Questo contenuto è attualmente disponibile nella sua lingua originale.
Sensorex pH Sensor
Modello / SKU: pH6000
Reading pH with the Growlink Sensorex pH Sensor
- SIZE
- 10' Cable, 30' Cable
- pH Range
- 0–14 pH
- Operating Temperature
- 0–80 °C (32–176 °F)
- Body Material
- Ultem® polymer
Solo a scopo comparativo. Richiedete il vostro prezzo all'ingrosso aggiornato, la disponibilità e le condizioni di consegna.
Nessun pagamento richiesto. Una conversazione per capire di cosa hai bisogno.
Qualche informazione in più su questo prodotto
Reading pH with the Growlink Sensorex pH Sensor
Product details
- The Growlink Sensorex pH Sensor reads 0–14 pH on a 12 mm Ultem-body electrode designed for samples where contamination would foul a single-junction probe.
- The double junction reference design isolates the Ag/AgCl reference cell behind a second junction filled with KCl.
- Heavy metals and organic compounds have to migrate through both junctions before they reach the reference wire.
- That extra barrier extends working life in nutrient solutions and recirculating fertigation lines where dissolved salts climb fast.
- Operating range is 0–80°C with sealed gel reference electrolyte.
- No top-up, no fill cap, low maintenance through the run.
- Cable, BNC, and Calibration for the Double Junction pH Probe
- Terminations are BNC at the meter end and Ultem at the wet end.
- The BNC connector plugs into any meter that accepts the standard fit, including the Growlink Batch TankLINK controller.
- Two cable lengths cover most reservoir layouts.
- The 10 ft cable handles bench-mounted controllers within reach of the tank.
- The 30 ft cable handles wall-mounted setups across the room.
- Both variants use the same Sensorex S200CD pH sensor head.
- The only spec difference is the cable run from probe to controller.
- The pH bulb sits recessed inside the polymer body so the glass doesn't crack against the bottom of a beaker or calibration cup.
- This double junction pH probe also resists silver-ion reference poisoning common in long-running recirculation systems.
- Run two-point calibration with pH 7 and pH 4 buffers at the start of each batch.
- Double Junction Reference: Second KCl-filled junction keeps heavy metals and sample contaminants away from the Ag/AgCl reference cell.
- Ultem® Polymer Body: Holds up to fertigation chemistry and field handling — won't crack like glass-body electrodes.
- Sealed Gel Reference: No top-up, no fill cap, no electrolyte maintenance across the run — pull, calibrate, replace.
- 0–14 pH Range, 0–80°C: Full pH scale across the operating temperature window that covers any indoor or greenhouse reservoir.
- BNC + Recessed pH Bulb: Standard BNC fit on TankLINK or any BNC meter; recessed glass tip resists impact damage at the beaker bottom.
- Technical Specifications
Specifiche
- pH Range
- 0–14 pH
- Operating Temperature
- 0–80 °C (32–176 °F)
- Body Material
- Ultem® polymer
- Diameter / Length
- 12 mm × 150 mm
- Connector
- BNC (booted BNC on the 30 ft variant)
- Cable Length Options
- 10 ft (3 m) or 30 ft (9 m)
- Calibration
- Two-point with pH 7.00 and pH 4.01 buffers
- Compatible Controllers
- Growlink Batch TankLINK and any BNC pH meter
- Sealed Gel Reference
- No top-up, no fill cap, no electrolyte maintenance across the run — pull, calibrate, replace.
- SIZE
- 10' Cable, 30' Cable
Facciamo in modo che funzioni per il tuo progetto
Nella tua richiesta, specifica la quantità, l'indirizzo di consegna, la zona di coltivazione e qualsiasi esigenza relativa a voltaggio o spina. Specifiche, disponibilità, spedizione e termini di garanzia saranno confermati nel preventivo scritto.
Conversione di riferimento utilizzando il tasso di cambio salvato datato 15 nov 2026. Gli importi convertiti non costituiscono un preventivo.
Maggiori possibilità per il tuo spazio
Yield Lab Heat Mat Thermostat Temperature Controller
Domande e discussione
Hai una domanda o qualcosa di utile da condividere? Avvia la conversazione.