Bluelab Replacement pH Probe

モデル/SKU: 716445

When to Fit a Bluelab Replacement pH Probe

Connector
Standard BNC
Compatible With
Bluelab meters, monitors and controllers with a BNC connection
Cable Length
2 m / 6.6 ft
pH Range
0.0 to 14.0
出典参考価格JPY 21,498

参考情報としてのみご利用ください。現在の卸売価格、在庫状況、配送条件についてはお問い合わせください。

料金は一切不要です。お客様のニーズについてお話ししましょう。

工場直送サポート15年以上の経験
さらに詳しく見てみよう

この製品についてもう少し詳しく

When to Fit a Bluelab Replacement pH Probe

Product details

  • A pH probe is a consumable rather than a thing that breaks.
  • The glass and the reference junction change chemically as they work, and past a certain point no amount of cleaning brings the reading back.
  • The symptoms are consistent enough to name.
  • A number that takes longer and longer to settle.
  • A slow drift away from a known buffer.
  • A probe that will not hold a two point calibration after a proper clean.
  • Bluelab asks for calibration once a month, and more often under heavy use, continuous monitoring, or organic nutrients.
  • Between readings the tip lives in KCl storage solution, refreshed weekly.
  • A probe that has dried out is not automatically finished.
  • It needs rehydrating and a fresh two point calibration before the numbers mean anything again.
  • Fitting a Bluelab Guardian pH Probe or a Meter Probe
  • This is the same electrode across the range, so it goes into any Bluelab instrument with a BNC connection.
  • That covers the Combo meter, the handheld pH meters and the Guardian monitors.
  • The cable is 2 metres, or 6.6 feet, in a polycarbonate body with a waterproof joint.
  • The reference is double junction, which is what buys it a longer working life than a single junction electrode in a nutrient tank.
  • It is gel filled and non-refillable, so there is nothing to top up and nothing to service beyond cleaning.
  • Two limits are worth knowing in advance.
  • It works between 0 and 60°C.
  • It also wants a solution of 0.2 EC or above, so pure water and fresh reverse osmosis give it too little to read.
  • A probe holder with a suction cup and a KCl filled storage cap come in the box.
  • Fits the whole BNC range: Combo meters, handheld pH meters and Guardian monitors all take this probe.
  • Replace the probe, not the meter: A worn electrode is a consumable.
  • The instrument behind it is not.
  • Double junction reference: Longer working life in a nutrient tank than a single junction electrode.
  • Gel filled, non-refillable: Nothing to top up.
  • Cleaning is the whole of the maintenance.
  • 2 metre cable: Or 6.6 feet, in a polycarbonate body with a waterproof cable joint.
  • Needs 0.2 EC or above: Pure water and fresh reverse osmosis give the probe too little to read.

仕様

Connector
Standard BNC
Compatible With
Bluelab meters, monitors and controllers with a BNC connection
Cable Length
2 m / 6.6 ft
pH Range
0.0 to 14.0
Operating Temperature
0 to 60°C / 32 to 140°F
Calibration
Two point, once a month or more under heavy use

あなたのプロジェクトに役立てましょう

お問い合わせの際は、数量、配送先、栽培地域、電圧やプラグに関するご要望を明記してください。仕様、在庫状況、配送条件、保証条件は、書面による見積書にてご確認いただけます。

保存された為替レートを使用した参照換算 2026/11/15. 換算された金額は見積もりではありません。