Este contenido está disponible actualmente en su idioma original.
Bluelab Pro Controller Wi-Fi
Modelo / SKU: 716489
What the Bluelab Pro Controller Wi-Fi Holds to Setpoint
- Power Supply
- 100-240 VAC, 50/60 Hz, output 5 VDC 1.5 A
- pH Range / Accuracy
- 0.0 - 14.0 / ±0.1 @ 25°C
- Temperature Range
- 0-50°C / 32-122°F
- Probe Cable Length
- 2 m (6 ft)
Solo a título informativo. Solicite su precio mayorista actual, disponibilidad y condiciones de entrega.
No se requiere ningún pago. Una conversación sobre lo que necesitas.
Un poco más sobre este producto
What the Bluelab Pro Controller Wi-Fi Holds to Setpoint
Product details
- Three parameters, and you can run one, two or all three.
- It reads pH across 0.0-14.0 at ±0.1 and conductivity from 0 to 5.0 EC at ±0.1.
- Temperature covers 0-50°C / 32-122°F.
- It then doses to bring each parameter back to the value you programmed.
- Dosing intervals are yours to tune against pump size, tank volume and stock dilution, which keeps a small tank from overshooting.
- It runs on a 100-240 VAC supply, so it is not fussy about the panel it lands next to.
- Every probe is removable and replaceable, on 2 m cables.
- Running an Automatic pH and EC Controller Without Getting Burned
- The safety logic is the part worth paying for.
- High and low alarms sit on each parameter.
- Internal lockouts stop nutrient dosing when a temperature alarm fires.
- An external terminal lets a flow switch kill all dosing when the pump is idle.
- Automatic lockouts also stop dosing outright if the unit detects a fault.
- Set your lockouts before your setpoints.
- The pH probe carries a calibration quality indicator, so you know when it is drifting rather than finding out through a crop.
- Two things to budget for.
- The controller does not include the dosing pumps, so a Peridoser or Solenoid is a separate line item.
- A Bluelab Connect Stick is included.
- Controls pH, conductivity and temperature: Run one parameter or all three, each with its own high and low alarm and its own setpoint.
- Tunable dosing intervals: Match dose length to pump size, tank volume and stock dilution so a small reservoir does not overshoot.
- Layered safety lockouts: Internal, external and automatic fault lockouts stop dosing before a stuck pump becomes a dead crop.
- Replaceable probes on 2 m cables: pH connects by BNC, and every probe comes off individually rather than forcing a whole-unit swap.
- Bluelab Connect Stick included: Data logs and remote monitoring through Bluelab Connect without a separate stick.
- Technical Specifications
Presupuesto
- pH Range / Accuracy
- 0.0 - 14.0 / ±0.1 @ 25°C
- Temperature Range
- 0-50°C / 32-122°F
- Power Supply
- 100-240 VAC, 50/60 Hz, output 5 VDC 1.5 A
- Probe Cable Length
- 2 m (6 ft)
- Connectivity
- Wi-Fi, Bluelab Connect (stick included)
- Dosing Compatibility
- Bluelab Peridoser and Solenoid dosing systems
- Bluelab Connect Stick included
- Data logs and remote monitoring through Bluelab Connect without a separate stick.
Hagamos que funcione para tu proyecto.
En su consulta, incluya la cantidad, el destino de entrega, la zona de cultivo y cualquier requisito de voltaje o enchufe. Las especificaciones, la disponibilidad, el envío y las condiciones de garantía se confirmarán en su presupuesto por escrito.
Conversión de referencia utilizando el tipo de cambio guardado con fecha 15 nov 2026. Los importes convertidos no constituyen una cotización.
Más posibilidades para tu espacio
Yield Lab Heat Mat Thermostat Temperature Controller
Yield Lab Duct Fan Motor Speed Controller
Preguntas y debate
¿Tienes alguna pregunta o algo útil que compartir? Inicia la conversación.