このコンテンツは現在、元の言語で提供されています。
コントローラーとメーター卸売に関するお問い合わせ
TrolMaster Full Spectrum Quantum Sensor
モデル/SKU: MBS-PAR
TrolMaster MBS-PAR Full Spectrum Quantum Sensor for Hydro-X PPFD
- Model
- MBS-PAR
- Spectral Range
- 389-692 nm plus/minus 5 nm
- Connector
- RJ12 (Hydro-X / Hydro-X Plus / Hydro-X Pro)
- Compatibility
- TrolMaster Hydro-X HCS-1, Hydro-X Plus HCS-3, Hydro-X Pro HCS-2
出典参考価格JPY 74,112
参考情報としてのみご利用ください。現在の卸売価格、在庫状況、配送条件についてはお問い合わせください。
料金は一切不要です。お客様のニーズについてお話ししましょう。
工場直送サポート15年以上の経験
さらに詳しく見てみよう
この製品についてもう少し詳しく
TrolMaster MBS-PAR Full Spectrum Quantum Sensor for Hydro-X PPFD
Product details
- TrolMaster's MBS-PAR is the in-room PPFD sensor that lets a Hydro-X controller dim fixtures based on what is hitting the canopy.
- Not what the schedule says should be hitting.
- The full-spectrum quantum element reads 389-692 nm plus/minus 5 nm and captures in micromol/m2/s.
- It ties back into the controller over a standard RJ12 input.
- Closed-loop PPFD control is something a clock-driven schedule will never match.
- Why Closed-Loop PPFD Control Outperforms a Static Schedule
- Drivers drift.
- Lamps degrade.
- Reflective walls get stained over a long flower run.
- A fixture that delivered 900 micromol/m2/s in week 1 reads closer to 820 by week 14.
- Growers typically mount the MBS-PAR at canopy height and feed it back to a Hydro-X.
- The controller nudges dim levels up to hold the target — useful in any room where consistency matters more than a fixed dim percent.
- Spectral range: 389-692 nm plus/minus 5 nm — wider than the standard 400-700 nm PAR window for fuller spectrum capture
- Output: PPFD in micromol/m2/s direct to the Hydro-X controller, not a relative lux number
- Connector: RJ12 — same plug-and-play hookup as the rest of the TrolMaster sensor family
- Closed-loop control: Lets the Hydro-X dim fixtures dynamically against a target PPFD instead of a fixed dim percent
- Cost-effective: More accessible than a lab-grade Apogee while accurate enough for daily controller logic
- Technical Specifications
仕様
- Model
- MBS-PAR
- Spectral Range
- 389-692 nm plus/minus 5 nm
- Connector
- RJ12 (Hydro-X / Hydro-X Plus / Hydro-X Pro)
- Compatibility
- TrolMaster Hydro-X HCS-1, Hydro-X Plus HCS-3, Hydro-X Pro HCS-2
- Spectral range
- 389-692 nm plus/minus 5 nm — wider than the standard 400-700 nm PAR window for fuller spectrum capture
- Output
- PPFD in micromol/m2/s direct to the Hydro-X controller, not a relative lux number
あなたのプロジェクトに役立てましょう
お問い合わせの際は、数量、配送先、栽培地域、電圧やプラグに関するご要望を明記してください。仕様、在庫状況、配送条件、保証条件は、書面による見積書にてご確認いただけます。
保存された為替レートを使用した参照換算 2026/11/15. 換算された金額は見積もりではありません。
探検を続けよう
すべての商品を見る
質問とディスカッション
質問や役立つ情報があれば、ぜひ共有してください。会話を始めましょう。