Growlink Batch TankLINK Temperature Sensor

モデル/SKU: GL-LINK-TEMPSENSOR

Real-Time Nutrient Reads with the Growlink Batch TankLINK Temperature Sensor

Power
24VDC via TankLINK controller
Connection
Screw terminal block (labeled on transmitter)
Compatible Controller
Growlink Batch TankLINK (pH, EC, Temp, Level inputs)
Calibration
LCD wizard, paired with pH & EC probes
出典参考価格JPY 7,188

参考情報としてのみご利用ください。現在の卸売価格、在庫状況、配送条件についてはお問い合わせください。

料金は一切不要です。お客様のニーズについてお話ししましょう。

工場直送サポート15年以上の経験
さらに詳しく見てみよう

この製品についてもう少し詳しく

Real-Time Nutrient Reads with the Growlink Batch TankLINK Temperature Sensor

Product details

  • The Growlink Batch TankLINK Temperature Sensor reads nutrient solution temperature directly inside a batch tank or reservoir.
  • The probe ties into the Batch TankLINK controller's screw terminal block.
  • It reports continuously at 0.02°F resolution with ±3.6°F (±2°C) accuracy.
  • The controller itself operates from 50 to 122°F.
  • That range covers the 68–72°F target band most hydroponic crops respond to inside the root zone.
  • Drop the probe into calibration solution alongside the pH and EC probes during the LCD wizard.
  • It locks in for the run.
  • Wiring the TankLINK Temperature Probe into a Live Recirculation Loop
  • The sensor handles the temperature input on a controller that already measures pH, EC, and tank level on the same board.
  • Pair it with a chiller or in-line heater triggered by the TankLINK.
  • The nutrient solution temperature probe data then holds tighter to setpoint through lights-on heat spikes.
  • On drain-to-waste schedules, the temperature read alongside EC tells you whether morning-shot solubility issues are temperature-driven.
  • That separates a chiller problem from a recipe problem before you adjust the feed.
  • Plug-and-play wiring keeps a single-probe swap during teardown to a few minutes.
  • No driver shuffling — just the batch tank temperature probe back into the terminal block and a quick recalibrate.
  • Most rooms keep one spare on hand for summer runs when reservoir temps climb hardest, particularly in greenhouses without dedicated cooling.
  • ±3.6°F (±2°C) Accuracy: Tight enough to confirm the nutrient line stays inside the 68–72°F sweet spot.
  • 0.02°F Resolution: Picks up small drifts during lights-on spikes before they widen into a real swing.
  • Direct TankLINK Integration: Wires straight into the Batch TankLINK controller's labeled screw terminal block.
  • Calibration Wizard Compatible: Drops into the LCD wizard alongside pH and EC for a single calibration pass.
  • Plug-and-Play Replacement: Probe swap during teardown takes minutes — terminal block in, recalibrate, run.
  • Technical Specifications

仕様

Connection
Screw terminal block (labeled on transmitter)
Compatible Controller
Growlink Batch TankLINK (pH, EC, Temp, Level inputs)
Calibration
LCD wizard, paired with pH & EC probes
Power
24VDC via TankLINK controller
Direct TankLINK Integration
Wires straight into the Batch TankLINK controller's labeled screw terminal block.
Calibration Wizard Compatible
Drops into the LCD wizard alongside pH and EC for a single calibration pass.

あなたのプロジェクトに役立てましょう

お問い合わせの際は、数量、配送先、栽培地域、電圧やプラグに関するご要望を明記してください。仕様、在庫状況、配送条件、保証条件は、書面による見積書にてご確認いただけます。

保存された為替レートを使用した参照換算 2026/11/15. 換算された金額は見積もりではありません。

一緒に成長しよう

質問とディスカッション

0

質問や役立つ情報があれば、ぜひ共有してください。会話を始めましょう。

探検を続けよう

空間の可能性がさらに広がります

すべての商品を見る
良いことの始まり

あなたのプロジェクトを世に知らしめましょう。

お客様のご要望について少しお聞かせください。いただいた情報をもとに、適切な卸売りのご提案をさせていただきます。

商品リスト

料金は一切かかりません。義務も一切ありません。ただ、有益な会話を楽しみたいだけです。