より明るい成長の道。工場直送卸売。 15年以上にわたる専門知識の蓄積

このコンテンツは現在、元の言語で提供されています。

繁殖と植物の手入れ卸売に関するお問い合わせ

TrolMaster DSP-2 240V Program Device Station

モデル/SKU: DSP-2

How the TrolMaster DSP-2 Runs Timed Loads

Input voltage
100 to 240 VAC, 50/60 Hz
Output voltage
100 to 240 VAC, 50/60 Hz
Package size
85 x 80 x 90 mm
Model
DSP-2
出典参考価格JPY 14,025

参考情報としてのみご利用ください。現在の卸売価格、在庫状況、配送条件についてはお問い合わせください。

料金は一切不要です。お客様のニーズについてお話ししましょう。

工場直送サポート15年以上の経験
さらに詳しく見てみよう

この製品についてもう少し詳しく

How the TrolMaster DSP-2 Runs Timed Loads

Product details

  • This module turns a Hydro-X or Aqua-X controller into a scheduler for any device that runs on time.
  • It accepts 100 to 240 VAC at 50/60 Hz and switches the same voltage out to the load.
  • Output is rated at 10 A, enough for pumps, UV sterilisers, circulation gear and small lighting loads.
  • A single RJ12 socket carries the link back to the controller, where cycle and program schedules are set.
  • One press of the small addressing button pairs the station with the controller during setup.
  • The LED reads fast green when unpaired, slow green when paired and off, and solid green when the load is running.
  • A blinking red light signals an overload, and unplugging the station clears it.
  • Holding the override button switches the load on or off without touching the stored schedule.
  • The box holds the station, a 16 ft RJ12 cable, a 4 ft RJ12 cable and an RJ12 T-splitter.
  • Wiring a 240V Program Device Station Into a Grow Room
  • A 240V program device station suits rooms built on dedicated 240 V circuits, where every timed load shares the same supply.
  • Plug the station into its outlet, then plug the device into the station.
  • Run the long RJ12 cable from the controller and use the T-splitter to chain the next module along the line.
  • Press the addressing button once and wait for the slow green light before building the schedule.
  • Pumps with a high start-up draw deserve extra headroom below that figure.
  • Mount the station off the floor and away from spray, since it works in up to 90 percent humidity, not wet conditions.
  • Label each station with its address so a reset or swap goes quickly during a busy week.
  • Use the override during maintenance to stop a pump without editing the program.
  • Set up this way, timed equipment across the room follows one controller and one clock.
  • 100 to 240 VAC input and output: Works on 240 V room circuits at 50/60 Hz.
  • 10 A output: Handles pumps, sterilisers, fans and small lighting loads.
  • One-button addressing: Pairs with a Hydro-X or Aqua-X controller in seconds.
  • Status LED: Shows paired, running and overload states at a glance.
  • Manual override: Switches the load without changing the stored schedule.
  • Technical Specifications

仕様

Model
DSP-2
Input voltage
100 to 240 VAC, 50/60 Hz
Output voltage
100 to 240 VAC, 50/60 Hz
Output current
10 A
Compatible controllers
Hydro-X, Aqua-X
Connection
RJ12 socket
Package size
85 x 80 x 90 mm
Gross weight
0.34 kg
Status LED
Shows paired, running and overload states at a glance.

あなたのプロジェクトに役立てましょう

お問い合わせの際は、数量、配送先、栽培地域、電圧やプラグに関するご要望を明記してください。仕様、在庫状況、配送条件、保証条件は、書面による見積書にてご確認いただけます。

保存された為替レートを使用した参照換算 2026/11/15. 換算された金額は見積もりではありません。

一緒に成長しよう

質問とディスカッション

0

質問や役立つ情報があれば、ぜひ共有してください。会話を始めましょう。

探検を続けよう

空間の可能性がさらに広がります

すべての商品を見る
良いことの始まり

あなたのプロジェクトを世に知らしめましょう。

お客様のご要望について少しお聞かせください。いただいた情報をもとに、適切な卸売りのご提案をさせていただきます。

商品リスト