Una forma más brillante de crecer. Venta al por mayor directamente de fábrica. Más de 15 años de experiencia en constante crecimiento.

Este contenido está disponible actualmente en su idioma original.

Hidroponía y riegoConsulta mayorista

Netafim Pulse Reed Switch

Modelo / SKU: 70220-005300

What a Pulse Reed Switch Adds to a Water Meter

Power Required
None, passive switch
Volume Per Pulse
Determined by the water meter it is fitted to
Volume per pulse is set by the meter
Netafim meters ship in different pulse values, so check the register before you scale readings.
Precio de referencia de la fuenteEUR 64.12

Solo a título informativo. Solicite su precio mayorista actual, disponibilidad y condiciones de entrega.

No se requiere ningún pago. Una conversación sobre lo que necesitas.

Soporte directo de fábricaMás de 15 años de experiencia
UNA MIRADA MÁS DETALLADA

Un poco más sobre este producto

What a Pulse Reed Switch Adds to a Water Meter

Product details

  • A mechanical meter counts perfectly well and tells nobody.
  • This register sits on the meter and adds an electrical output.
  • No power is needed on the meter side, because the switch is passive.
  • Reading the Water Meter Pulse Output at the Controller
  • Any controller, datalogger or PLC with a digital input can take it, which is what makes a water meter pulse output so portable across equipment.
  • The controller does the arithmetic: count the pulses, multiply by the volume each pulse represents, and you have consumption.
  • That multiplier is set by the meter rather than by the switch, and Netafim meters are supplied in different pulse values.
  • Check the register on the meter you are fitting, because getting that number wrong scales every reading you log.
  • Two practical notes.
  • Reed contacts are mechanical and they do eventually wear, which is the usual reason one gets replaced rather than a fault in the meter itself.
  • And run the signal pair away from pump and light wiring, since a long unshielded run beside a contactor can pick up false counts.
  • Passive, no power needed: The switch takes nothing on the meter side.
  • The controller supplies the sensing circuit.
  • Volume per pulse is set by the meter: Netafim meters ship in different pulse values, so check the register before you scale readings.
  • A common replacement part: Reed contacts are mechanical and wear, which is usually why one is swapped.
  • Keep the run clean: Route the signal pair away from pump and lighting wiring to avoid false counts.
  • Technical Specifications

Presupuesto

Power Required
None, passive switch
Volume Per Pulse
Determined by the water meter it is fitted to
Volume per pulse is set by the meter
Netafim meters ship in different pulse values, so check the register before you scale readings.

Hagamos que funcione para tu proyecto.

En su consulta, incluya la cantidad, el destino de entrega, la zona de cultivo y cualquier requisito de voltaje o enchufe. Las especificaciones, la disponibilidad, el envío y las condiciones de garantía se confirmarán en su presupuesto por escrito.

Conversión de referencia utilizando el tipo de cambio guardado con fecha 15 nov 2026. Los importes convertidos no constituyen una cotización.

CREZCAMOS JUNTOS

Preguntas y debate

0

¿Tienes alguna pregunta o algo útil que compartir? Inicia la conversación.

SIGUE EXPLORANDO

Más posibilidades para tu espacio

Ver todos los productos
EL COMIENZO DE ALGO BUENO

Vamos a sacar tu proyecto a la luz.

Cuéntenos brevemente qué necesita. Utilizaremos sus datos para preparar una respuesta mayorista adecuada.

Lista de productos

Sin pago. Sin compromiso. Simplemente una conversación útil.