Este contenido está disponible actualmente en su idioma original.
Netafim Backflush Controller, 2 Outputs With DP Sensor, 24VAC, With Mounting Bracket
Modelo / SKU: 00105-006200
Netafim Backflush Controller 24VAC for Mains-Powered Filter Pairs
- Power Source
- 110 or 220 VAC, 50 or 60 Hz, internal transformer to 24VAC
- Dimensions
- 9-1/2 in H x 5-5/8 in L x 3-1/4 in D
- Model
- 31NBCAC2
- Outputs
- 2, 24VAC solenoids
Solo a título informativo. Solicite su precio mayorista actual, disponibilidad y condiciones de entrega.
No se requiere ningún pago. Una conversación sobre lo que necesitas.
Un poco más sobre este producto
Netafim Backflush Controller 24VAC for Mains-Powered Filter Pairs
Product details
- Where a filter pair sits beside the pump house, mains power is the simplest supply for its flushing valves.
- The Netafim 31NBCAC2, item 00105-006200, takes 110 or 220 volts AC through an internal transformer.
- That transformer produces the 24VAC that operates the solenoids on its 2 outputs.
- Its embedded electronic sensor reads the pressure drop across the filters and starts a flush at the chosen set point.
- Netafim allows a set point anywhere from 0.1 to 2.0 bar, with the display in bar or psi.
- A timed interval can run alongside, so whichever comes first starts the sequence.
- The modular board takes plug-in cards of two outputs each, up to 10 in total.
- Automatic disc, sand media and screen filters can all be run from it.
- A mounting bracket comes in the box, and the housing weighs just 1.3 lb.
- The LCD shows flush time, DP set point, actual DP and the flush mode on one screen.
- Programming a Two Filter Flush Controller
- Four keys handle all programming: ENTER, minus, plus and MANUAL.
- Pressing ENTER puts the first field into edit mode, and each further press moves to the next field.
- Flush time per station can be as short as 5 seconds or as long as 6 minutes.
- Hold ENTER for at least 3 seconds to reach the configuration menu.
- There the unit detects how many plug-in boards are fitted and assigns outputs from number 1 upward.
- Answering yes to Main Valve unlocks a pre-dwell between that valve opening and the first filter flushing.
- Pre-dwell steps run from 5 seconds to 6 minutes, so pressure can build before the first station opens.
- A looping limit of 1 to 10 consecutive DP cycles flags a filter that is not coming clean.
- For zero calibration, disconnect both sensor ports so they read atmospheric pressure, then select Yes.
- Pressing MANUAL starts a sequence on demand, and pressing it again ends one in progress.
- 24VAC outputs from mains: Internal transformer accepts 110 or 220 VAC, 50 or 60 Hz.
- Two backflush outputs: Expandable in two-output plug-in cards to a total of 10.
- Embedded DP sensor: Set point 0.1-2.0 bar (1-30 psi), shown in bar or psi.
- Four-key LCD programming: ENTER, minus, plus and MANUAL keys.
- Main valve and pre-dwell: Optional main or pressure sustaining valve with pre-dwell up to 6 minutes.
- Looping alarm: Detects repeated DP cycles past a 1-10 limit.
- Technical Specifications
Presupuesto
- Model
- 31NBCAC2
- Outputs
- 2, 24VAC solenoids
- Power Source
- 110 or 220 VAC, 50 or 60 Hz, internal transformer to 24VAC
- Operating Temperature
- 32-140°F (0-60°C)
- Dimensions
- 9-1/2 in H x 5-5/8 in L x 3-1/4 in D
- Weight
- 1.3 lb
- Two backflush outputs
- Expandable in two-output plug-in cards to a total of 10.
Hagamos que funcione para tu proyecto.
En su consulta, incluya la cantidad, el destino de entrega, la zona de cultivo y cualquier requisito de voltaje o enchufe. Las especificaciones, la disponibilidad, el envío y las condiciones de garantía se confirmarán en su presupuesto por escrito.
Conversión de referencia utilizando el tipo de cambio guardado con fecha 15 nov 2026. Los importes convertidos no constituyen una cotización.
Más posibilidades para tu espacio
Yield Lab Heat Mat Thermostat Temperature Controller
Yield Lab Duct Fan Motor Speed Controller
Preguntas y debate
¿Tienes alguna pregunta o algo útil que compartir? Inicia la conversación.