Netafim Backflush Controller, 6 Outputs With DP Sensor, 24VAC, With Mounting Bracket
Modello / SKU: 00105-006220
Netafim Disc Filter Backflush Controller for Six-Filter Batteries
- Power Source
- 110 VAC 60 Hz or 220 VAC 50 Hz, built-in 24VAC supply
- Dimensions
- 9-1/2 in H x 5-5/8 in L x 3-1/4 in D
- Model
- 31NBCAC6
- Outputs
- 6, 24VAC solenoids
Solo a scopo comparativo. Richiedete il vostro prezzo all'ingrosso aggiornato, la disponibilità e le condizioni di consegna.
Nessun pagamento richiesto. Una conversazione per capire di cosa hai bisogno.
Qualche informazione in più su questo prodotto
Netafim Disc Filter Backflush Controller for Six-Filter Batteries
Product details
- A long disc filter battery at an irrigation head loads up faster than any one person can watch it.
- Netafim model 31NBCAC6, item 00105-006220, flushes up to six of those filters one after another on 24VAC solenoids.
- A built-in supply converts 110 VAC at 60 Hz or 220 VAC at 50 Hz to the 24 volts the coils need.
- The six outputs come on three plug-in cards, and Netafim's 2-output AC card, model 31NBCACCARD, adds more up to 10.
- Flushing begins when the embedded sensor sees the pressure drop reach its set point, or when the interval timer runs out.
- Netafim also lists the controller for automatic sand media and screen filters.
- Pressure shows in bar or psi, chosen during configuration.
- The set point covers 0.1 to 2.0 bar, which equals 1 to 30 psi.
- A downstream pressure sustaining valve, a delay valve and an alarm can each be given an output.
- The controller weighs 1.3 lb and comes with its mounting bracket.
- Reading the 6 Station 24VAC Flush Controller Display
- The top of the LCD shows actual DP, with the DP set point beneath it.
- Flush time per station sits at the lower left, and the flush mode at the lower right.
- Flush mode reads OFF, a time interval, or dp when only the sensor starts cycles.
- Hold the plus and minus keys together to see the time left until the next flush.
- A dedicated icon appears whenever a cycle has been started by hand from the MANUAL key.
- Three running totals record cycles started by DP, by the timer and by hand.
- Clear any of them with the plus or minus key when starting a new season's log.
- The final configuration screen gives the controller's software version for service calls.
- A blinking P means the low-pressure input has closed and the controller has paused.
- Operation is rated from 32 to 140°F, and the housing stands 9-1/2 in tall.
- Six 24VAC outputs: Three plug-in cards; up to 10 with 31NBCACCARD.
- 110 or 220 VAC supply: Built-in conversion to 24VAC.
- Embedded DP sensor: Set point 0.1-2.0 bar or 1-30 psi.
- Clear LCD readout: Actual DP, set point, flush time and mode on one screen.
- Three cycle counters: Separate totals for DP, timed and manual flushes.
- Mounting bracket: Comes with the controller.
- Technical Specifications
Specifiche
- Model
- 31NBCAC6
- Outputs
- 6, 24VAC solenoids
- Power Source
- 110 VAC 60 Hz or 220 VAC 50 Hz, built-in 24VAC supply
- Pressure Units
- Bar or psi
- Optional Outputs
- Main / pressure sustaining valve, delay valve, alarm
- Operating Temperature
- 32-140°F (0-60°C)
- Dimensions
- 9-1/2 in H x 5-5/8 in L x 3-1/4 in D
- Weight
- 1.3 lb
- Three cycle counters
- Separate totals for DP, timed and manual flushes.
- Mounting bracket
- Comes with the controller.
Facciamo in modo che funzioni per il tuo progetto
Nella tua richiesta, specifica la quantità, l'indirizzo di consegna, la zona di coltivazione e qualsiasi esigenza relativa a voltaggio o spina. Specifiche, disponibilità, spedizione e termini di garanzia saranno confermati nel preventivo scritto.
Conversione di riferimento utilizzando il tasso di cambio salvato datato 15 nov 2026. Gli importi convertiti non costituiscono un preventivo.
Maggiori possibilità per il tuo spazio
Yield Lab Heat Mat Thermostat Temperature Controller
Domande e discussione
Hai una domanda o qualcosa di utile da condividere? Avvia la conversazione.