Dieser Inhalt ist derzeit in seiner Originalsprache verfügbar.
Netafim Pulse Reed Switch
Modell / Artikelnummer: 70220-005300
What a Pulse Reed Switch Adds to a Water Meter
- Power Required
- None, passive switch
- Volume Per Pulse
- Determined by the water meter it is fitted to
- Volume per pulse is set by the meter
- Netafim meters ship in different pulse values, so check the register before you scale readings.
Nur zum Vergleich. Fordern Sie Ihren aktuellen Großhandelspreis, die Verfügbarkeit und die Lieferbedingungen an.
Keine Zahlung erforderlich. Ein Gespräch über Ihre Bedürfnisse.
Noch ein paar weitere Informationen zu diesem Produkt
What a Pulse Reed Switch Adds to a Water Meter
Product details
- A mechanical meter counts perfectly well and tells nobody.
- This register sits on the meter and adds an electrical output.
- No power is needed on the meter side, because the switch is passive.
- Reading the Water Meter Pulse Output at the Controller
- Any controller, datalogger or PLC with a digital input can take it, which is what makes a water meter pulse output so portable across equipment.
- The controller does the arithmetic: count the pulses, multiply by the volume each pulse represents, and you have consumption.
- That multiplier is set by the meter rather than by the switch, and Netafim meters are supplied in different pulse values.
- Check the register on the meter you are fitting, because getting that number wrong scales every reading you log.
- Two practical notes.
- Reed contacts are mechanical and they do eventually wear, which is the usual reason one gets replaced rather than a fault in the meter itself.
- And run the signal pair away from pump and light wiring, since a long unshielded run beside a contactor can pick up false counts.
- Passive, no power needed: The switch takes nothing on the meter side.
- The controller supplies the sensing circuit.
- Volume per pulse is set by the meter: Netafim meters ship in different pulse values, so check the register before you scale readings.
- A common replacement part: Reed contacts are mechanical and wear, which is usually why one is swapped.
- Keep the run clean: Route the signal pair away from pump and lighting wiring to avoid false counts.
- Technical Specifications
Spezifikationen
- Power Required
- None, passive switch
- Volume Per Pulse
- Determined by the water meter it is fitted to
- Volume per pulse is set by the meter
- Netafim meters ship in different pulse values, so check the register before you scale readings.
Lass es uns für dein Projekt zum Laufen bringen
Bitte geben Sie in Ihrer Anfrage die gewünschte Menge, den Lieferort, die Anbaufläche sowie eventuelle Spannungs- oder Steckeranforderungen an. Spezifikationen, Verfügbarkeit, Versand- und Garantiebedingungen werden in Ihrem schriftlichen Angebot bestätigt.
Referenzumrechnung unter Verwendung des gespeicherten Wechselkurses vom 15.11.2026. Die umgerechneten Beträge stellen kein Angebot dar.
Mehr Möglichkeiten für Ihren Raum
Yield Lab 600W HPS+MH Cool Tube Hood Reflector Grow Light Kit
Yield Lab 600W HPS+MH Air Cool Tube Reflector Digital Grow Light Kit
Fragen und Diskussion
Haben Sie eine Frage oder möchten Sie etwas Nützliches teilen? Starten Sie das Gespräch.