TrolMaster Dual System Control Adapter (DCC-2)

Modelo / SKU: DCC-2

TrolMaster DCC-2 Puts One Device Under Two Controllers

Input voltage
12 VAC
Package dimensions
6.14 × 3.27 × 1.18 in (156 × 83 × 30 mm)
Compatible modules
DSC-1, DSH-1/2, DST-1/2, DSP-1, DSD-1, DSV-1
Maximum current
0.2A
Precio de referencia de la fuenteEUR 94.68

Solo a título informativo. Solicite su precio mayorista actual, disponibilidad y condiciones de entrega.

No se requiere ningún pago. Una conversación sobre lo que necesitas.

Soporte directo de fábricaMás de 15 años de experiencia
UNA MIRADA MÁS DETALLADA

Un poco más sobre este producto

TrolMaster DCC-2 Puts One Device Under Two Controllers

Product details

  • A single exhaust fan often has more than one job in a grow room.
  • It may need to clear CO2 when levels run high and also run on a night-time schedule.
  • The DCC-2 lets two separate controllers share that one device instead of adding a second fan and module.
  • It plugs into one of TrolMaster's plug-in device stations through its built-in RJ12 lead.
  • Supported modules are the DSC-1, DSH-1/2, DST-1/2, DSP-1, DSD-1 and DSV-1.
  • Each side of the adapter, Section A and Section B, is addressed to a different controller.
  • A typical pairing puts a Hydro-X on one side and a Carbon-X on the other.
  • Each side can be registered as a temperature, humidity, CO2 or timer function.
  • Once linked, the adapter replaces the module's original preset with the functions you assign.
  • The package measures 6.14 × 3.27 × 1.18 in and weighs 0.11 lbs.
  • Series or Parallel: Setting the Dual System Control Adapter Interlock
  • The interlock setting decides how the two conditions combine.
  • With interlock on, both conditions must be true before the device runs, which is a series setup.
  • For example, an exhaust fan could run only when CO2 and humidity are both above setpoint.
  • With interlock off, either condition can start the device on its own, which is a parallel setup.
  • That suits a fan that should run for high CO2 or during a scheduled night-time air exchange.
  • Toggling the interlock on either section changes both sections together.
  • A quick press of Mode picks the module type, and holding it for three seconds resets the adapter.
  • A quick press of Add registers it with the controller, and holding Add for three seconds switches the interlock.
  • The reset button does not clear the link on HCS-2 or NFS-2 controllers, so use the controller menu there.
  • It is rated for rooms from 32 to 122°F at up to 90% relative humidity.
  • Two Controllers, One Module: Address Section A and Section B to separate controllers so both can drive the same device.
  • Series or Parallel Interlock: Choose whether both conditions or either condition switches the device on.
  • Four Function Types: Register each side as temperature, humidity, CO2 or timer control.
  • Built-In RJ12 Lead: Plugs straight into a supported plug-in device station with no extra cable.
  • Fewer Duplicate Devices: One fan or dehumidifier can serve two control strategies instead of a second unit.
  • Technical Specifications

Presupuesto

Compatible modules
DSC-1, DSH-1/2, DST-1/2, DSP-1, DSD-1, DSV-1
Input voltage
12 VAC
Maximum current
0.2A
Operating temperature
32–122°F (0–50°C)
Operating humidity
≤90% RH
Package contents
1 × DCC-2 adapter
Package dimensions
6.14 × 3.27 × 1.18 in (156 × 83 × 30 mm)
Gross weight
0.11 lbs (0.05 kg)
Series or Parallel
Setting the Dual System Control Adapter Interlock
Series or Parallel Interlock
Choose whether both conditions or either condition switches the device on.
Four Function Types
Register each side as temperature, humidity, CO2 or timer control.

Hagamos que funcione para tu proyecto.

En su consulta, incluya la cantidad, el destino de entrega, la zona de cultivo y cualquier requisito de voltaje o enchufe. Las especificaciones, la disponibilidad, el envío y las condiciones de garantía se confirmarán en su presupuesto por escrito.

Conversión de referencia utilizando el tipo de cambio guardado con fecha 15 nov 2026. Los importes convertidos no constituyen una cotización.

CREZCAMOS JUNTOS

Preguntas y debate

0

¿Tienes alguna pregunta o algo útil que compartir? Inicia la conversación.

SIGUE EXPLORANDO

Más posibilidades para tu espacio

Ver todos los productos
EL COMIENZO DE ALGO BUENO

Vamos a sacar tu proyecto a la luz.

Cuéntenos brevemente qué necesita. Utilizaremos sus datos para preparar una respuesta mayorista adecuada.

Lista de productos

Sin pago. Sin compromiso. Simplemente una conversación útil.