Where an 8 inch Backdraft Damper Earns Its Place

Duct size
Eight inches, which covers most single room extraction runs
Duct diameter
8 in
Type
Round backdraft damper, duct insert
Material
Galvanized steel
출처 참조 가격KRW 34,938

비교 목적으로만 사용하십시오. 현재 도매 가격, 재고 여부 및 배송 조건을 문의하십시오.

결제는 필요하지 않습니다. 필요한 사항에 대해 이야기 나눠보세요.

공장 직송 지원15년 이상의 경력
자세히 살펴보기

이 제품에 대해 좀 더 자세히 알아보겠습니다.

Where an 8 inch Backdraft Damper Earns Its Place

Product details

  • Eight inches is where a lot of single room extraction ends up.
  • It is also the size where backflow starts costing money rather than merely being a nuisance.
  • A duct this diameter moves a serious volume in either direction.
  • With the fan off, an eight inch open run will let cold air, smell and roof dust travel back into a room all night.
  • Sealed rooms lose their pressure relationship the same way.
  • This damper stops that with two galvanized blades hung on independent hinges.
  • Independence is the part to look for in any damper, because a shared shaft turns one stuck blade into two.
  • The whole assembly inserts into the duct, so there is no flange, no adaptor and no transition piece.
  • It installs in any orientation, which matters on a vertical riser as much as on a horizontal run.
  • The Neoprene Gasket and What a Bad Seal Costs
  • The blades close onto a neoprene perimeter gasket rather than onto bare steel.
  • That choice does two jobs at once.
  • It takes the clang out of a closure, which is a real consideration in a building where people sleep or work nearby.
  • It also fills the gap that a metal edge always leaves.
  • On a duct this size a thin gap around the circumference adds up to a meaningful leak.
  • Keep the gasket in mind through the life of the installation.
  • Dust builds on the sealing face, resin from a room carries into the duct, and a face that cannot seat cleanly leaks quietly for months.
  • Wipe it when the filter is serviced.
  • Atmosphere quote an opening requirement of four to eight hundredths of an inch of static pressure.
  • Any reasonably specified eight inch fan exceeds that at full speed.
  • Check it at the lowest speed the fan will actually be run, not at full.
  • Duct size: Eight inches, which covers most single room extraction runs
  • Function: Prevents backflow of cold air, odour and dust when the fan stops
  • Blades: Two galvanized blades, each on an independent hinge
  • Seal: Neoprene perimeter gasket, not a bare metal edge
  • Noise: The gasket takes the clang out of every closure
  • Leakage: A gasketed face closes the gap a metal edge always leaves
  • Mounting: The assembly inserts into the duct with no flange needed

명세서

Duct diameter
8 in
Type
Round backdraft damper, duct insert
Material
Galvanized steel
Mounting
The whole assembly inserts into the duct
Opening pressure
0.04 to 0.08 in of static pressure
Duct size
Eight inches, which covers most single room extraction runs
Noise
The gasket takes the clang out of every closure

프로젝트에 도움이 되도록 만들어 봅시다.

문의 시 수량, 배송지, 재배 ​​지역, 전압 또는 플러그 요구 사항을 포함해 주십시오. 사양, 재고 여부, 배송 및 보증 조건은 서면 견적서에서 확인하실 수 있습니다.

저장된 환율을 사용한 참조 변환 (날짜 기준) 2026. 11. 15.. 환산된 금액은 견적이 아닙니다.

함께 성장해요

질문 및 토론

0

궁금한 점이 있거나 유용한 정보를 공유하고 싶으신가요? 대화를 시작해 보세요.

계속 탐험하세요

당신의 공간을 위한 더 많은 가능성

모든 제품 보기
좋은 일의 시작

당신의 프로젝트를 세상에 선보여 봅시다.

필요한 사항에 대해 간략하게 알려주세요. 고객님의 정보를 바탕으로 적절한 도매 견적을 준비해 드리겠습니다.

제품 목록

비용 부담이나 의무는 없습니다. 유익한 대화만 나누겠습니다.