Ce contenu est actuellement disponible dans sa langue d'origine.
TrolMaster DSP-2 240V Program Device Station
Modèle / UGS: DSP-2
How the TrolMaster DSP-2 Runs Timed Loads
- Input voltage
- 100 to 240 VAC, 50/60 Hz
- Output voltage
- 100 to 240 VAC, 50/60 Hz
- Package size
- 85 x 80 x 90 mm
- Model
- DSP-2
À titre indicatif seulement. Veuillez nous contacter pour connaître nos tarifs de gros actuels, la disponibilité des produits et les conditions de livraison.
Aucun paiement requis. Une simple discussion pour comprendre vos besoins.
Un peu plus d'informations sur ce produit
How the TrolMaster DSP-2 Runs Timed Loads
Product details
- This module turns a Hydro-X or Aqua-X controller into a scheduler for any device that runs on time.
- It accepts 100 to 240 VAC at 50/60 Hz and switches the same voltage out to the load.
- Output is rated at 10 A, enough for pumps, UV sterilisers, circulation gear and small lighting loads.
- A single RJ12 socket carries the link back to the controller, where cycle and program schedules are set.
- One press of the small addressing button pairs the station with the controller during setup.
- The LED reads fast green when unpaired, slow green when paired and off, and solid green when the load is running.
- A blinking red light signals an overload, and unplugging the station clears it.
- Holding the override button switches the load on or off without touching the stored schedule.
- The box holds the station, a 16 ft RJ12 cable, a 4 ft RJ12 cable and an RJ12 T-splitter.
- Wiring a 240V Program Device Station Into a Grow Room
- A 240V program device station suits rooms built on dedicated 240 V circuits, where every timed load shares the same supply.
- Plug the station into its outlet, then plug the device into the station.
- Run the long RJ12 cable from the controller and use the T-splitter to chain the next module along the line.
- Press the addressing button once and wait for the slow green light before building the schedule.
- Pumps with a high start-up draw deserve extra headroom below that figure.
- Mount the station off the floor and away from spray, since it works in up to 90 percent humidity, not wet conditions.
- Label each station with its address so a reset or swap goes quickly during a busy week.
- Use the override during maintenance to stop a pump without editing the program.
- Set up this way, timed equipment across the room follows one controller and one clock.
- 100 to 240 VAC input and output: Works on 240 V room circuits at 50/60 Hz.
- 10 A output: Handles pumps, sterilisers, fans and small lighting loads.
- One-button addressing: Pairs with a Hydro-X or Aqua-X controller in seconds.
- Status LED: Shows paired, running and overload states at a glance.
- Manual override: Switches the load without changing the stored schedule.
- Technical Specifications
Caractéristiques
- Model
- DSP-2
- Input voltage
- 100 to 240 VAC, 50/60 Hz
- Output voltage
- 100 to 240 VAC, 50/60 Hz
- Output current
- 10 A
- Compatible controllers
- Hydro-X, Aqua-X
- Connection
- RJ12 socket
- Package size
- 85 x 80 x 90 mm
- Gross weight
- 0.34 kg
- Status LED
- Shows paired, running and overload states at a glance.
Faisons en sorte que cela fonctionne pour votre projet.
Veuillez indiquer la quantité, le lieu de livraison, la zone de culture et toute exigence en matière de tension ou de prise dans votre demande. Les spécifications, la disponibilité, les modalités d'expédition et de garantie seront confirmées dans votre devis écrit.
Conversion de référence utilisant le taux de change enregistré à la date 15 nov. 2026. Les montants convertis ne constituent pas une cotation.
Plus de possibilités pour votre espace
‘Wood Lovr’ Organic Hardwood-Based Sterile Mushroom Substrate
‘Boomr Bag’ Manure-Based Sterile Mushroom Bulk Substrate
Questions et discussion
Vous avez une question ou quelque chose d'utile à partager ? Lancez la conversation.