このコンテンツは現在、元の言語で提供されています。
繁殖と植物の手入れ卸売に関するお問い合わせ
Bluelab Replacement pH Probe
モデル/SKU: 716445
When to Fit a Bluelab Replacement pH Probe
- Connector
- Standard BNC
- Compatible With
- Bluelab meters, monitors and controllers with a BNC connection
- Cable Length
- 2 m / 6.6 ft
- pH Range
- 0.0 to 14.0
出典参考価格JPY 21,498
参考情報としてのみご利用ください。現在の卸売価格、在庫状況、配送条件についてはお問い合わせください。
料金は一切不要です。お客様のニーズについてお話ししましょう。
工場直送サポート15年以上の経験
さらに詳しく見てみよう
この製品についてもう少し詳しく
When to Fit a Bluelab Replacement pH Probe
Product details
- A pH probe is a consumable rather than a thing that breaks.
- The glass and the reference junction change chemically as they work, and past a certain point no amount of cleaning brings the reading back.
- The symptoms are consistent enough to name.
- A number that takes longer and longer to settle.
- A slow drift away from a known buffer.
- A probe that will not hold a two point calibration after a proper clean.
- Bluelab asks for calibration once a month, and more often under heavy use, continuous monitoring, or organic nutrients.
- Between readings the tip lives in KCl storage solution, refreshed weekly.
- A probe that has dried out is not automatically finished.
- It needs rehydrating and a fresh two point calibration before the numbers mean anything again.
- Fitting a Bluelab Guardian pH Probe or a Meter Probe
- This is the same electrode across the range, so it goes into any Bluelab instrument with a BNC connection.
- That covers the Combo meter, the handheld pH meters and the Guardian monitors.
- The cable is 2 metres, or 6.6 feet, in a polycarbonate body with a waterproof joint.
- The reference is double junction, which is what buys it a longer working life than a single junction electrode in a nutrient tank.
- It is gel filled and non-refillable, so there is nothing to top up and nothing to service beyond cleaning.
- Two limits are worth knowing in advance.
- It works between 0 and 60°C.
- It also wants a solution of 0.2 EC or above, so pure water and fresh reverse osmosis give it too little to read.
- A probe holder with a suction cup and a KCl filled storage cap come in the box.
- Fits the whole BNC range: Combo meters, handheld pH meters and Guardian monitors all take this probe.
- Replace the probe, not the meter: A worn electrode is a consumable.
- The instrument behind it is not.
- Double junction reference: Longer working life in a nutrient tank than a single junction electrode.
- Gel filled, non-refillable: Nothing to top up.
- Cleaning is the whole of the maintenance.
- 2 metre cable: Or 6.6 feet, in a polycarbonate body with a waterproof cable joint.
- Needs 0.2 EC or above: Pure water and fresh reverse osmosis give the probe too little to read.
仕様
- Connector
- Standard BNC
- Compatible With
- Bluelab meters, monitors and controllers with a BNC connection
- Cable Length
- 2 m / 6.6 ft
- pH Range
- 0.0 to 14.0
- Operating Temperature
- 0 to 60°C / 32 to 140°F
- Calibration
- Two point, once a month or more under heavy use
あなたのプロジェクトに役立てましょう
お問い合わせの際は、数量、配送先、栽培地域、電圧やプラグに関するご要望を明記してください。仕様、在庫状況、配送条件、保証条件は、書面による見積書にてご確認いただけます。
保存された為替レートを使用した参照換算 2026/11/15. 換算された金額は見積もりではありません。
探検を続けよう
すべての商品を見る
質問とディスカッション