TrolMaster DSP-2 240V Program Device Station
モデル/SKU: DSP-2
How the TrolMaster DSP-2 Runs Timed Loads
- Input voltage
- 100 to 240 VAC, 50/60 Hz
- Output voltage
- 100 to 240 VAC, 50/60 Hz
- Package size
- 85 x 80 x 90 mm
- Model
- DSP-2
出典参考価格JPY 14,025
参考情報としてのみご利用ください。現在の卸売価格、在庫状況、配送条件についてはお問い合わせください。
料金は一切不要です。お客様のニーズについてお話ししましょう。
工場直送サポート15年以上の経験
さらに詳しく見てみよう
この製品についてもう少し詳しく
How the TrolMaster DSP-2 Runs Timed Loads
Product details
- This module turns a Hydro-X or Aqua-X controller into a scheduler for any device that runs on time.
- It accepts 100 to 240 VAC at 50/60 Hz and switches the same voltage out to the load.
- Output is rated at 10 A, enough for pumps, UV sterilisers, circulation gear and small lighting loads.
- A single RJ12 socket carries the link back to the controller, where cycle and program schedules are set.
- One press of the small addressing button pairs the station with the controller during setup.
- The LED reads fast green when unpaired, slow green when paired and off, and solid green when the load is running.
- A blinking red light signals an overload, and unplugging the station clears it.
- Holding the override button switches the load on or off without touching the stored schedule.
- The box holds the station, a 16 ft RJ12 cable, a 4 ft RJ12 cable and an RJ12 T-splitter.
- Wiring a 240V Program Device Station Into a Grow Room
- A 240V program device station suits rooms built on dedicated 240 V circuits, where every timed load shares the same supply.
- Plug the station into its outlet, then plug the device into the station.
- Run the long RJ12 cable from the controller and use the T-splitter to chain the next module along the line.
- Press the addressing button once and wait for the slow green light before building the schedule.
- Pumps with a high start-up draw deserve extra headroom below that figure.
- Mount the station off the floor and away from spray, since it works in up to 90 percent humidity, not wet conditions.
- Label each station with its address so a reset or swap goes quickly during a busy week.
- Use the override during maintenance to stop a pump without editing the program.
- Set up this way, timed equipment across the room follows one controller and one clock.
- 100 to 240 VAC input and output: Works on 240 V room circuits at 50/60 Hz.
- 10 A output: Handles pumps, sterilisers, fans and small lighting loads.
- One-button addressing: Pairs with a Hydro-X or Aqua-X controller in seconds.
- Status LED: Shows paired, running and overload states at a glance.
- Manual override: Switches the load without changing the stored schedule.
- Technical Specifications
仕様
- Model
- DSP-2
- Input voltage
- 100 to 240 VAC, 50/60 Hz
- Output voltage
- 100 to 240 VAC, 50/60 Hz
- Output current
- 10 A
- Compatible controllers
- Hydro-X, Aqua-X
- Connection
- RJ12 socket
- Package size
- 85 x 80 x 90 mm
- Gross weight
- 0.34 kg
- Status LED
- Shows paired, running and overload states at a glance.