RH/Temp Smart Control, External probe: 2 Equipments

モデル/SKU: NBIGS110S

How a Two Outlet Temperature and Humidity Controller Divides the Work

Voltage
120 V
Model
iGS-110
Type
Combined temperature and relative humidity controller
Equipment controlled
Two, on separate outlets
出典参考価格JPY 65,549

参考情報としてのみご利用ください。現在の卸売価格、在庫状況、配送条件についてはお問い合わせください。

料金は一切不要です。お客様のニーズについてお話ししましょう。

工場直送サポート15年以上の経験
さらに詳しく見てみよう

この製品についてもう少し詳しく

How a Two Outlet Temperature and Humidity Controller Divides the Work

Product details

  • One outlet for the condition you are heating or cooling, one for the condition you are wetting or drying.
  • That split is the whole design, and it is why this unit replaces two separate single task controllers.
  • Each outlet has its own target, so a heater and a dehumidifier stop fighting each other for the same reading.
  • It runs cooling, heating, humidifying, dehumidifying, or cooling and dehumidifying together.
  • Electrically it is 120 volts at 15 A, with a total load ceiling of 2 HP across both outlets.
  • That ceiling is the number to check first, because two large machines will exceed it long before the outlets do.
  • Day and night detection is built in, and each period carries its own pair of set points.
  • Operation priority is adjustable, which decides what happens when both conditions call at once.
  • So is the shutdown delay, which is what keeps a compressor from restarting into its own back pressure.
  • Why the External Probe Placement Decides Your Readings
  • An external probe on a lead is the reason this unit reads the room instead of reading itself.
  • A controller with the sensor inside its own case sits on a wall warmed by whatever is behind it.
  • Accuracy is plus or minus one degree Celsius on temperature and plus or minus 3.5 percent on relative humidity.
  • Those tolerances only hold where the probe hangs in moving air at canopy height.
  • Put it in the middle of the space, out of the discharge of anything it switches, and clear of the lights.
  • A probe in a dehumidifier's exhaust will hold the room far wetter than the display claims.
  • The four equipment version of this controller is a separate unit.
  • Anyone who needs to add carbon dioxide control needs a different model again.
  • This one does two jobs properly rather than four approximately.
  • Outlets: Two, one for temperature equipment and one for humidity
  • Modes: Cooling, heating, humidifying, drying, or cooling with drying
  • Probes: Both readings from external sensors on a lead
  • Temperature accuracy: Plus or minus one degree Celsius
  • Humidity accuracy: Plus or minus 3.5 percent relative humidity
  • Electrical: 120 volts, 15 A, 2 HP total load
  • Day and night: Detected automatically, with its own set points each
  • Adjustable: Operation priority and shutdown delay
  • Bigger version: A four equipment model exists as a separate unit

仕様

Model
iGS-110
Type
Combined temperature and relative humidity controller
Equipment controlled
Two, on separate outlets
Temperature sensor
External probe, accuracy plus or minus 1 degree Celsius
Humidity sensor
External probe, accuracy plus or minus 3.5 percent
Voltage
120 V
Current
15 A
Larger model
The four equipment version is a separate product
Temperature accuracy
Plus or minus one degree Celsius
Humidity accuracy
Plus or minus 3.5 percent relative humidity

あなたのプロジェクトに役立てましょう

お問い合わせの際は、数量、配送先、栽培地域、電圧やプラグに関するご要望を明記してください。仕様、在庫状況、配送条件、保証条件は、書面による見積書にてご確認いただけます。

保存された為替レートを使用した参照換算 2026/11/15. 換算された金額は見積もりではありません。

一緒に成長しよう

質問とディスカッション

0

質問や役立つ情報があれば、ぜひ共有してください。会話を始めましょう。

探検を続けよう

空間の可能性がさらに広がります

すべての商品を見る
良いことの始まり

あなたのプロジェクトを世に知らしめましょう。

お客様のご要望について少しお聞かせください。いただいた情報をもとに、適切な卸売りのご提案をさせていただきます。

商品リスト

料金は一切かかりません。義務も一切ありません。ただ、有益な会話を楽しみたいだけです。