Dieser Inhalt ist derzeit in seiner Originalsprache verfügbar.
TrolMaster Replacement Humidity Sensor for Beta-6
Modell / Artikelnummer: SA-D1
When a Beta-6 Needs a Replacement Humidity Sensor
- Beta-6 input
- 120 volts AC
- Current part number
- SA-H1 (supersedes SA-D1)
- Beta-6 output
- Relay
- Beta-6 weight
- 0.56 kg
Nur zum Vergleich. Fordern Sie Ihren aktuellen Großhandelspreis, die Verfügbarkeit und die Lieferbedingungen an.
Keine Zahlung erforderlich. Ein Gespräch über Ihre Bedürfnisse.
Noch ein paar weitere Informationen zu diesem Produkt
When a Beta-6 Needs a Replacement Humidity Sensor
Product details
- A humidity controller is only as good as the probe hanging off it, and probes age faster than the box they plug into.
- Grow room air is the hard case, because a sensor sitting in condensing humidity for years will read low and keep reading low.
- The usual symptom is a dehumidifier that runs longer than it used to for the same room feel.
- Swapping the probe is the low cost test to run before anyone suspects the controller.
- The Beta-6 itself is a legacy unit in the TrolMaster range, so a spare probe keeps a working controller in service.
- The controller uses a precision sensor in a 16 ft remote probe, switching connected equipment through an outlet.
- This spare now carries the part number SA-H1 rather than SA-D1, which is worth knowing when cross referencing an older unit.
- What the Beta-6 Does With It, Day and Night
- The controller holds two humidity targets and a built in photocell decides which one applies.
- Day and night set points run from 20 to 90 percent relative humidity, with a five point deadband between switching on and off.
- That deadband is what stops a humidifier short cycling around a single number.
- A photocell means the changeover follows room light rather than a clock, so it tracks a lighting schedule automatically.
- It drives either a humidifier or a dehumidifier, not both at once.
- The probe feeds all of that, which is why a drifted sensor shows up as a room that never settles.
- Hang the probe at canopy height and clear of direct airflow from the unit it controls.
- A probe in the dehumidifier's own discharge reads the machine rather than the room.
- Keep the lead out of standing water even though the unit is rated for a normal room.
- The controller weighs about 0.56 kg and measures 275 mm by 87 mm, for anyone planning a wall position.
- What this is: The spare humidity probe alone, not a controller
- For: The TrolMaster Beta-6 day and night humidity controller
- Part code: SA-H1, superseding SA-D1
- Probe lead: The Beta-6 probe is a 16 ft remote lead
- Why replace: An aged probe reads low and overruns equipment
- Controller set points: 20 to 90 percent, separate day and night values
- Deadband: Five points, which prevents short cycling
- Day or night sensing: A built in photocell, not a clock
- Controller electrical: 120 volts in, relay output, 10 A fuse at 250 volts
- Technical Specifications
Spezifikationen
- Current part number
- SA-H1 (supersedes SA-D1)
- Beta-6 input
- 120 volts AC
- Beta-6 output
- Relay
- Beta-6 weight
- 0.56 kg
Lass es uns für dein Projekt zum Laufen bringen
Bitte geben Sie in Ihrer Anfrage die gewünschte Menge, den Lieferort, die Anbaufläche sowie eventuelle Spannungs- oder Steckeranforderungen an. Spezifikationen, Verfügbarkeit, Versand- und Garantiebedingungen werden in Ihrem schriftlichen Angebot bestätigt.
Referenzumrechnung unter Verwendung des gespeicherten Wechselkurses vom 15.11.2026. Die umgerechneten Beträge stellen kein Angebot dar.
Mehr Möglichkeiten für Ihren Raum
Fragen und Diskussion
Haben Sie eine Frage oder möchten Sie etwas Nützliches teilen? Starten Sie das Gespräch.