What a Pulse Reed Switch Adds to a Water Meter
- Power Required
- None, passive switch
- Volume Per Pulse
- Determined by the water meter it is fitted to
- Volume per pulse is set by the meter
- Netafim meters ship in different pulse values, so check the register before you scale readings.
Precio de referencia de la fuenteEUR 64.12
Solo a título informativo. Solicite su precio mayorista actual, disponibilidad y condiciones de entrega.
No se requiere ningún pago. Una conversación sobre lo que necesitas.
Soporte directo de fábricaMás de 15 años de experiencia
UNA MIRADA MÁS DETALLADA
Un poco más sobre este producto
What a Pulse Reed Switch Adds to a Water Meter
Product details
- A mechanical meter counts perfectly well and tells nobody.
- This register sits on the meter and adds an electrical output.
- No power is needed on the meter side, because the switch is passive.
- Reading the Water Meter Pulse Output at the Controller
- Any controller, datalogger or PLC with a digital input can take it, which is what makes a water meter pulse output so portable across equipment.
- The controller does the arithmetic: count the pulses, multiply by the volume each pulse represents, and you have consumption.
- That multiplier is set by the meter rather than by the switch, and Netafim meters are supplied in different pulse values.
- Check the register on the meter you are fitting, because getting that number wrong scales every reading you log.
- Two practical notes.
- Reed contacts are mechanical and they do eventually wear, which is the usual reason one gets replaced rather than a fault in the meter itself.
- And run the signal pair away from pump and light wiring, since a long unshielded run beside a contactor can pick up false counts.
- Passive, no power needed: The switch takes nothing on the meter side.
- The controller supplies the sensing circuit.
- Volume per pulse is set by the meter: Netafim meters ship in different pulse values, so check the register before you scale readings.
- A common replacement part: Reed contacts are mechanical and wear, which is usually why one is swapped.
- Keep the run clean: Route the signal pair away from pump and lighting wiring to avoid false counts.
- Technical Specifications
Presupuesto
- Power Required
- None, passive switch
- Volume Per Pulse
- Determined by the water meter it is fitted to
- Volume per pulse is set by the meter
- Netafim meters ship in different pulse values, so check the register before you scale readings.
Hagamos que funcione para tu proyecto.
En su consulta, incluya la cantidad, el destino de entrega, la zona de cultivo y cualquier requisito de voltaje o enchufe. Las especificaciones, la disponibilidad, el envío y las condiciones de garantía se confirmarán en su presupuesto por escrito.
Conversión de referencia utilizando el tipo de cambio guardado con fecha 15 nov 2026. Los importes convertidos no constituyen una cotización.
SIGUE EXPLORANDO
Ver todos los productosMás posibilidades para tu espacio
Hidroponía y riego
Yield Lab 600W HPS+MH Cool Tube Hood Reflector Grow Light Kit
Referencia de la fuenteEUR 199.27
Hidroponía y riego
Yield Lab 600W HPS+MH Air Cool Tube Reflector Digital Grow Light Kit
Referencia de la fuenteEUR 181.15
Hidroponía y riego
Yield Lab 600w HPS Air Cool Tube Digital Dimming Grow Light Kit
Referencia de la fuenteEUR 172.09
Preguntas y debate
¿Tienes alguna pregunta o algo útil que compartir? Inicia la conversación.