What the TrolMaster SA-NTC Is and How It Reads
- Type
- Replacement temperature sensor
- Compatible controllers
- Beta-2 and Beta-4
- Light
- Keep it shaded, since radiant heat makes a probe read high
- Fan controller trap
- Never hang it in the airstream of the fan it is controlling
出典参考価格JPY 5,020
参考情報としてのみご利用ください。現在の卸売価格、在庫状況、配送条件についてはお問い合わせください。
料金は一切不要です。お客様のニーズについてお話ししましょう。
工場直送サポート15年以上の経験
さらに詳しく見てみよう
この製品についてもう少し詳しく
What the TrolMaster SA-NTC Is and How It Reads
Product details
- The letters describe the technology.
- NTC stands for negative temperature coefficient, which means the resistance of the element drops as the temperature climbs.
- There is no electronics in the probe at all.
- The controller applies a small voltage, measures what comes back, and converts that resistance into a figure on the display.
- That simplicity is why these probes last, and it is also why their failures look the way they do.
- A cut or crushed lead reads as an open circuit.
- A controller seeing an open circuit displays an extreme value or an error rather than a plausible wrong number.
- A partly damaged cable is harder, because it can read plausibly and still be wrong by several degrees.
- If a room is holding a temperature that does not match a separate thermometer, suspect the probe before suspecting the controller.
- This part fits the Beta-2 and the Beta-4, both of which ship with one in the box.
- Probe Placement, and the Feedback Trap on a Fan Controller
- Where the probe hangs decides what the controller actually controls.
- Put it at canopy height, since that is the air the crop is living in rather than the warmer layer at ceiling level.
- Keep it out of direct lamp light.
- A sensor absorbing radiant heat reads higher than the air around it, and the room then runs colder than intended.
- Shade it or tuck it behind something opaque.
- Now the trap specific to a fan controller.
- Never hang the probe in the airstream of the fan the controller is driving.
- Doing that creates a loop.
- The fan blows cool air across its own sensor, the sensor reports that the room is fine, and the fan slows down.
- The reading then climbs again and the fan surges.
- The result is a fan that hunts constantly and a room that never settles.
- Place it away from the fan and away from any duct discharge.
- Secure the lead so it cannot be pulled, since a tug at the connector is how most of these fail.
- Function: Replacement temperature probe for the Beta-2 and the Beta-4
- Technology: A negative temperature coefficient thermistor
- How it works: Resistance falls as temperature rises and the controller converts it
- No electronics: Nothing active inside the probe, which is why they last
仕様
- Type
- Replacement temperature sensor
- Compatible controllers
- Beta-2 and Beta-4
- Light
- Keep it shaded, since radiant heat makes a probe read high
- Fan controller trap
- Never hang it in the airstream of the fan it is controlling