このコンテンツは現在、元の言語で提供されています。
コントローラーとメーター卸売に関するお問い合わせ
Growlink Batch TankLINK Temperature Sensor
モデル/SKU: GL-LINK-TEMPSENSOR
Real-Time Nutrient Reads with the Growlink Batch TankLINK Temperature Sensor
- Power
- 24VDC via TankLINK controller
- Connection
- Screw terminal block (labeled on transmitter)
- Compatible Controller
- Growlink Batch TankLINK (pH, EC, Temp, Level inputs)
- Calibration
- LCD wizard, paired with pH & EC probes
出典参考価格JPY 7,188
参考情報としてのみご利用ください。現在の卸売価格、在庫状況、配送条件についてはお問い合わせください。
料金は一切不要です。お客様のニーズについてお話ししましょう。
工場直送サポート15年以上の経験
さらに詳しく見てみよう
この製品についてもう少し詳しく
Real-Time Nutrient Reads with the Growlink Batch TankLINK Temperature Sensor
Product details
- The Growlink Batch TankLINK Temperature Sensor reads nutrient solution temperature directly inside a batch tank or reservoir.
- The probe ties into the Batch TankLINK controller's screw terminal block.
- It reports continuously at 0.02°F resolution with ±3.6°F (±2°C) accuracy.
- The controller itself operates from 50 to 122°F.
- That range covers the 68–72°F target band most hydroponic crops respond to inside the root zone.
- Drop the probe into calibration solution alongside the pH and EC probes during the LCD wizard.
- It locks in for the run.
- Wiring the TankLINK Temperature Probe into a Live Recirculation Loop
- The sensor handles the temperature input on a controller that already measures pH, EC, and tank level on the same board.
- Pair it with a chiller or in-line heater triggered by the TankLINK.
- The nutrient solution temperature probe data then holds tighter to setpoint through lights-on heat spikes.
- On drain-to-waste schedules, the temperature read alongside EC tells you whether morning-shot solubility issues are temperature-driven.
- That separates a chiller problem from a recipe problem before you adjust the feed.
- Plug-and-play wiring keeps a single-probe swap during teardown to a few minutes.
- No driver shuffling — just the batch tank temperature probe back into the terminal block and a quick recalibrate.
- Most rooms keep one spare on hand for summer runs when reservoir temps climb hardest, particularly in greenhouses without dedicated cooling.
- ±3.6°F (±2°C) Accuracy: Tight enough to confirm the nutrient line stays inside the 68–72°F sweet spot.
- 0.02°F Resolution: Picks up small drifts during lights-on spikes before they widen into a real swing.
- Direct TankLINK Integration: Wires straight into the Batch TankLINK controller's labeled screw terminal block.
- Calibration Wizard Compatible: Drops into the LCD wizard alongside pH and EC for a single calibration pass.
- Plug-and-Play Replacement: Probe swap during teardown takes minutes — terminal block in, recalibrate, run.
- Technical Specifications
仕様
- Connection
- Screw terminal block (labeled on transmitter)
- Compatible Controller
- Growlink Batch TankLINK (pH, EC, Temp, Level inputs)
- Calibration
- LCD wizard, paired with pH & EC probes
- Power
- 24VDC via TankLINK controller
- Direct TankLINK Integration
- Wires straight into the Batch TankLINK controller's labeled screw terminal block.
- Calibration Wizard Compatible
- Drops into the LCD wizard alongside pH and EC for a single calibration pass.
あなたのプロジェクトに役立てましょう
お問い合わせの際は、数量、配送先、栽培地域、電圧やプラグに関するご要望を明記してください。仕様、在庫状況、配送条件、保証条件は、書面による見積書にてご確認いただけます。
保存された為替レートを使用した参照換算 2026/11/15. 換算された金額は見積もりではありません。
探検を続けよう
すべての商品を見る
質問とディスカッション
質問や役立つ情報があれば、ぜひ共有してください。会話を始めましょう。