Bluelab Replacement pH Probe
Modello / SKU: 716445
When to Fit a Bluelab Replacement pH Probe
- Connector
- Standard BNC
- Compatible With
- Bluelab meters, monitors and controllers with a BNC connection
- Cable Length
- 2 m / 6.6 ft
- pH Range
- 0.0 to 14.0
Solo a scopo comparativo. Richiedete il vostro prezzo all'ingrosso aggiornato, la disponibilità e le condizioni di consegna.
Nessun pagamento richiesto. Una conversazione per capire di cosa hai bisogno.
Qualche informazione in più su questo prodotto
When to Fit a Bluelab Replacement pH Probe
Product details
- A pH probe is a consumable rather than a thing that breaks.
- The glass and the reference junction change chemically as they work, and past a certain point no amount of cleaning brings the reading back.
- The symptoms are consistent enough to name.
- A number that takes longer and longer to settle.
- A slow drift away from a known buffer.
- A probe that will not hold a two point calibration after a proper clean.
- Bluelab asks for calibration once a month, and more often under heavy use, continuous monitoring, or organic nutrients.
- Between readings the tip lives in KCl storage solution, refreshed weekly.
- A probe that has dried out is not automatically finished.
- It needs rehydrating and a fresh two point calibration before the numbers mean anything again.
- Fitting a Bluelab Guardian pH Probe or a Meter Probe
- This is the same electrode across the range, so it goes into any Bluelab instrument with a BNC connection.
- That covers the Combo meter, the handheld pH meters and the Guardian monitors.
- The cable is 2 metres, or 6.6 feet, in a polycarbonate body with a waterproof joint.
- The reference is double junction, which is what buys it a longer working life than a single junction electrode in a nutrient tank.
- It is gel filled and non-refillable, so there is nothing to top up and nothing to service beyond cleaning.
- Two limits are worth knowing in advance.
- It works between 0 and 60°C.
- It also wants a solution of 0.2 EC or above, so pure water and fresh reverse osmosis give it too little to read.
- A probe holder with a suction cup and a KCl filled storage cap come in the box.
- Fits the whole BNC range: Combo meters, handheld pH meters and Guardian monitors all take this probe.
- Replace the probe, not the meter: A worn electrode is a consumable.
- The instrument behind it is not.
- Double junction reference: Longer working life in a nutrient tank than a single junction electrode.
- Gel filled, non-refillable: Nothing to top up.
- Cleaning is the whole of the maintenance.
- 2 metre cable: Or 6.6 feet, in a polycarbonate body with a waterproof cable joint.
- Needs 0.2 EC or above: Pure water and fresh reverse osmosis give the probe too little to read.
Specifiche
- Connector
- Standard BNC
- Compatible With
- Bluelab meters, monitors and controllers with a BNC connection
- Cable Length
- 2 m / 6.6 ft
- pH Range
- 0.0 to 14.0
- Operating Temperature
- 0 to 60°C / 32 to 140°F
- Calibration
- Two point, once a month or more under heavy use
Facciamo in modo che funzioni per il tuo progetto
Nella tua richiesta, specifica la quantità, l'indirizzo di consegna, la zona di coltivazione e qualsiasi esigenza relativa a voltaggio o spina. Specifiche, disponibilità, spedizione e termini di garanzia saranno confermati nel preventivo scritto.
Conversione di riferimento utilizzando il tasso di cambio salvato datato 15 nov 2026. Gli importi convertiti non costituiscono un preventivo.
Maggiori possibilità per il tuo spazio
‘Wood Lovr’ Organic Hardwood-Based Sterile Mushroom Substrate
‘Boomr Bag’ Manure-Based Sterile Mushroom Bulk Substrate
Domande e discussione
Hai una domanda o qualcosa di utile da condividere? Avvia la conversazione.