Growlink Batch TankLINK Temperature Sensor
Modelo / SKU: GL-LINK-TEMPSENSOR
Real-Time Nutrient Reads with the Growlink Batch TankLINK Temperature Sensor
- Power
- 24VDC via TankLINK controller
- Connection
- Screw terminal block (labeled on transmitter)
- Compatible Controller
- Growlink Batch TankLINK (pH, EC, Temp, Level inputs)
- Calibration
- LCD wizard, paired with pH & EC probes
Solo a título informativo. Solicite su precio mayorista actual, disponibilidad y condiciones de entrega.
No se requiere ningún pago. Una conversación sobre lo que necesitas.
Un poco más sobre este producto
Real-Time Nutrient Reads with the Growlink Batch TankLINK Temperature Sensor
Product details
- The Growlink Batch TankLINK Temperature Sensor reads nutrient solution temperature directly inside a batch tank or reservoir.
- The probe ties into the Batch TankLINK controller's screw terminal block.
- It reports continuously at 0.02°F resolution with ±3.6°F (±2°C) accuracy.
- The controller itself operates from 50 to 122°F.
- That range covers the 68–72°F target band most hydroponic crops respond to inside the root zone.
- Drop the probe into calibration solution alongside the pH and EC probes during the LCD wizard.
- It locks in for the run.
- Wiring the TankLINK Temperature Probe into a Live Recirculation Loop
- The sensor handles the temperature input on a controller that already measures pH, EC, and tank level on the same board.
- Pair it with a chiller or in-line heater triggered by the TankLINK.
- The nutrient solution temperature probe data then holds tighter to setpoint through lights-on heat spikes.
- On drain-to-waste schedules, the temperature read alongside EC tells you whether morning-shot solubility issues are temperature-driven.
- That separates a chiller problem from a recipe problem before you adjust the feed.
- Plug-and-play wiring keeps a single-probe swap during teardown to a few minutes.
- No driver shuffling — just the batch tank temperature probe back into the terminal block and a quick recalibrate.
- Most rooms keep one spare on hand for summer runs when reservoir temps climb hardest, particularly in greenhouses without dedicated cooling.
- ±3.6°F (±2°C) Accuracy: Tight enough to confirm the nutrient line stays inside the 68–72°F sweet spot.
- 0.02°F Resolution: Picks up small drifts during lights-on spikes before they widen into a real swing.
- Direct TankLINK Integration: Wires straight into the Batch TankLINK controller's labeled screw terminal block.
- Calibration Wizard Compatible: Drops into the LCD wizard alongside pH and EC for a single calibration pass.
- Plug-and-Play Replacement: Probe swap during teardown takes minutes — terminal block in, recalibrate, run.
- Technical Specifications
Presupuesto
- Connection
- Screw terminal block (labeled on transmitter)
- Compatible Controller
- Growlink Batch TankLINK (pH, EC, Temp, Level inputs)
- Calibration
- LCD wizard, paired with pH & EC probes
- Power
- 24VDC via TankLINK controller
- Direct TankLINK Integration
- Wires straight into the Batch TankLINK controller's labeled screw terminal block.
- Calibration Wizard Compatible
- Drops into the LCD wizard alongside pH and EC for a single calibration pass.
Hagamos que funcione para tu proyecto.
En su consulta, incluya la cantidad, el destino de entrega, la zona de cultivo y cualquier requisito de voltaje o enchufe. Las especificaciones, la disponibilidad, el envío y las condiciones de garantía se confirmarán en su presupuesto por escrito.