より明るい成長の道。工場直送卸売。 15年以上にわたる専門知識の蓄積

このコンテンツは現在、元の言語で提供されています。

コントローラーとメーター卸売に関するお問い合わせ

Autopilot CO2 Controller APC8200 · 15 ft Remote NDIR Sensor

モデル/SKU: APC8200

What the Autopilot CO2 Controller Reads and Switches

Unit dimensions
9.7 x 7.5 x 3.9 in
Sensor cable length
15 ft
出典参考価格JPY 47,718

参考情報としてのみご利用ください。現在の卸売価格、在庫状況、配送条件についてはお問い合わせください。

料金は一切不要です。お客様のニーズについてお話ししましょう。

工場直送サポート15年以上の経験
さらに詳しく見てみよう

この製品についてもう少し詳しく

What the Autopilot CO2 Controller Reads and Switches

Product details

  • The sensing element is a two-channel low-drift NDIR type, carried in a remote probe that also holds a photocell.
  • That probe rides on a 15 ft data cable, so it can hang in the canopy while the box stays on a wall.
  • Range on the CO2 function runs from 0 to 5000 ppm.
  • That covers ambient outdoor air at one end and a heavily enriched sealed room at the other.
  • Both the setpoint and the ppm deadband are adjustable.
  • The deadband is what stops a generator short-cycling around the target, and it is the first setting worth thinking about.
  • Readings land on a trend chart that records per minute, per hour, per day and per week.
  • Memory holds up to seven days, and an adjustable zoom steps through those intervals.
  • Green LED lights report the unit status at a glance.
  • The unit measures 9.7 x 7.5 x 3.9 in and ships at 2.3 lb.
  • Part number is APC8200, with UPC 638104020701 and GTIN-14 10638104020708.
  • Setting Up a CO2 Controller for Grow Room Enrichment
  • A co2 controller for grow room work only pays off once the room is genuinely sealed.
  • Enrichment bleeds out of a leaky tent faster than any source can replace it, so weatherstripping comes before programming.
  • Set the target for lights-on only, because plants stop fixing carbon in the dark and the gas just accumulates.
  • The photocell in the probe handles that switch without a separate timer on the circuit.
  • A wide deadband means fewer source starts and a slower swing, while a narrow one holds tighter and cycles more often.
  • Most sealed rooms settle somewhere in between once the chart shows how fast they bleed down.
  • That chart is the real diagnostic tool on this unit.
  • A sawtooth that falls away quickly between fills points at a leak, or at an exhaust fan still running on its own timer.
  • A flat line that never reaches target points at an undersized source or an empty tank.
  • The fault codes are worth knowing before anything goes wrong.
  • Err4 flags the infrared lamp and Err6 flags the sensor connection.
  • Err7 is a temperature or humidity fault, while Err5 and Err8 are internal to the unit.
  • Mount it where the display can be read and the outlet is easy to reach.
  • Keep the probe clear of a burner discharge and out of the direct path of an intake fan.
  • Two-channel NDIR sensor: A low-drift infrared reading rather than a chemical cell.
  • 0 to 5000 ppm range: Covers ambient air through a heavily enriched sealed room.

仕様

Sensor cable length
15 ft
Unit dimensions
9.7 x 7.5 x 3.9 in

あなたのプロジェクトに役立てましょう

お問い合わせの際は、数量、配送先、栽培地域、電圧やプラグに関するご要望を明記してください。仕様、在庫状況、配送条件、保証条件は、書面による見積書にてご確認いただけます。

保存された為替レートを使用した参照換算 2026/11/15. 換算された金額は見積もりではありません。

一緒に成長しよう

質問とディスカッション

0

質問や役立つ情報があれば、ぜひ共有してください。会話を始めましょう。

探検を続けよう

空間の可能性がさらに広がります

すべての商品を見る
良いことの始まり

あなたのプロジェクトを世に知らしめましょう。

お客様のご要望について少しお聞かせください。いただいた情報をもとに、適切な卸売りのご提案をさせていただきます。

商品リスト

料金は一切かかりません。義務も一切ありません。ただ、有益な会話を楽しみたいだけです。