TrolMaster Replacement CO2 Sensor for Beta-8
モデル/SKU: SA-S8
What the TrolMaster SA-S8 Replaces in a BETA-8
- Type
- Replacement CO2 sensor head
- Compatible controller
- BETA-8 Digital CO2 PPM Controller
出典参考価格JPY 30,625
参考情報としてのみご利用ください。現在の卸売価格、在庫状況、配送条件についてはお問い合わせください。
料金は一切不要です。お客様のニーズについてお話ししましょう。
工場直送サポート15年以上の経験
さらに詳しく見てみよう
この製品についてもう少し詳しく
What the TrolMaster SA-S8 Replaces in a BETA-8
Product details
- On a BETA-8 the controller is a box on a wall and the sensor is a head on a lead hanging near the canopy.
- Everything that actually measures sits in that head.
- The sensing element is NDIR, accurate to plus or minus fifty parts per million.
- It sits on a sixteen foot cable, with a photocell built into the same head.
- That photocell is what stops carbon dioxide injection during the dark period.
- So this part carries two functions rather than one, and losing it costs both the reading and the night behaviour.
- The head is the component that lives in the room rather than on the wall, which is why it is the part that wears.
- It sits in warm humid air, it collects dust, and it is the thing that gets knocked when a canopy is moved.
- Making it a service part is the right design, and it means a controller with a drifting reading does not become scrap.
- When an NDIR Head Needs Replacing Rather Than Cleaning
- Infrared measurement drifts slowly over years rather than failing outright, and that is what makes a bad sensor hard to spot.
- Watch for three particular patterns.
- A reading that never moves regardless of injection or ventilation is the clearest, because room levels always move.
- A figure that sits implausibly low while a regulator runs continuously points the same way.
- So does one that sits high while a room is being flushed.
- Cross-check with a separate meter before spending anything, since a controller arguing with itself costs less to diagnose than to replace.
- Dust on the head is worth clearing first, gently and dry.
- Where the photocell is the failing half, the symptom is different again and easy to misread as a control fault.
- Injection that never begins under lamps, or never stops in darkness, points at the light sensing side rather than the gas side.
- Function: The replacement remote sensor head for a BETA-8 controller
- Two jobs: It carries both the gas measurement and the photocell
- Accuracy: An NDIR element, accurate to plus or minus fifty parts per million
- Cable: A sixteen foot lead
- Why it wears: The head lives in warm humid air and collects dust
- Drift symptom: A reading that never moves whatever the room is doing
- Photocell symptom: Injection that never starts under lamps or never stops at night
- Before replacing: Cross-check against a separate meter and clear dust gently
- Service part: A drifting sensor does not force a whole controller replacement
仕様
- Type
- Replacement CO2 sensor head
- Compatible controller
- BETA-8 Digital CO2 PPM Controller