이 콘텐츠는 현재 원어로 제공됩니다.
환기 및 온도 조절도매 문의
8 inch Backdraft Damper
모델/SKU: VTBDD8
Where an 8 inch Backdraft Damper Earns Its Place
- Duct size
- Eight inches, which covers most single room extraction runs
- Duct diameter
- 8 in
- Type
- Round backdraft damper, duct insert
- Material
- Galvanized steel
출처 참조 가격KRW 34,938
비교 목적으로만 사용하십시오. 현재 도매 가격, 재고 여부 및 배송 조건을 문의하십시오.
결제는 필요하지 않습니다. 필요한 사항에 대해 이야기 나눠보세요.
공장 직송 지원15년 이상의 경력
자세히 살펴보기
이 제품에 대해 좀 더 자세히 알아보겠습니다.
Where an 8 inch Backdraft Damper Earns Its Place
Product details
- Eight inches is where a lot of single room extraction ends up.
- It is also the size where backflow starts costing money rather than merely being a nuisance.
- A duct this diameter moves a serious volume in either direction.
- With the fan off, an eight inch open run will let cold air, smell and roof dust travel back into a room all night.
- Sealed rooms lose their pressure relationship the same way.
- This damper stops that with two galvanized blades hung on independent hinges.
- Independence is the part to look for in any damper, because a shared shaft turns one stuck blade into two.
- The whole assembly inserts into the duct, so there is no flange, no adaptor and no transition piece.
- It installs in any orientation, which matters on a vertical riser as much as on a horizontal run.
- The Neoprene Gasket and What a Bad Seal Costs
- The blades close onto a neoprene perimeter gasket rather than onto bare steel.
- That choice does two jobs at once.
- It takes the clang out of a closure, which is a real consideration in a building where people sleep or work nearby.
- It also fills the gap that a metal edge always leaves.
- On a duct this size a thin gap around the circumference adds up to a meaningful leak.
- Keep the gasket in mind through the life of the installation.
- Dust builds on the sealing face, resin from a room carries into the duct, and a face that cannot seat cleanly leaks quietly for months.
- Wipe it when the filter is serviced.
- Atmosphere quote an opening requirement of four to eight hundredths of an inch of static pressure.
- Any reasonably specified eight inch fan exceeds that at full speed.
- Check it at the lowest speed the fan will actually be run, not at full.
- Duct size: Eight inches, which covers most single room extraction runs
- Function: Prevents backflow of cold air, odour and dust when the fan stops
- Blades: Two galvanized blades, each on an independent hinge
- Seal: Neoprene perimeter gasket, not a bare metal edge
- Noise: The gasket takes the clang out of every closure
- Leakage: A gasketed face closes the gap a metal edge always leaves
- Mounting: The assembly inserts into the duct with no flange needed
명세서
- Duct diameter
- 8 in
- Type
- Round backdraft damper, duct insert
- Material
- Galvanized steel
- Mounting
- The whole assembly inserts into the duct
- Opening pressure
- 0.04 to 0.08 in of static pressure
- Duct size
- Eight inches, which covers most single room extraction runs
- Noise
- The gasket takes the clang out of every closure
프로젝트에 도움이 되도록 만들어 봅시다.
문의 시 수량, 배송지, 재배 지역, 전압 또는 플러그 요구 사항을 포함해 주십시오. 사양, 재고 여부, 배송 및 보증 조건은 서면 견적서에서 확인하실 수 있습니다.
저장된 환율을 사용한 참조 변환 (날짜 기준) 2026. 11. 15.. 환산된 금액은 견적이 아닙니다.
계속 탐험하세요
모든 제품 보기당신의 공간을 위한 더 많은 가능성
환기 및 온도 조절
Yield Lab 6 inch 440 CFM Duct Inline Fan with 6" Carbon Filter Ducting and Clamps
출처 참조KRW 186,981
질문 및 토론
궁금한 점이 있거나 유용한 정보를 공유하고 싶으신가요? 대화를 시작해 보세요.