 싶으신가요? 대화를 시작해 보세요.