Questo contenuto è attualmente disponibile nella sua lingua originale.
GF EC Probe (For NDS, NDK)
Modello / SKU: 3-2850-52-41V
PVDF Conductivity Electrode for the Growlink Nutrient Doser System
- Output
- 4-20 mA, two-wire (eight pre-set ranges per cell)
- Process connection
- 3/4 in NPT
- Calibration
- EasyCal auto-recognition (±10% of standard solution)
- Compatibility
- Growlink Nutrient Doser System (NDS), Nutrient Doser Kit (NDK), Connect Controller, generic 4-20 mA PLC
Solo a scopo comparativo. Richiedete il vostro prezzo all'ingrosso aggiornato, la disponibilità e le condizioni di consegna.
Nessun pagamento richiesto. Una conversazione per capire di cosa hai bisogno.
Qualche informazione in più su questo prodotto
PVDF Conductivity Electrode for the Growlink Nutrient Doser System
Product details
- The 2841 electrode pairs a PVDF insulator with 316 SS contacts and FKM internal O-rings.
- The wetted side handles standard hydroponic feeds without crazing.
- The 1.0 cell constant covers 10 to 10,000 µS — the band where fertigation EC actually sits.
- The 3/4 in NPT thread drops into any inline tee or submersion saddle.
- A 15-foot factory cable connects the electrode to the 2850 electronics.
- Up to 1,000 feet of cable runs between the electronics and the receiving controller.
- GF Signet 2850 Conductivity Sensor Electronics with EasyCal
- The 2850 is a two-wire transmitter that reports EC on a 4-20 mA loop.
- Eight pre-set ranges key to each cell constant — pick the band that matches your recipe and the loop scales automatically.
- EasyCal auto-recognizes a standard calibration solution within ±10% of its known value.
- A routine calibration takes a beaker of solution and a button press.
- The NEMA 4X / IP65 enclosure ignores wash-down and humidity.
- The 4-20 mA output lands on a Growlink Nutrient Doser, Connect Controller, or any PLC that reads a standard loop.
- 2841 PVDF electrode, 1.0 cell constant: 316 SS contacts and FKM O-rings handle 10 to 10,000 µS — the band fertigation actually lives in.
- 3/4 in NPT process connection: Threads into any standard inline tee or submersion saddle without an adapter.
- 4-20 mA two-wire output: Eight pre-set ranges per cell constant scale the loop to the recipe band.
- EasyCal auto-recognition: Beaker calibration with any standard solution within ±10% of the known value, no menu diving.
- NEMA 4X / IP65 enclosure: Sealed against wash-down and humid grow-room air on a wall or a mechanical-room shelf.
- Up to 1,000 ft electronics-to-controller cable run: Place the head where the line lives and the loop where the PLC can see it.
- Specified for Growlink NDS and NDK dosing systems: Drop-in EC sensor for the Nutrient Doser System and Nutrient Doser Kit.
- Technical Specifications
Specifiche
- Output
- 4-20 mA, two-wire (eight pre-set ranges per cell)
- Process connection
- 3/4 in NPT
- Calibration
- EasyCal auto-recognition (±10% of standard solution)
- Compatibility
- Growlink Nutrient Doser System (NDS), Nutrient Doser Kit (NDK), Connect Controller, generic 4-20 mA PLC
Facciamo in modo che funzioni per il tuo progetto
Nella tua richiesta, specifica la quantità, l'indirizzo di consegna, la zona di coltivazione e qualsiasi esigenza relativa a voltaggio o spina. Specifiche, disponibilità, spedizione e termini di garanzia saranno confermati nel preventivo scritto.
Conversione di riferimento utilizzando il tasso di cambio salvato datato 15 nov 2026. Gli importi convertiti non costituiscono un preventivo.
Maggiori possibilità per il tuo spazio
‘Wood Lovr’ Organic Hardwood-Based Sterile Mushroom Substrate
‘Boomr Bag’ Manure-Based Sterile Mushroom Bulk Substrate
Domande e discussione
Hai una domanda o qualcosa di utile da condividere? Avvia la conversazione.