Ce contenu est actuellement disponible dans sa langue d'origine.
12 inch Backdraft Damper
Modèle / UGS: VTBDD12
Sizing a 12 inch Backdraft Damper Into a Big Run
- Duct diameter
- 12 in
- Type
- Round backdraft damper, duct insert
- Material
- Galvanized steel
- Mounting
- The whole assembly inserts into the duct
À titre indicatif seulement. Veuillez nous contacter pour connaître nos tarifs de gros actuels, la disponibilité des produits et les conditions de livraison.
Aucun paiement requis. Une simple discussion pour comprendre vos besoins.
Un peu plus d'informations sur ce produit
Sizing a 12 inch Backdraft Damper Into a Big Run
Product details
- At twelve inches everything about a damper is bigger, including the consequences of getting it wrong.
- An open duct this size is a substantial hole in a building.
- With the fan off it moves cold air, odour and dust in the wrong direction continuously.
- On a room built around a pressure relationship, that undoes the whole design.
- The two blades here are correspondingly large plates, which is why the hinge arrangement matters.
- Each blade has its own hinge, so a blade that catches on debris does not hold its partner open with it.
- Galvanized steel keeps plates this size rigid enough to seat properly for years in a humid duct.
- A neoprene perimeter gasket takes the closure.
- On a plate this size that is the difference between a soft thud and a bang carrying through a building.
- Installing a Duct Insert of This Diameter
- The assembly pushes into the duct rather than mounting on a flange, which at this diameter saves genuine work.
- There is no transition piece to fabricate and nothing to line up beyond the duct itself.
- It installs in any orientation.
- Two things deserve attention at this size.
- Support the duct on both sides of the damper properly.
- A twelve inch run carries real weight, and a sagging duct distorts the housing until the blades no longer seat.
- The second is access to it afterwards.
- A damper buried in a ceiling void where nobody can reach it will eventually stop sealing and nobody will know.
- Atmosphere quote an opening requirement of four to eight hundredths of an inch of static pressure.
- A correctly specified twelve inch fan clears that easily at speed.
- Confirm it at low speed too.
- Check the swing and wipe the sealing face at every filter service.
- Why it matters: An open duct this size is a substantial hole in a building
- Blades: Two large plates, each on its own independent hinge
- Hinge design: A blade that catches cannot hold its partner open
- Body: Galvanized steel, stiff enough to keep large plates seating
- Seal: Neoprene perimeter gasket, which softens the closure
- Mounting: Inserts into the duct, with no transition piece to fabricate
Caractéristiques
- Duct diameter
- 12 in
- Type
- Round backdraft damper, duct insert
- Material
- Galvanized steel
- Mounting
- The whole assembly inserts into the duct
- Opening pressure
- 0.04 to 0.08 in of static pressure
- Support
- Hold the duct both sides so the housing cannot distort
Faisons en sorte que cela fonctionne pour votre projet.
Veuillez indiquer la quantité, le lieu de livraison, la zone de culture et toute exigence en matière de tension ou de prise dans votre demande. Les spécifications, la disponibilité, les modalités d'expédition et de garantie seront confirmées dans votre devis écrit.
Conversion de référence utilisant le taux de change enregistré à la date 15 nov. 2026. Les montants convertis ne constituent pas une cotation.
Plus de possibilités pour votre espace
Yield Lab 6 Inch Purifier Activated Charcoal Filter
Yield Lab 6 inch 440 CFM Duct Inline Fan with 6" Carbon Filter Ducting and Clamps
Yield Lab 6 Inch 440 CFM Charcoal Filter and Duct Fan Combo Kit
Questions et discussion