What the TrolMaster SA-NTC Is and How It Reads

Type
Replacement temperature sensor
Compatible controllers
Beta-2 and Beta-4
Light
Keep it shaded, since radiant heat makes a probe read high
Fan controller trap
Never hang it in the airstream of the fan it is controlling
出典参考価格JPY 5,020

参考情報としてのみご利用ください。現在の卸売価格、在庫状況、配送条件についてはお問い合わせください。

料金は一切不要です。お客様のニーズについてお話ししましょう。

工場直送サポート15年以上の経験
さらに詳しく見てみよう

この製品についてもう少し詳しく

What the TrolMaster SA-NTC Is and How It Reads

Product details

  • The letters describe the technology.
  • NTC stands for negative temperature coefficient, which means the resistance of the element drops as the temperature climbs.
  • There is no electronics in the probe at all.
  • The controller applies a small voltage, measures what comes back, and converts that resistance into a figure on the display.
  • That simplicity is why these probes last, and it is also why their failures look the way they do.
  • A cut or crushed lead reads as an open circuit.
  • A controller seeing an open circuit displays an extreme value or an error rather than a plausible wrong number.
  • A partly damaged cable is harder, because it can read plausibly and still be wrong by several degrees.
  • If a room is holding a temperature that does not match a separate thermometer, suspect the probe before suspecting the controller.
  • This part fits the Beta-2 and the Beta-4, both of which ship with one in the box.
  • Probe Placement, and the Feedback Trap on a Fan Controller
  • Where the probe hangs decides what the controller actually controls.
  • Put it at canopy height, since that is the air the crop is living in rather than the warmer layer at ceiling level.
  • Keep it out of direct lamp light.
  • A sensor absorbing radiant heat reads higher than the air around it, and the room then runs colder than intended.
  • Shade it or tuck it behind something opaque.
  • Now the trap specific to a fan controller.
  • Never hang the probe in the airstream of the fan the controller is driving.
  • Doing that creates a loop.
  • The fan blows cool air across its own sensor, the sensor reports that the room is fine, and the fan slows down.
  • The reading then climbs again and the fan surges.
  • The result is a fan that hunts constantly and a room that never settles.
  • Place it away from the fan and away from any duct discharge.
  • Secure the lead so it cannot be pulled, since a tug at the connector is how most of these fail.
  • Function: Replacement temperature probe for the Beta-2 and the Beta-4
  • Technology: A negative temperature coefficient thermistor
  • How it works: Resistance falls as temperature rises and the controller converts it
  • No electronics: Nothing active inside the probe, which is why they last

仕様

Type
Replacement temperature sensor
Compatible controllers
Beta-2 and Beta-4
Light
Keep it shaded, since radiant heat makes a probe read high
Fan controller trap
Never hang it in the airstream of the fan it is controlling

あなたのプロジェクトに役立てましょう

お問い合わせの際は、数量、配送先、栽培地域、電圧やプラグに関するご要望を明記してください。仕様、在庫状況、配送条件、保証条件は、書面による見積書にてご確認いただけます。

保存された為替レートを使用した参照換算 2026/11/15. 換算された金額は見積もりではありません。

一緒に成長しよう

質問とディスカッション

0

質問や役立つ情報があれば、ぜひ共有してください。会話を始めましょう。

探検を続けよう

空間の可能性がさらに広がります

すべての商品を見る
良いことの始まり

あなたのプロジェクトを世に知らしめましょう。

お客様のご要望について少しお聞かせください。いただいた情報をもとに、適切な卸売りのご提案をさせていただきます。

商品リスト

料金は一切かかりません。義務も一切ありません。ただ、有益な会話を楽しみたいだけです。