Netafim Pulse Reed Switch
Modèle / UGS: 70220-005300
What a Pulse Reed Switch Adds to a Water Meter
- Power Required
- None, passive switch
- Volume Per Pulse
- Determined by the water meter it is fitted to
- Volume per pulse is set by the meter
- Netafim meters ship in different pulse values, so check the register before you scale readings.
À titre indicatif seulement. Veuillez nous contacter pour connaître nos tarifs de gros actuels, la disponibilité des produits et les conditions de livraison.
Aucun paiement requis. Une simple discussion pour comprendre vos besoins.
Un peu plus d'informations sur ce produit
What a Pulse Reed Switch Adds to a Water Meter
Product details
- A mechanical meter counts perfectly well and tells nobody.
- This register sits on the meter and adds an electrical output.
- No power is needed on the meter side, because the switch is passive.
- Reading the Water Meter Pulse Output at the Controller
- Any controller, datalogger or PLC with a digital input can take it, which is what makes a water meter pulse output so portable across equipment.
- The controller does the arithmetic: count the pulses, multiply by the volume each pulse represents, and you have consumption.
- That multiplier is set by the meter rather than by the switch, and Netafim meters are supplied in different pulse values.
- Check the register on the meter you are fitting, because getting that number wrong scales every reading you log.
- Two practical notes.
- Reed contacts are mechanical and they do eventually wear, which is the usual reason one gets replaced rather than a fault in the meter itself.
- And run the signal pair away from pump and light wiring, since a long unshielded run beside a contactor can pick up false counts.
- Passive, no power needed: The switch takes nothing on the meter side.
- The controller supplies the sensing circuit.
- Volume per pulse is set by the meter: Netafim meters ship in different pulse values, so check the register before you scale readings.
- A common replacement part: Reed contacts are mechanical and wear, which is usually why one is swapped.
- Keep the run clean: Route the signal pair away from pump and lighting wiring to avoid false counts.
- Technical Specifications
Caractéristiques
- Power Required
- None, passive switch
- Volume Per Pulse
- Determined by the water meter it is fitted to
- Volume per pulse is set by the meter
- Netafim meters ship in different pulse values, so check the register before you scale readings.
Faisons en sorte que cela fonctionne pour votre projet.
Veuillez indiquer la quantité, le lieu de livraison, la zone de culture et toute exigence en matière de tension ou de prise dans votre demande. Les spécifications, la disponibilité, les modalités d'expédition et de garantie seront confirmées dans votre devis écrit.
Conversion de référence utilisant le taux de change enregistré à la date 15 nov. 2026. Les montants convertis ne constituent pas une cotation.
Plus de possibilités pour votre espace
Yield Lab 600W HPS+MH Cool Tube Hood Reflector Grow Light Kit
Yield Lab 600W HPS+MH Air Cool Tube Reflector Digital Grow Light Kit
Questions et discussion
Vous avez une question ou quelque chose d'utile à partager ? Lancez la conversation.