When a Beta-6 Needs a Replacement Humidity Sensor
- Beta-6 input
- 120 volts AC
- Current part number
- SA-H1 (supersedes SA-D1)
- Beta-6 output
- Relay
- Beta-6 weight
- 0.56 kg
Solo a scopo comparativo. Richiedete il vostro prezzo all'ingrosso aggiornato, la disponibilità e le condizioni di consegna.
Nessun pagamento richiesto. Una conversazione per capire di cosa hai bisogno.
Qualche informazione in più su questo prodotto
When a Beta-6 Needs a Replacement Humidity Sensor
Product details
- A humidity controller is only as good as the probe hanging off it, and probes age faster than the box they plug into.
- Grow room air is the hard case, because a sensor sitting in condensing humidity for years will read low and keep reading low.
- The usual symptom is a dehumidifier that runs longer than it used to for the same room feel.
- Swapping the probe is the low cost test to run before anyone suspects the controller.
- The Beta-6 itself is a legacy unit in the TrolMaster range, so a spare probe keeps a working controller in service.
- The controller uses a precision sensor in a 16 ft remote probe, switching connected equipment through an outlet.
- This spare now carries the part number SA-H1 rather than SA-D1, which is worth knowing when cross referencing an older unit.
- What the Beta-6 Does With It, Day and Night
- The controller holds two humidity targets and a built in photocell decides which one applies.
- Day and night set points run from 20 to 90 percent relative humidity, with a five point deadband between switching on and off.
- That deadband is what stops a humidifier short cycling around a single number.
- A photocell means the changeover follows room light rather than a clock, so it tracks a lighting schedule automatically.
- It drives either a humidifier or a dehumidifier, not both at once.
- The probe feeds all of that, which is why a drifted sensor shows up as a room that never settles.
- Hang the probe at canopy height and clear of direct airflow from the unit it controls.
- A probe in the dehumidifier's own discharge reads the machine rather than the room.
- Keep the lead out of standing water even though the unit is rated for a normal room.
- The controller weighs about 0.56 kg and measures 275 mm by 87 mm, for anyone planning a wall position.
- What this is: The spare humidity probe alone, not a controller
- For: The TrolMaster Beta-6 day and night humidity controller
- Part code: SA-H1, superseding SA-D1
- Probe lead: The Beta-6 probe is a 16 ft remote lead
- Why replace: An aged probe reads low and overruns equipment
- Controller set points: 20 to 90 percent, separate day and night values
- Deadband: Five points, which prevents short cycling
- Day or night sensing: A built in photocell, not a clock
- Controller electrical: 120 volts in, relay output, 10 A fuse at 250 volts
- Technical Specifications
Specifiche
- Current part number
- SA-H1 (supersedes SA-D1)
- Beta-6 input
- 120 volts AC
- Beta-6 output
- Relay
- Beta-6 weight
- 0.56 kg
Facciamo in modo che funzioni per il tuo progetto
Nella tua richiesta, specifica la quantità, l'indirizzo di consegna, la zona di coltivazione e qualsiasi esigenza relativa a voltaggio o spina. Specifiche, disponibilità, spedizione e termini di garanzia saranno confermati nel preventivo scritto.
Conversione di riferimento utilizzando il tasso di cambio salvato datato 15 nov 2026. Gli importi convertiti non costituiscono un preventivo.
Maggiori possibilità per il tuo spazio
Yield Lab Heat Mat Thermostat Temperature Controller
Domande e discussione
Hai una domanda o qualcosa di utile da condividere? Avvia la conversazione.